2.5 A Circuit Breaker 18

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

2TC2-21/2

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2.5 A

Screw

2.8 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

MS3320-2-1/2

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

2.5 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

MS3320-21/2

Sensata Technologies

Thermal Circuit Breaker

Panel Mount-Threaded

120 V

2.5 A

Screw

2.8 kA

Push-Pull

0.719 in (18.26 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.719 x 0.593 x 1.03 in (18.26 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

FAZ-C2,5/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

2.5 A

Screw And Snap On

-40 °C (-40 °F)

10 kA

Handle

Bulk

3.15 in (80 mm)

2.126 in (54 mm)

IP20

Trip

2.858 in (72.6 mm)

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

3RV2011-1CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1CA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

10 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

AP12-1-51-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

AP1-1RC-52-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

0.656 in (16.66 mm)

Sealed

Series Trip

1.605 in (40.77 mm)

UL

1

100 °C (212 °F)

GV2ME07

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

2.5 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.118 x 1.772 x 3.504 in (79.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

3600-P10-SI-2.5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

Panel Mount

250 V

65 V

2.5 A

Quick Connect

-30 °C (-22 °F)

1 kA

Push To Reset

1.969 in (50 mm)

0.453 in (11.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

2.008 in (51 mm)

CSA; UL

1

60 °C (140 °F)

3RV1011-1CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP00; IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

IUGN66-1-72-2.50

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

2.5 A

Screw

-40 °C (-40 °F)

1 kA

Toggle

2 in (50.8 mm)

1.515 in (38.48 mm)

Manual On/Off

2.256 in (57.3 mm)

CSA, UL

2

85 °C (185 °F)

PKZM0-2,5

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-25 °C (-13 °F)

150 kA

Rated breaking capacity at 400 VAC

Turn Button

3.638 in (92.4 mm)

1.772 in (45 mm)

IP00; IP20

3.638 x 1.772 x 2.65 in (92.4 x 45 x 67.3 mm)

Trip

2.65 in (67.3 mm)

CE; CSA; EN; IEC; UL

3

55 °C (131 °F)

AP12-1-61F-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1RC-62-252

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

2.5 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

GV2P07

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

2.5 A

Screw And Snap On

-20 °C (-4 °F)

8 kA

Rotary Handle

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.819 in (97 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

J7MC-3P-2E5

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

2.5 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-2E5

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

2.5 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.