440 V Circuit Breaker 41

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

25218

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

20 A

Snap On

-25 °C (-13 °F)

10 kA

Rated breaking capacity at 250 VDC: 50000 A

Toggle

2.874 in (73 mm)

2.835 in (72 mm)

Environment/Moisture Resistant

2.874 x 2.835 x 3.189 in (73 x 72 x 81 mm)

Trip

3.189 in (81 mm)

EN; IEC

4

60 °C (140 °F)

60140

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

5 A

Snap On

-30 °C (-22 °F)

6 kA

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Environment/Moisture Resistant; IP20

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN; GB; IEC; UL

2

70 °C (158 °F)

60139

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

4 A

Snap On

-30 °C (-22 °F)

6 kA

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Environment/Moisture Resistant; IP20

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; GB; IEC; UL

2

70 °C (158 °F)

24173

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

4 A

Snap On

-25 °C (-13 °F)

20 kA

24173

Interrupting current max(DC): 15000 A

Toggle

3.189 in (81 mm)

0.709 in (18 mm)

Moisture Resistant

3.189 x 0.709 x 2.874 in (81 x 18 x 73 mm)

Trip

2.874 in (73 mm)

EN; IEC

1

60 °C (140 °F)

60138

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

3 A

Snap On

-30 °C (-22 °F)

6 kA

Interrupting current max(DC): 10000 A

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

IP20; IP40

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN/IEC; GB; UL

2

70 °C (158 °F)

A9F74203

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

3 A

Snap On

-35 °C (-31 °F)

25 kA

Toggle

3.091 in (78.5 mm)

1.417 in (36 mm)

Moisture Resistant; IP20

3.091 x 1.417 x 3.346 in (78.5 x 36 x 85 mm)

Trip

3.346 in (85 mm)

EN; IEC

2

70 °C (158 °F)

A9N18367

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18392

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

500 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Rated breaking capacity at 500 VDC: 10000 A

Toggle Handle

Bulk

4.252 in (108 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

4

70 °C (158 °F)

60137

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

72 V

2 A

Snap On

-30 °C (-22 °F)

6 kA

Interrupting current max at 125 VDC: 10000 A

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

IP20; IP40

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN/IEC; GB; UL

2

70 °C (158 °F)

A9N18369

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

125 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18388

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18469

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-30 °C (-22 °F)

10 kA

Rated breaking capacity at 375 VDC: 15000 A

Toggle Handle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

60 °C (140 °F)

24452

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

20 A

Snap On

-30 °C (-22 °F)

5 kA

Toggle

Bulk

3.189 in (81 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.874 in (73 mm)

CCC; CSA; IEC; UL

2

70 °C (158 °F)

24200

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Moisture Resistant

2.874 x 1.417 x 3.189 in (73 x 36 x 81 mm)

Trip

3.189 in (81 mm)

EN; IEC

2

70 °C (158 °F)

281556

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

440 V

30 A

Screw

-25 °C (-13 °F)

18.5 kA

Rocker Lever

6.512 in (165.4 mm)

3.543 in (90 mm)

IP00; IP10; IP20; IP40; IP66

Trip

2.874 in (73 mm)

CE; IEC; UL

3

70 °C (158 °F)

J7MC-3R-16

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

16 A

Screw

-20 °C (-4 °F)

105 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-E63

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

630 mA

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-1

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-2E5

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

2.5 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-6

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

6.3 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-E4

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

400 mA

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-4

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

4 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-13

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

13 A

Screw

-20 °C (-4 °F)

50 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-13

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

13 A

Screw

-20 °C (-4 °F)

10 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-2E5

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

2.5 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-16

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

16 A

Screw

-20 °C (-4 °F)

10 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-E25

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

250 mA

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-1E6

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1.6 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-10

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

10 A

Screw

-20 °C (-4 °F)

50 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-4

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

4 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-20

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

20 A

Screw

-20 °C (-4 °F)

10 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-E4

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

400 mA

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-E25

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

250 mA

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-6

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

6.3 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-E16

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

160 mA

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-E63

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

630 mA

Screw

-20 °C (-4 °F)

50 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-1

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3P-10

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

10 A

Screw

-20 °C (-4 °F)

15 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-1E6

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1.6 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-20

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

20 A

Screw

-20 °C (-4 °F)

105 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-E16

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

160 mA

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.