240 V Circuit Breaker 130

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

AP12-1R-41-502

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1RC-62-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

LELH11-1-62-15.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

LELH11-1-62-20.0-91-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

LELH11-1-62F-10.0-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

10 A

Screw

5 kA

Toggle Handle

2.49 in (63.24 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

2

TA45-ABFGP140C0-AZM14

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

14 A

Quick Connect

-10 °C (14 °F)

1 kA

Rocker

1.89 in (48 mm)

0.984 in (25 mm)

IP00; IP40; IP54; IP65

Trip

1.339 in (34 mm)

CSA; SEMKO; SEV; UL; VDE

2

55 °C (131 °F)

EA3-B0-64-475-22A-DF

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

7.5 A

Stud

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL; VDE

3

85 °C (185 °F)

FAZ-D1.5/3-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D15/3-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

3

BAB2020

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

10 kA

Toggle Handle

Bulk

Trip

CSA; UL

2

0916605

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

2 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

QCF1030

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

30 A

Snap On

10 kA

Toggle

Trip

CSA; UL

1

40 °C (104 °F)

QCF2050

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Snap On

10 kA

Toggle Handle

Trip

CSA; UL

2

40 °C (104 °F)

0916606

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

4 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

FAZ-C40/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C50/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Snap On

10 kA

Toggle

Manual On/Off

3

QCF2015

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

10 kA

Toggle Handle

Trip

CSA; UL

2

40 °C (104 °F)

BAB2080

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

80 A

Screw

10 kA

Toggle Handle

Bulk

Trip

CSA; UL

2

BAB3020H

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

10 kA

Toggle Handle

Bulk

Trip

CSA; UL

3

BAB3030H

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

30 A

Screw

10 kA

Toggle Handle

Bulk

Trip

CSA; UL

3

CHF120

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

240 V

20 A

10 kA

Toggle

3 in (76.2 mm)

0.75 in (19.05 mm)

Trip

3 in (76.2 mm)

UL

1

ED3200

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

125 V

200 A

65 kA

Toggle Handle

4.13 in (104.902 mm)

4.13 in (104.902 mm)

Trip

3.38 in (85.852 mm)

UL

3

FAZ-C40/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D35/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

35 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D40/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-K10/1

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

60 V

10 A

Snap On

-40 °C (-40 °F)

10 kA

Toggle Handle

3.15 in (80 mm)

0.689 in (17.5 mm)

IP20; IP40

Trip Free

2.579 in (65.5 mm)

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-S10/1

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

240 V

60 V

10 A

Snap On

-40 °C (-40 °F)

10 kA

Rated breaking capacity at 400 VAC

3.15 in (80 mm)

0.689 in (17.5 mm)

IP20; IP40

3.15 x 0.689 x 2.579 in (80 x 17.5 x 65.5 mm)

Trip

2.579 in (65.5 mm)

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

QBHW2080

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

240 V

80 A

Screw

22 kA

Toggle Handle

Bulk

Trip

CSA; UL

2

QC3015H

Eaton Corporation

Thermal Magnetic Circuit Breaker

240 V

240 V

15 A

10 kA

3.8 in (96.52 mm)

3.2 in (81.28 mm)

3.8 x 3.2 x 4.9 in (96.52 x 81.28 x 124.46 mm)

4.9 in (124.46 mm)

CSA; UL

3

QCGFT2015

Eaton Corporation

Thermal Magnetic Circuit Breaker

240 V

240 V

15 A

10 kA

5.7 in (144.78 mm)

4.4 in (111.76 mm)

5.7 x 4.4 x 3.1 in (144.78 x 111.76 x 78.74 mm)

3.1 in (78.74 mm)

2

QCR1010

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

10 A

Snap On

10 kA

Toggle

Trip

CSA; UL

1

40 °C (104 °F)

QCR3030HT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

30 A

Snap On

10 kA

Toggle Handle

Trip

CSA; UL

3

40 °C (104 °F)

1010284

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

1010289

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.