Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Siemens |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
230 V |
32 A |
Screw And Snap On |
10 kA |
Handle |
3.543 in (90 mm) |
1.417 in (36 mm) |
IP20 |
3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm) |
Trip |
3.031 in (77 mm) |
2 |
70 °C (158 °F) |
|||||||||||
|
Siemens |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
230 V |
13 A |
Screw And Snap On |
6 kA |
Handle |
3.543 in (90 mm) |
1.417 in (36 mm) |
IP20 |
3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm) |
Trip |
3.031 in (77 mm) |
2 |
70 °C (158 °F) |
|||||||||||
|
Siemens |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
230 V |
25 A |
Screw And Snap On |
6 kA |
Handle |
3.543 in (90 mm) |
1.417 in (36 mm) |
IP20 |
3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm) |
Trip |
3.031 in (77 mm) |
2 |
70 °C (158 °F) |
|||||||||||
|
Siemens |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
400 V |
40 A |
Screw And Snap On |
10 kA |
Handle |
3.543 in (90 mm) |
2.835 in (72 mm) |
IP20 |
3.543 x 2.835 x 2.756 in (90 x 72 x 70 mm) |
Trip |
2.756 in (70 mm) |
4 |
70 °C (158 °F) |
|||||||||||
|
Siemens |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
230 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
3.535 in (89.8 mm) |
1.409 in (35.8 mm) |
IP20 |
3.535 x 1.409 x 2.764 in (89.8 x 35.8 x 70.2 mm) |
Trip |
2.764 in (70.2 mm) |
CCC; CE; IMQ |
2 |
45 °C (113 °F) |
Instantaneous |
|||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
Handle |
3.543 in (90 mm) |
0.709 in (18 mm) |
3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm) |
Trip |
2.992 in (76 mm) |
CE; CSA; EN; UL |
1 |
45 °C (113 °F) |
||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
63 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
2.079 in (52.8 mm) |
IP20 |
3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
3 |
||||||||||||
Weidmueller & Kg |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
80 V |
200 mA |
Snap On |
-30 °C (-22 °F) |
200 A |
Rated breaking capacity at 65 VDC: 200 A |
Push To Reset |
3.15 in (80 mm) |
0.984 in (25 mm) |
Corrosion Resistant; Moisture Resistant |
3.15 x 0.984 x 2.087 in (80 x 25 x 53 mm) |
Trip |
2.087 in (53 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
500 V |
100 A |
Snap On |
-25 °C (-13 °F) |
6 kA |
Rated breaking capacity at 500 VDC: 10000 A |
Toggle Handle |
Bulk |
4.252 in (108 mm) |
3.189 in (81 mm) |
IP20 |
Trip |
2.874 in (73 mm) |
EN; IEC |
4 |
70 °C (158 °F) |
|||||||
|
Schneider Electric Sa |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
415 V |
25 A |
Snap On |
-5 °C (23 °F) |
1.5 kA |
Toggle |
3.583 in (91 mm) |
2.835 in (72 mm) |
IP20; IP40 |
3.583 x 2.835 x 2.894 in (91 x 72 x 73.5 mm) |
Trip |
2.894 in (73.5 mm) |
EN/IEC |
4 |
60 °C (140 °F) |
Instantaneous |
||||||||
|
Schneider Electric Sa |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
415 V |
63 A |
Snap On |
-5 °C (23 °F) |
1.5 kA |
Toggle |
3.583 in (91 mm) |
2.835 in (72 mm) |
IP20; IP40 |
3.583 x 2.835 x 2.894 in (91 x 72 x 73.5 mm) |
Trip |
2.894 in (73.5 mm) |
EN/IEC |
4 |
60 °C (140 °F) |
Instantaneous |
||||||||
|
Schneider Electric Sa |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
240 V |
25 A |
Snap On |
-25 °C (-13 °F) |
1.5 kA |
Toggle Handle |
Bulk |
3.583 in (91 mm) |
1.417 in (36 mm) |
IP20; IP40 |
Trip |
2.894 in (73.5 mm) |
EN; IEC |
2 |
60 °C (140 °F) |
|||||||||
|
Schneider Electric Sa |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
240 V |
40 A |
Snap On |
-25 °C (-13 °F) |
1.5 kA |
Toggle Handle |
Bulk |
3.583 in (91 mm) |
1.417 in (36 mm) |
IP20; IP40 |
Trip |
2.894 in (73.5 mm) |
EN; IEC |
2 |
60 °C (140 °F) |
|||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
15 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
1.5 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
||||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
|||||||||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
15 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
||||||||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
15 A |
Snap On |
-25 °C (-13 °F) |
14 kA |
Toggle |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
Trip Free |
1.772 in (45 mm) |
CSA; UL |
3 |
75 °C (167 °F) |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
20 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
2.091 in (53.1 mm) |
2.362 in (60 mm) |
CCC; CSA; UL; VDE |
3 |
75 °C (167 °F) |
Short |
|||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
96 V |
3 A |
Snap On |
-40 °C (-40 °F) |
15 kA |
Toggle |
3.15 in (80 mm) |
2.091 in (53.1 mm) |
IP20 |
Manual On/Off |
2.362 in (60 mm) |
CCC; CE; CSA; IEC; UL; VDE |
3 |
75 °C (167 °F) |
Short |
||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
48 V |
5 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Rated breaking capacity at 400 VAC |
IP20; IP40 |
Trip |
CE; CSA; EN; IEC; UL |
1 |
75 °C (167 °F) |
||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
60 V |
20 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Manual On/Off |
4.134 in (105 mm) |
2.091 in (53.1 mm) |
IP20; IP40 |
Trip |
2.972 in (75.5 mm) |
CSA; EN; IEC; UL |
3 |
75 °C (167 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
DIN Rail Mount |
80 V |
63 A |
Snap On |
-40 °C (-40 °F) |
3 kA |
Handle |
4.188 in (106.38 mm) |
1.376 in (34.95 mm) |
Corrosion/Moisture Resistant |
Series Trip |
2.62 in (66.55 mm) |
CSA, UL |
2 |
85 °C (185 °F) |
|||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-40 °C (-40 °F) |
2 kA |
Toggle Handle |
3.622 in (92 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Series Trip |
1.929 in (49 mm) |
CSA; UL; VDE |
2 |
85 °C (185 °F) |
|||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
415 V |
60 V |
10 A |
Snap On |
-30 °C (-22 °F) |
3 kA |
Toggle |
Bulk |
4.055 in (103 mm) |
0.709 in (18 mm) |
IP20; IP40 |
Trip |
2.835 in (72 mm) |
CCC; CSA; EN; GB; IEC; UL |
1 |
70 °C (158 °F) |
||||||||
|
Idec |
Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
65 V |
20 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle |
2.811 in (71.4 mm) |
0.689 in (17.5 mm) |
IP20 |
Series Trip |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
1 |
60 °C (140 °F) |
|||||||||
Idec |
Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
1 A |
Snap On |
-10 °C (14 °F) |
2.5 kA |
Toggle Handle |
2.811 in (71.4 mm) |
2.067 in (52.5 mm) |
IP20 |
Series Trip |
2.598 in (66 mm) |
CCC; CE; CSA; PSE; TUV; UL |
3 |
60 °C (140 °F) |
|||||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
25 A |
Snap On |
-25 °C (-13 °F) |
50 kA |
Rated breaking capacity max at: 400 VAC |
Button |
3.638 in (92.4 mm) |
1.772 in (45 mm) |
IP00; IP20 |
Trip |
2.65 in (67.3 mm) |
CE; CSA; IEC/EN; UL |
3 |
55 °C (131 °F) |
||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
DIN Rail Mount |
690 V |
2.5 A |
Snap On |
-25 °C (-13 °F) |
150 kA |
Rated breaking capacity at 400 VAC |
Turn Button |
3.638 in (92.4 mm) |
1.772 in (45 mm) |
IP00; IP20 |
3.638 x 1.772 x 2.65 in (92.4 x 45 x 67.3 mm) |
Trip |
2.65 in (67.3 mm) |
CE; CSA; EN; IEC; UL |
3 |
55 °C (131 °F) |
|||||||||
Abb |
Thermal Circuit Breaker |
DIN Rail Mount |
230 V |
20 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Manual On/Off |
2.795 in (71 mm) |
0.689 in (17.5 mm) |
IP20 |
2.795 x 0.689 x 3.622 in (71 x 17.5 x 92 mm) |
3.622 in (92 mm) |
CCC; CSA; IEC; UL; VDE |
1 |
55 °C (131 °F) |
|||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
500 mA |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Rockwell Automation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
600 V |
600 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Manual On/Off |
3.622 in (92 mm) |
1.772 in (45 mm) |
Moisture Resistant; IP2X |
Shunt Trip |
2.618 in (66.5 mm) |
CCC; CE; CSA; CUL; EN; IEC; UL |
3 |
60 °C (140 °F) |
Instantaneous |
||||||||
Eaton Corporation |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
48 V |
250 mA |
Snap On |
-25 °C (-13 °F) |
4.5 kA |
Handle |
Bulk |
3.15 in (80 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.579 in (65.5 mm) |
EN; IEC |
3 |
75 °C (167 °F) |
|||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
2 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
4 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
3.366 in (85.5 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
3 |
60 °C (140 °F) |
||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
25 A |
Snap On |
-20 °C (-4 °F) |
5 kA |
Toggle Handle |
Bulk |
3.366 in (85.5 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
3 |
60 °C (140 °F) |
||||||||||
|
Legrand |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
100 A |
Snap On |
-25 °C (-13 °F) |
25 kA |
Toggle Handle |
Bulk |
4.205 in (106.8 mm) |
4.106 in (104.3 mm) |
Manual On/Off |
3.11 in (79 mm) |
IEC |
4 |
70 °C (158 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-35 °C (-31 °F) |
5 kA |
Toggle Handle |
3.228 in (82 mm) |
2.083 in (52.9 mm) |
Corrosion Resistant; IP20 |
Trip Free |
2.37 in (60.2 mm) |
UL; TUV |
3 |
70 °C (158 °F) |
|||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
20 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
3.535 in (89.8 mm) |
0.693 in (17.6 mm) |
IP20; Sealed |
3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm) |
Trip |
3.008 in (76.4 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
1 |
55 °C (131 °F) |
||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
10 A |
Screw And Snap On |
-25 °C (-13 °F) |
5 kA |
Environmental Characteristics: Sealed |
3.535 in (89.8 mm) |
1.386 in (35.2 mm) |
Environment/Moisture Resistant; IP20 |
3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm) |
Trip |
2.992 in (76 mm) |
CE; CCC; IMQ; RCM; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
2 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
2.079 in (52.8 mm) |
IP20 |
3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
3 |
||||||||||||
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
72 V |
2 A |
Snap On |
-30 °C (-22 °F) |
6 kA |
Interrupting current max at 125 VDC: 10000 A |
Toggle |
2.874 in (73 mm) |
1.417 in (36 mm) |
IP20; IP40 |
2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm) |
Trip |
4.213 in (107 mm) |
CCC; CSA; EN/IEC; GB; UL |
2 |
70 °C (158 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
375 V |
125 A |
Snap On |
-25 °C (-13 °F) |
6 kA |
Toggle |
Bulk |
3.189 in (81 mm) |
3.189 in (81 mm) |
IP20 |
Trip |
2.874 in (73 mm) |
EN; IEC |
3 |
70 °C (158 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
375 V |
100 A |
Snap On |
-25 °C (-13 °F) |
6 kA |
Toggle |
Bulk |
3.189 in (81 mm) |
3.189 in (81 mm) |
IP20 |
Trip |
2.874 in (73 mm) |
EN; IEC |
3 |
70 °C (158 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
375 V |
100 A |
Snap On |
-30 °C (-22 °F) |
10 kA |
Rated breaking capacity at 375 VDC: 15000 A |
Toggle Handle |
Bulk |
3.189 in (81 mm) |
3.189 in (81 mm) |
IP20 |
Trip |
2.874 in (73 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.