277 V Circuit Breaker 205

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

AA1-B0-34-630-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

DA3-B0-20-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Toggle Handle

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.165 in (54.99 mm)

CSA; UL

3

85 °C (185 °F)

FAZ-C1.5/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C15/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C2/1-RT-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.134 in (105 mm)

0.697 in (17.7 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

1

75 °C (167 °F)

W68-X2Q12-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

W91-X112-2

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X113-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Stud

-40 °C (-40 °F)

5 kA

150 ms

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

FAZ-C6/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-C3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C1.5/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C15/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-B6/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C20/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D20/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

2

W68-X2Q12-7

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

7 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

FAZ-B15/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

15 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D1.5/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D15/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D30/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

30 A

Snap On

10 kA

Toggle

Manual On/Off

2

102241

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

FAZ-C2/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C4/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C6/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

1020002

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

10 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

2

70 °C (158 °F)

FAZ-C1/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C20/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

20 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C20/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

20 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle Handle

4.134 in (105 mm)

2.091 in (53.1 mm)

IP20; IP40

Trip Free

1.772 in (45 mm)

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

FAZ-C5/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D6/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D6/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

10 kA

Toggle

Manual On/Off

2

1019980

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

10 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.37 in (60.2 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

FAZ-C2/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C8/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

8 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D10/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

FAZ

Toggle

Manual On/Off

1

FAZ-D10/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D25/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-25 °C (-13 °F)

15 kA

3.15 in (80 mm)

1.394 in (35.4 mm)

IP20; IP40

Trip

2.579 in (65.5 mm)

CSA; IEC; UL

2

75 °C (167 °F)

FAZ-D3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

1

167 °C (332.6 °F)

FAZ-D30/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

30 A

Snap On

10 kA

Toggle

Manual On/Off

3

FAZ-D4/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

10 kA

Toggle

Manual On/Off

1

1019986

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip Free

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

278543

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

250 mA

Screw And Snap On

-40 °C (-40 °F)

5 kA

Handle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip

2.858 in (72.6 mm)

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-B1.5/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-B10/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

10 A

Snap On

-40 °C (-40 °F)

10 kA

Toggle Handle

3.15 in (80 mm)

2.067 in (52.5 mm)

Corrosion Resistant; IP20; IP40

Trip Free

2.579 in (65.5 mm)

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

Short

FAZ-B15/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C2/1N

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

IP20

Manual On/Off

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C25/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

25 A

Snap On

10 kA

Toggle

Manual On/Off

3

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.