230 V Circuit Breaker 23

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

5SU1356-7KK06

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK10

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

5SU1356-7KK10

3.543 in (90 mm)

1.417 in (36 mm)

Environment/Moisture Resistant

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; GOST; IMQ; OVE; VDE

1

55 °C (131 °F)

5SU1354-6KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-7KK16

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

5SU1354-7KK16

Environmental Characteristics: IP20

3.543 in (90 mm)

1.394 in (35.4 mm)

Environment/Moisture Resistant

3.543 x 1.394 x 2.756 in (90 x 35.4 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; IMQ; OVE; VDE

2

55 °C (131 °F)

5SU1354-7KK20

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

20 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; EAC; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3314-6KK12

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

3120-N32A-H7T1-W12LY4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

230 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

5SU1356-7KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1654-7KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3314-6

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

5SV3314-6KK01

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

PXL-C10/1

Eaton Corporation

Magnetic Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

IP20

Trip

2.776 in (70.5 mm)

1

75 °C (167 °F)

5SU1354-6KK25

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-7KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-7KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Snap On

-25 °C (-13 °F)

10 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1354-7KK32

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

32 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK13

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

13 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK25

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV4312-0

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

3.535 in (89.8 mm)

1.409 in (35.8 mm)

IP20

3.535 x 1.409 x 2.764 in (89.8 x 35.8 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; IMQ

2

45 °C (113 °F)

Instantaneous

S201U-K20

Abb

Thermal Circuit Breaker

DIN Rail Mount

230 V

20 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

2.795 in (71 mm)

0.689 in (17.5 mm)

IP20

2.795 x 0.689 x 3.622 in (71 x 17.5 x 92 mm)

3.622 in (92 mm)

CCC; CSA; IEC; UL; VDE

1

55 °C (131 °F)

263174

Eaton Corporation

Thermal Circuit Breaker

230 V

16 A

-25 °C (-13 °F)

6 kA

IP20

Trip

1

55 °C (131 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.