Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
125 V |
32 V |
5 A |
Quick Connect |
1 kA |
Push To Reset |
1.161 in (29.5 mm) |
0.563 in (14.3 mm) |
Trip Free |
0.886 in (22.5 mm) |
UL |
1 |
||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
Phoenix Contact |
Thermal Circuit Breaker |
0700040 |
||||||||||||||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
28 V |
1 A |
Printed Circuit Board |
-20 °C (-4 °F) |
Silver |
2 kA |
Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00 |
Reset Button |
0.984 in (25 mm) |
0.504 in (12.8 mm) |
Corrosion Resistant; Moisture Resistant |
e4 |
0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm) |
0.591 in (15 mm) |
CSA; UL; VDE |
1 |
70 °C (158 °F) |
||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
48 V |
4 A |
Solder |
-5 °C (23 °F) |
2 kA |
Reset Type |
Bulk |
0.748 in (19 mm) |
0.575 in (14.6 mm) |
IP40 |
Trip Free |
1.421 in (36.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
10 A |
Screw |
-55 °C (-67 °F) |
2.5 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm) |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
240 V |
16 A |
Screw |
-25 °C (-13 °F) |
10 kA |
3.543 in (90 mm) |
1.394 in (35.4 mm) |
IP20 |
Trip |
3 in (76.2 mm) |
CCC; CE; IMQ; RCM; VDE |
2 |
55 °C (131 °F) |
|||||||||||
Sensata Technologies |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
50 A |
Screw |
3.5 kA |
1 s |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
2.189 in (55.6 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
2.189 x 0.75 x 1.93 in (55.6 x 19.05 x 49.02 mm) |
Trip |
1.93 in (49.02 mm) |
1 |
||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Screw |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Screw |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
Sensata Technologies |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
50 A |
Screw |
3.5 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
2.189 in (55.6 mm) |
0.75 in (19.05 mm) |
Corrosion Resistant; Moisture Resistant |
2.56 in (65.02 mm) |
MIL-C-5809 |
1 |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount-Threaded |
120 V |
28 V |
2 A |
Screw |
800 A |
Standard: MIL-C-5809 |
0.78 in (19.81 mm) |
0.593 in (15.06 mm) |
0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm) |
1.251 in (31.78 mm) |
MS |
1 |
|||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
6 s |
Rated breaking capacity at 50 VDC: 2000 A |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm) |
Series Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1 A |
Lug |
1 kA |
10 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 A |
Rocker |
2.126 in (54 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Tab/Blade |
-30 °C (-22 °F) |
5 kA |
Rocker |
Bulk |
2.126 in (54 mm) |
0.984 in (25 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CSA; UL |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1.5 A |
Quick Connect |
-30 °C (-22 °F) |
15 A |
Rocker |
1.89 in (48 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
1.89 x 0.827 x 1.299 in (48 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
600 V |
100 A |
Screw |
-25 °C (-13 °F) |
65 kA |
Toggle |
5.5 in (139.7 mm) |
4 in (101.6 mm) |
IP40 |
5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm) |
Trip |
3 in (76.2 mm) |
4 |
70 °C (158 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
600 V |
100 A |
Screw |
-25 °C (-13 °F) |
65 kA |
Toggle |
5.5 in (139.7 mm) |
4 in (101.6 mm) |
IP40 |
5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm) |
Trip |
3 in (76.2 mm) |
4 |
70 °C (158 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
600 V |
250 V |
20 A |
Screw |
-25 °C (-13 °F) |
65 kA |
Toggle |
5.5 in (139.7 mm) |
2 in (50.8 mm) |
IP40 |
5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm) |
Trip |
3 in (76.2 mm) |
2 |
70 °C (158 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
1 KV |
100 A |
Screw |
-25 °C (-13 °F) |
65 kA |
Toggle |
7.3 in (185.42 mm) |
5.5 in (139.7 mm) |
IP40 |
7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm) |
Trip |
3.3 in (83.82 mm) |
4 |
70 °C (158 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
Panel Mount |
690 V |
1 KV |
100 A |
Screw |
-25 °C (-13 °F) |
65 kA |
Toggle |
7.3 in (185.42 mm) |
5.5 in (139.7 mm) |
IP40 |
7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm) |
Trip |
3.3 in (83.82 mm) |
4 |
70 °C (158 °F) |
|||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
48 V |
3 A |
Quick Connect |
-5 °C (23 °F) |
2 kA |
Reset Type |
Bulk |
0.606 in (15.4 mm) |
0.535 in (13.6 mm) |
IP40 |
Trip Free |
1.339 in (34 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
32 V |
2 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
0.689 in (17.5 mm) |
Trip |
1.319 in (33.5 mm) |
CCC; CUL; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
415 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.594 in (40.5 mm) |
1.417 in (36 mm) |
IP40 |
Manual On/Off |
1.736 in (44.1 mm) |
CCC; CUL; UL; VDE |
3 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
72 V |
30 A |
Screw |
-55 °C (-67 °F) |
5 kA |
Push-Pull |
1.22 in (31 mm) |
0.709 in (18 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.969 in (50 mm) |
CSA; CUL; UL |
1 |
75 °C (167 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
5 A |
Screw |
-55 °C (-67 °F) |
2 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
230 V |
16 A |
Snap On |
-25 °C (-13 °F) |
5SU1354-7KK16 |
Environmental Characteristics: IP20 |
3.543 in (90 mm) |
1.394 in (35.4 mm) |
Environment/Moisture Resistant |
3.543 x 1.394 x 2.756 in (90 x 35.4 x 70 mm) |
Trip |
2.756 in (70 mm) |
CCC; CE; EAC; IMQ; OVE; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
180 V |
32 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
Toggle Handle |
Bulk |
3.543 in (90 mm) |
2.126 in (54 mm) |
IP20 |
Trip |
2.992 in (76 mm) |
CSA; EN; UL |
3 |
55 °C (131 °F) |
||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
1 |
||||||||||||
Sensata Technologies |
Thermal Circuit Breaker |
7274-2 |
|||||||||||||||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount-Threaded |
120 V |
28 V |
20 A |
Screw |
500 A |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 2000 A |
0.78 in (19.81 mm) |
0.593 in (15.06 mm) |
0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm) |
1.251 in (31.78 mm) |
MS |
1 |
|||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
Thermal Circuit Breaker |
|||||||||||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
16 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
1 |
||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
3 A |
Screw |
2 kA |
10 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm) |
Series Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Through Hole Mount |
250 V |
48 V |
2 A |
Solder |
-20 °C (-4 °F) |
2 kA |
Push To Reset |
1.087 in (27.6 mm) |
0.756 in (19.2 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
0.433 in (11 mm) |
CSA; UL |
1 |
60 °C (140 °F) |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1.5 A |
Quick Connect |
10 s |
Push To Reset |
Series Trip |
1 |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.