3 A Circuit Breaker 46

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

CM-3

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

30 V

3 A

Screw

Manual Reset

2 in (50.8 mm)

1.221 in (31.01 mm)

Corrosion Resistant

Trip Free

1.145 in (29.08 mm)

UL

W28-XQ1A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.625 in (15.88 mm)

0.54 in (13.72 mm)

0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm)

Series Trip

1.535 in (38.99 mm)

CSA; UL; VDE

1

MS3320-3

Defense Logistics Agency

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip Free

1.03 in (26.16 mm)

MIL-C-5809

1

121 °C (249.8 °F)

CA1-B0-54-430-5B1-BA

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

3 A

Screw

-40 °C (-40 °F)

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

1

85 °C (185 °F)

2TC2-3

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

2.5 kA

2TC2

Push-Pull

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

1.03 in (26.16 mm)

5SY6203-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

120 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

2

55 °C (131 °F)

60138

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

3 A

Snap On

-30 °C (-22 °F)

6 kA

Interrupting current max(DC): 10000 A

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

IP20; IP40

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; EN/IEC; GB; UL

2

70 °C (158 °F)

W92-X112-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

MS1-B-10-430-2-1CB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

3 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

3120-N321-P7T1-W19DG4-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

AA1-B0-26-430-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

4435.0019

Schurter Ag

Thermal Circuit Breaker

Panel Mount

277 V

32 V

3 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

0.689 in (17.5 mm)

Trip

1.319 in (33.5 mm)

CCC; CUL; UL; VDE

1

60 °C (140 °F)

2CU3L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

3 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU3L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

3 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

4404.0018

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.606 in (15.4 mm)

0.535 in (13.6 mm)

IP40

Trip Free

1.339 in (34 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

W58-XC4C12A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

3 A

Screw

2 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm)

Series Trip

1.375 in (34.93 mm)

CSA; UL

1

4400.0010

Schurter Ag

Thermal Circuit Breaker

Panel Mount-Threaded

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Button

Bulk

0.748 in (19 mm)

0.433 in (11 mm)

IP40

Trip Free

1.976 in (50.2 mm)

CCC; CSA; IEC; UL; VDE; GB

1

60 °C (140 °F)

5SY4103-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

A9F74203

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

3 A

Snap On

-35 °C (-31 °F)

25 kA

Toggle

3.091 in (78.5 mm)

1.417 in (36 mm)

Moisture Resistant; IP20

3.091 x 1.417 x 3.346 in (78.5 x 36 x 85 mm)

Trip

3.346 in (85 mm)

EN; IEC

2

70 °C (158 °F)

CMB-033-27J6N-B-D/03

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

T21-2-3.00A-02-20BLS

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

32 V

3 A

Solder

-40 °C (-40 °F)

500 A

Toggle

1.375 in (34.93 mm)

1.304 in (33.12 mm)

Trip Free

1.34 in (34.03 mm)

CSA; UL

2

85 °C (185 °F)

1423695-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

3 A

Quick Connect

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

4435.0022

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

3 A

Quick Connect

-30 °C (-22 °F)

2 kA

Rocker

Bulk

1.417 in (36 mm)

1.142 in (29 mm)

IP40

Trip Free

1.736 in (44.1 mm)

CCC; CSA; GB; IEC; UL; VDE

2

60 °C (140 °F)

AP12-1-64F-302

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

3 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle Handle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Sealed

Series Trip

1.78 in (45.21 mm)

UL

2

100 °C (212 °F)

AP12-1-72-302

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

3 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

1.281 in (32.53 mm)

Corrosion Resistant; Sealed

Series Trip

1.78 in (45.21 mm)

2

100 °C (212 °F)

FAZ-C3/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

3 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

MS3320-3V

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

-55 °C (-67 °F)

3.5 kA

Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A

Push Button

0.781 in (19.84 mm)

0.593 in (15.06 mm)

Corrosion Resistant; Moisture Resistant

0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm)

Trip

1.03 in (26.16 mm)

1

121 °C (249.8 °F)

ESX10-103-DC24V-3A-E

E-t-a Elektrotechnische Apparate

Equipment Leakage Circuit Breaker

Panel Mount

24 V

3 A

Quick Connect

0 °C (32 °F)

Manual On/Off

2.362 in (60 mm)

0.484 in (12.3 mm)

Moisture Resistant; IP00; IP30

Trip

2.756 in (70 mm)

CSA; CUL; DNVGL; UL

1

50 °C (122 °F)

ESX10-TB-101-DC24V-3A-E

E-t-a Elektrotechnische Apparate

Equipment Leakage Circuit Breaker

DIN Rail Mount

24 V

3 A

Snap On

-25 °C (-13 °F)

Reset Button

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

Trip

3.268 in (83 mm)

ATEX; CSA; CUL; DNV; IEC; TUV; UKCA; UL

1

60 °C (140 °F)

W68-X2Q12-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

FAZ-C3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

102241

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

FAZ-D3/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-D3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

1

167 °C (332.6 °F)

FAZ-C3/1-NA-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-C3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C3/1N

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

IP20

Manual On/Off

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D3/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

3 A

Snap On

-25 °C (-13 °F)

15 kA

Toggle

4.134 in (105 mm)

2.091 in (53.1 mm)

IP20; IP40

Trip Free

1.772 in (45 mm)

CSA, EN/IEC, UL

3

75 °C (167 °F)

W28-XT1A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

7274-2-3

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

800 A

7274

Push Button

0.75 in (19.05 mm)

0.562 in (14.27 mm)

Water Resistant

0.75 x 0.562 x 1.115 in (19.05 x 14.27 x 28.32 mm)

Trip

1.115 in (28.32 mm)

7274-4-3

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

28 V

3 A

Screw

800 A

7274

Push Button

0.75 in (19.05 mm)

0.562 in (14.27 mm)

Water Resistant

0.75 x 0.562 x 1.115 in (19.05 x 14.27 x 28.32 mm)

Trip

1.115 in (28.32 mm)

0903044

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

24 V

3 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

0903025

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

3 A

Screw

0 °C (32 °F)

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

IP20

3.268 in (83 mm)

CE, UL

50 °C (122 °F)

1019974

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

3 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

0903034

Phoenix Contact

Magnetic Circuit Breaker

DIN Rail Mount

24 V

3 A

Screw

0 °C (32 °F)

100 ms

Bulk

3.15 in (80 mm)

0.492 in (12.5 mm)

Moisture Resistant; IP20

3.15 in (80 mm)

CE; UL

1

50 °C (122 °F)

Fast

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.