600 V Circuit Breaker 14

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

CCP2-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

Panel Mount

600 V

125 V

30 A

200 kA

Toggle Handle

3.1 in (78.74 mm)

1.4 in (35.56 mm)

Manual On/Off

3.9 in (99.06 mm)

UL

2

CCP2-3-60CF

Eaton Corporation

Equipment Leakage Circuit Breaker

600 V

125 V

60 A

200 kA

Toggle Handle

3 in (76.2 mm)

3 in (76.2 mm)

4.5 in (114.3 mm)

UL

3

3VA5340-6EF31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

500 V

400 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

3VA5440-1MU31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

400 A

Screw

-25 °C (-13 °F)

150 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

EA2-B0-24-660-22B-GB

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

600 V

60 A

Stud

-40 °C (-40 °F)

10 kA

Handle

5.78 in (146.81 mm)

2.093 in (53.15 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

2

85 °C (185 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

140M-C2E-B25

Rockwell Automation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

600 V

600 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

3.622 in (92 mm)

1.772 in (45 mm)

Moisture Resistant; IP2X

Shunt Trip

2.618 in (66.5 mm)

CCC; CE; CSA; CUL; EN; IEC; UL

3

60 °C (140 °F)

Instantaneous

CCP2R-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

1.9 in (48.26 mm)

UL

2

CCP2SL-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

Manual On/Off

1.9 in (48.26 mm)

2

CCP2-2-100CF

Eaton Corporation

Equipment Leakage Circuit Breaker

Panel Mount

600 V

125 V

100 A

Toggle Handle

3.6 in (91.44 mm)

2 in (50.8 mm)

Manual On/Off

5.8 in (147.32 mm)

UL

2

CCP2-3-100CF

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

600 V

125 V

100 A

Toggle Handle

3.6 in (91.44 mm)

3 in (76.2 mm)

Manual On/Off

5.8 in (147.32 mm)

UL

3

CCP2SL-3-60CF

Eaton Corporation

Equipment Leakage Circuit Breaker

600 V

125 V

225 A

200 kA

Toggle Handle

8.1 in (205.74 mm)

3 in (76.2 mm)

3.5 in (88.9 mm)

CCC; UL

3

HFD3015

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

600 V

250 V

15 A

Toggle Handle

6 in (152.4 mm)

4.13 in (104.902 mm)

Trip

3.38 in (85.852 mm)

UL

3

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.