2 A Circuit Breaker 47

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

W28-XQ1A-2

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

2 A

Quick Connect

1 kA

4.5 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

MS3320-2

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2 A

Screw

-55 °C (-67 °F)

2.8 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

2TC2-2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2 A

Screw

2.8 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

0712217

Phoenix Contact

Thermal Circuit Breaker

Panel Mount

250 V

65 V

2 A

Quick Connect

-20 °C (-4 °F)

12 A

Push To Reset

Bulk

0.961 in (24.4 mm)

0.323 in (8.2 mm)

IP40

Trip

1.752 in (44.5 mm)

CCC; CSA; CUL; EAC; UL; VDE

1

60 °C (140 °F)

3120-N321-P7T1-W19DG4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

1410-L210-L2F1-S02-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

2 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

3120-N321-P7T1-W01D-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

5SY4102-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY6102-7

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

400 V

60 V

2 A

Snap On

Manual On/Off

IEC; VDE

1

3RV2011-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

5SY4202-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

CM1-B0-22-420-201-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL

1

85 °C (185 °F)

SU201M-K2

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Interrupting current max at 277 VAC

2.717 in (69 mm)

0.689 in (17.5 mm)

Environment Resistant; IP20; IP40

2.717 x 0.689 x 4.37 in (69 x 17.5 x 111 mm)

Trip

4.37 in (111 mm)

CE; CSA; EN; IEC; UL

1

55 °C (131 °F)

MS26574-2A

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

4435.0029

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

32 V

2 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

0.689 in (17.5 mm)

Trip

1.319 in (33.5 mm)

CCC; CUL; UL; VDE

1

60 °C (140 °F)

FAZ-C2/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

104-PR-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

250 V

48 V

2 A

Solder

-20 °C (-4 °F)

2 kA

Push To Reset

1.087 in (27.6 mm)

0.756 in (19.2 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

0.433 in (11 mm)

CSA; UL

1

60 °C (140 °F)

3120-N32A-H7T1-W12LY4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

230 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

3RV2021-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

MS26574-2

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

1110-F112-P1M1-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

2 A

Quick Connect

-20 °C (-4 °F)

1 kA

ENVIRONMENTAL CHARACTERISTICS: IP40; IP00

Push Button

0.748 in (19 mm)

0.52 in (13.2 mm)

Corrosion Resistant; Moisture Resistant

0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm)

Tease-Free And Trip-Free

1.87 in (47.5 mm)

CBE; CSA; IEC; UL; VDE

1

60 °C (140 °F)

Medium

2C2UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

583-G411-K1M1-A1S0TN-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

200 V

28 V

2 A

Screw

-55 °C (-67 °F)

1 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

1.89 in (48 mm)

0.78 in (19.8 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.496 in (38 mm)

BW; QPL

3

125 °C (257 °F)

5SY4102-7

Siemens

Thermal Circuit Breaker

Panel Mount

400 V

2 A

Screw

-25 °C (-13 °F)

10 kA

5SY

Sealed Bat

3.543 in (90 mm)

0.709 in (18 mm)

IP20

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Under Voltage Release

2.756 in (70 mm)

CCC; CUL; EN; GOST; IMQ; UL; VDE

1

45 °C (113 °F)

Standard

5SY4302-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

3

60137

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

72 V

2 A

Snap On

-30 °C (-22 °F)

6 kA

Interrupting current max at 125 VDC: 10000 A

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

IP20; IP40

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN/IEC; GB; UL

2

70 °C (158 °F)

FAZ-C2/1-RT-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.134 in (105 mm)

0.697 in (17.7 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

1

75 °C (167 °F)

MS26574-2L

Eaton Corporation

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

28 V

2 A

Screw

800 A

Standard: MIL-C-5809

0.78 in (19.81 mm)

0.593 in (15.06 mm)

0.78 x 0.593 x 1.251 in (19.81 x 15.06 x 31.78 mm)

1.251 in (31.78 mm)

MS

1

W91-X112-2

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

3D2UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

W58-XB1A4A-2

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

2 A

Quick Connect

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

FAZ-C2/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

2

0916605

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

2 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

FAZ-C2/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C2/1N

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

IP20

Manual On/Off

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D2/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D2/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

10 kA

Toggle

Manual On/Off

1

KD1-2

Eaton Corporation

Magnetic Circuit Breaker

Panel Mount

2 A

Quick Connect

Push Button

0.63 in (16 mm)

Trip

1.409 in (35.8 mm)

CSA, UL

7277-2-2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

2 A

Screw

7277

Push Button

Trip

0903033

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

2 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1020061

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

TMC71C02A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

1

70 °C (158 °F)

1019995

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

2

70 °C (158 °F)

TMC72C02A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

2

70 °C (158 °F)

0903043

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

24 V

2 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1019973

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

1

70 °C (158 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.