250 V Circuit Breaker 9

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

PKZM0-1

Eaton Corporation

Panel Mount

690 V

250 V

1 A

Screw

-25 °C (-13 °F)

150 A

Environmental Characteristics: IP20

Manual On/Off

1.772 in (45 mm)

3.661 in (93 mm)

Corrosion Resistant

Manual On/Off

3.15 in (80 mm)

CE; CSA; EN; IEC; UL

3

55 °C (131 °F)

Short

FAZ-C16/2-NA-DC

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

16 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

DC2DU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

FAZ-C10/2-NA-DC

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

DC2CU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

DC2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

GD3015

Eaton Corporation

Thermal Magnetic Circuit Breaker

480 V

250 V

15 A

-20 °C (-4 °F)

22 kA

0.192 in (4.88 mm)

0.118 in (3 mm)

0.104 in (2.63 mm)

CSA; UL

3

50 °C (122 °F)

HFD3015

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

600 V

250 V

15 A

Toggle Handle

6 in (152.4 mm)

4.13 in (104.902 mm)

Trip

3.38 in (85.852 mm)

UL

3

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.