100 A Circuit Breaker 20

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

XT1NU3100AFF000XXX

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

347 V

100 A

Snap On

18 kA

5.118 in (130 mm)

3 in (76.2 mm)

5.118 x 3 x 2.756 in (130 x 76.2 x 70 mm)

Trip

2.756 in (70 mm)

CSA; UL

3

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

A9N18367

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

CELB1-1-52-100.-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Series Trip

1.859 in (47.22 mm)

CCC; CSA; TUV; UL

1

85 °C (185 °F)

IELHK111-1-61-100.-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

100 A

Stud

-40 °C (-40 °F)

2 kA

Toggle Handle

2.49 in (63.24 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.859 in (47.22 mm)

CCC; CSA; IEC; TUV; UL

3

85 °C (185 °F)

LELB1-1-53-100.-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

100 A

Screw

50 kA

Toggle

2.49 in (63.24 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

Trip Free

1.859 in (47.22 mm)

CCC; VDE

1

LELHB111-1-52-100.-A1-01-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

300 V

100 A

Stud

-40 °C (-40 °F)

10 kA

Toggle Handle

2.49 in (63.24 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.859 in (47.22 mm)

CCC; CSA; IEC; TUV; UL

3

85 °C (185 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

A9N18392

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

500 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Rated breaking capacity at 500 VDC: 10000 A

Toggle Handle

Bulk

4.252 in (108 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

4

70 °C (158 °F)

CA1-B0-32-810-AG2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

100 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

409802

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

100 A

Snap On

-25 °C (-13 °F)

25 kA

Toggle Handle

Bulk

4.205 in (106.8 mm)

4.106 in (104.3 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

A9N18388

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

70 °C (158 °F)

A9N18469

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

375 V

100 A

Snap On

-30 °C (-22 °F)

10 kA

Rated breaking capacity at 375 VDC: 15000 A

Toggle Handle

Bulk

3.189 in (81 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

3

60 °C (140 °F)

EA1-B4-74-810-FDE-AB

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

1

85 °C (185 °F)

EA1-B4-74-810-GDE-AB

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

100 A

Screw

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

1

85 °C (185 °F)

CCP2-2-100CF

Eaton Corporation

Equipment Leakage Circuit Breaker

Panel Mount

600 V

125 V

100 A

Toggle Handle

3.6 in (91.44 mm)

2 in (50.8 mm)

Manual On/Off

5.8 in (147.32 mm)

UL

2

CCP2-3-100CF

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

600 V

125 V

100 A

Toggle Handle

3.6 in (91.44 mm)

3 in (76.2 mm)

Manual On/Off

5.8 in (147.32 mm)

UL

3

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.