30 V Circuit Breaker 15

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

CM-3

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

30 V

3 A

Screw

Manual Reset

2 in (50.8 mm)

1.221 in (31.01 mm)

Corrosion Resistant

Trip Free

1.145 in (29.08 mm)

UL

185120F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

120 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

MS25244-10

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

30 V

10 A

Screw

3.5 kA

1 s

Rated breaking capacity at 30 VDC: 6000 A

Push-Pull

1.094 in (27.79 mm)

0.75 in (19.05 mm)

Corrosion/Moisture Resistant

1.094 x 0.75 x 1.49 in (27.79 x 19.05 x 37.85 mm)

Trip Free

1.49 in (37.85 mm)

1

184135F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

135 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

184040F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

184040F-031

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

184040F-041

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

40 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

PDLA-150

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

PDLA-150-I

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

Push Button

3.125 in (79.38 mm)

1.859 in (47.22 mm)

Trip

1.078 in (27.38 mm)

CCC

185150F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

150 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

PDM-40

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

120 V

30 V

40 A

Screw

Push Button

2 in (50.8 mm)

1.159 in (29.44 mm)

Trip

1.145 in (29.08 mm)

UL

PSA-10

Sensata Technologies

Thermal Circuit Breaker

Panel Mount

30 V

10 A

Screw

600 A

Automatic Reset

Trip Free

UL

184090F-011

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

30 V

90 A

Screw

-32 °C (-25.6 °F)

Lever

2.89 in (73.41 mm)

1.9 in (48.26 mm)

Trip

1.44 in (36.58 mm)

SAE; UL

1

82 °C (179.6 °F)

7271-3-10

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

30 V

10 A

Screw

3.5 kA

7271

Rated breaking capacity at 30 VDC: 4000 A

1.375 in (34.93 mm)

0.75 in (19.05 mm)

1.375 x 0.75 x 0.844 in (34.93 x 19.05 x 21.44 mm)

Trip

0.844 in (21.44 mm)

7270-1-5

Texas Instruments

Thermal Circuit Breaker

Panel Mount

120 V

30 V

5 A

Screw

3.5 kA

7270

Rated breaking capacity at 30 VDC: 4000 A

Toggle

1.375 in (34.93 mm)

0.75 in (19.05 mm)

1.375 x 0.75 x 0.844 in (34.93 x 19.05 x 21.44 mm)

Trip

0.844 in (21.44 mm)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.