400 V Circuit Breaker 59

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

409802

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

100 A

Snap On

-25 °C (-13 °F)

25 kA

Toggle Handle

Bulk

4.205 in (106.8 mm)

4.106 in (104.3 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

5SY4102-7

Siemens

Thermal Circuit Breaker

Panel Mount

400 V

2 A

Screw

-25 °C (-13 °F)

10 kA

5SY

Sealed Bat

3.543 in (90 mm)

0.709 in (18 mm)

IP20

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Under Voltage Release

2.756 in (70 mm)

CCC; CUL; EN; GOST; IMQ; UL; VDE

1

45 °C (113 °F)

Standard

5SY4120-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

20 A

Snap On

-25 °C (-13 °F)

5 kA

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; Sealed

3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm)

Trip

3.008 in (76.4 mm)

CCC; CE; IMQ; RCM; UL; VDE

1

55 °C (131 °F)

5SY4210-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Screw And Snap On

-25 °C (-13 °F)

5 kA

Environmental Characteristics: Sealed

3.535 in (89.8 mm)

1.386 in (35.2 mm)

Environment/Moisture Resistant; IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CE; CCC; IMQ; RCM; UL; VDE

2

55 °C (131 °F)

5SY4302-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

3

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

PLSM-C32/4-MW

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.15 in (80 mm)

2.756 in (70 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

4

75 °C (167 °F)

242401

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

DC rated voltage given per pole

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

IEC/EN

2

75 °C (167 °F)

Slow

PL6-C10/4

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

48 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle Handle

Bulk

3.15 in (80 mm)

2.756 in (70 mm)

Trip

2.362 in (60 mm)

4

75 °C (167 °F)

PLSM-B32/3-MW

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

10 kA

Handle

3.15 in (80 mm)

2.067 in (52.5 mm)

Corrosion Resistant; IP20

Trip

2.579 in (65.5 mm)

3

75 °C (167 °F)

5SY6106-7

Infineon Technologies

Thermal Circuit Breaker

DIN Rail And Panel Mount

400 V

6 A

Screw

-25 °C (-13 °F)

5 kA

5SY6106-7

2.992 in (76 mm)

0.709 in (18 mm)

Sealed

2.992 x 0.709 x 3.543 in (76 x 18 x 90 mm)

3.543 in (90 mm)

CCC; CE; GOST; IMQ; KETI; UL; VDE

1

55 °C (131 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.