Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

TMCP3F13001,5A

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907574

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907574

TMC62C03A

Phoenix Contact

Thermal Magnetic Circuit Breaker

1019912

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMCP2M13000,5A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMCP2F13002,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

1020076

Phoenix Contact

Thermal Magnetic Circuit Breaker

2908226

Phoenix Contact

Thermal Magnetic Circuit Breaker

2908226

2907495

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907495

TMCP3M13006,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC71C30A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

30 A

Snap On

-35 °C (-31 °F)

5 kA

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

TMC71C25A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip Free

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

1019987

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

30 A

Snap On

-35 °C (-31 °F)

5 kA

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

1019974

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

3 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

1019977

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

6 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.37 in (60.2 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

1010284

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

1010289

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

1020061

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

1019997

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

4 A

Screw

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

2908219

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

6 A

Snap On

-35 °C (-31 °F)

Handle

Bulk

3.378 in (85.8 mm)

0.354 in (9 mm)

Trip

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

TMCP1M13000,4A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC73D15A

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907492

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907492

2800855

Phoenix Contact

Thermal Magnetic Circuit Breaker

2800855

1019942

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMCP3F130010,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC62C63A

Phoenix Contact

Thermal Magnetic Circuit Breaker

915742

Phoenix Contact

Thermal Magnetic Circuit Breaker

2800890

Phoenix Contact

Thermal Magnetic Circuit Breaker

2800890

1020082

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMCP2M13003,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC1F11002,5A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC1F11002,5A

CBTM25AM1P

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907501

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907501

TMC83D25A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC83D25A

2907575

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907575

1020040

Phoenix Contact

Thermal Magnetic Circuit Breaker

0902014

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMCP2M130020,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907690

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907690

2907530

Phoenix Contact

Thermal Magnetic Circuit Breaker

2907530

CBTM16AM1P

Phoenix Contact

Thermal Magnetic Circuit Breaker

CBTM16AM1P

TMC1M110012,0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

65 V

12 A

Snap On

-30 °C (-22 °F)

800 A

Rated breaking capacity at 32 VDC: 2500 A

3.78 in (96 mm)

0.492 in (12.5 mm)

IP20; IP30

3.78 x 0.492 x 3.248 in (96 x 12.5 x 82.5 mm)

3.248 in (82.5 mm)

CSA; EAC; EN; UL; VDE

1

60 °C (140 °F)

TMC63C0,5A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC83D05A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC83D05A

1019949

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC71C02A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

1

70 °C (158 °F)

TMC82B30A

Phoenix Contact

Thermal Magnetic Circuit Breaker

TMC82B30A

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.