Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
24 V |
5 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion/Moisture Resistant; IP00; IP30 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
500 mA |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Equipment Leakage Circuit Breaker |
Panel Mount |
24 V |
3 A |
Quick Connect |
0 °C (32 °F) |
Manual On/Off |
2.362 in (60 mm) |
0.484 in (12.3 mm) |
Moisture Resistant; IP00; IP30 |
Trip |
2.756 in (70 mm) |
CSA; CUL; DNVGL; UL |
1 |
50 °C (122 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Equipment Leakage Circuit Breaker |
DIN Rail Mount |
24 V |
3 A |
Snap On |
-25 °C (-13 °F) |
Reset Button |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
Trip |
3.268 in (83 mm) |
ATEX; CSA; CUL; DNV; IEC; TUV; UKCA; UL |
1 |
60 °C (140 °F) |
|||||||||||
|
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
24 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
450 A |
Push To Reset |
1.15 in (29.21 mm) |
0.36 in (9.14 mm) |
Manual Reset/Off |
0.92 in (23.37 mm) |
SAE |
1 |
85 °C (185 °F) |
|||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
6 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
115 V |
24 V |
10 A |
Stud |
-23 °C (-9.4 °F) |
Manual Reset |
1.272 in (32.3 mm) |
0.831 in (21.1 mm) |
Water Resistant |
0.618 in (15.7 mm) |
SAE |
1 |
65 °C (149 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
24 V |
25 A |
Tab/Blade |
-40 °C (-40 °F) |
450 A |
Push To Reset |
1.15 in (29.21 mm) |
0.36 in (9.14 mm) |
Manual Reset/Off |
0.92 in (23.37 mm) |
SAE |
1 |
85 °C (185 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
115 V |
24 V |
10 A |
Stud |
-23 °C (-9.4 °F) |
Manual Reset |
1.272 in (32.3 mm) |
0.831 in (21.1 mm) |
Water Resistant |
0.618 in (15.7 mm) |
SAE |
1 |
65 °C (149 °F) |
||||||||||||
|
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
24 V |
50 A |
Tab/Blade |
-40 °C (-40 °F) |
750 A |
Push To Reset |
1.15 in (29.21 mm) |
0.36 in (9.14 mm) |
Manual Reset/Off |
0.92 in (23.37 mm) |
SAE |
1 |
85 °C (185 °F) |
|||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
3 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
1 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Thermal Circuit Breaker |
DIN Rail Mount |
24 V |
10 A |
Snap On |
-25 °C (-13 °F) |
Manual On/Off |
Bulk |
3.543 in (90 mm) |
0.484 in (12.3 mm) |
IP30 |
Trip |
3.043 in (77.3 mm) |
CE; CUL; DNVGL; EN; UL |
1 |
50 °C (122 °F) |
||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
3 A |
Screw |
0 °C (32 °F) |
100 ms |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
Moisture Resistant; IP20 |
3.15 in (80 mm) |
CE; UL |
1 |
50 °C (122 °F) |
Fast |
||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
8 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
12 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
10 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
4 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
2 A |
Screw |
0 °C (32 °F) |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
IP20 |
3.268 in (83 mm) |
CE, UL |
50 °C (122 °F) |
|||||||||||||
|
Phoenix Contact |
Magnetic Circuit Breaker |
DIN Rail Mount |
24 V |
6 A |
Screw |
0 °C (32 °F) |
100 ms |
Bulk |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
Moisture Resistant; IP20 |
3.15 in (80 mm) |
CE; UL |
1 |
50 °C (122 °F) |
Fast |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.