Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
3 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
15 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
15 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
15 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
2 A |
Quick Connect |
1 kA |
4.5 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
1 A |
Quick Connect |
1 kA |
4.5 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
6 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
8 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; SEV; UL; VDE |
1 |
|||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
12 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
12 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
12 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
20 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
500 mA |
Quick Connect |
1 kA |
4.5 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Tab |
2.5 kA |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Series Trip |
1.693 in (43 mm) |
CE; CSA; CUL; TUV; UL |
1 |
|||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; CSA; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Tab |
2.5 kA |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Series Trip |
1.693 in (43 mm) |
CE; CSA; CUL; TUV; UL |
1 |
|||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
7 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
32 V |
3 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
0.689 in (17.5 mm) |
Trip |
1.319 in (33.5 mm) |
CCC; CUL; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
125 V |
32 V |
5 A |
Quick Connect |
1 kA |
Push To Reset |
1.161 in (29.5 mm) |
0.563 in (14.3 mm) |
Trip Free |
0.886 in (22.5 mm) |
UL |
1 |
||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Screw |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Screw |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
32 V |
2 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
0.689 in (17.5 mm) |
Trip |
1.319 in (33.5 mm) |
CCC; CUL; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
1 |
||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
16 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
1 |
||||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
3 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Manual On/Off |
1.78 in (45.2 mm) |
1 |
60 °C (140 °F) |
||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
12 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
15 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
15 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Manual On/Off |
1.78 in (45.2 mm) |
1 |
60 °C (140 °F) |
||||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
32 V |
3 A |
Solder |
-40 °C (-40 °F) |
500 A |
Toggle |
1.375 in (34.93 mm) |
1.304 in (33.12 mm) |
Trip Free |
1.34 in (34.03 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
10 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Inline/Holder |
32 V |
6 A |
Tab/Blade |
-40 °C (-40 °F) |
150 A |
Push To Reset |
0.787 in (20 mm) |
0.236 in (6 mm) |
Corrosion Resistant; IP00; IP30; IP54 |
Trip Free |
0.945 in (24 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Manual On/Off |
1.78 in (45.2 mm) |
1 |
60 °C (140 °F) |
||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
32 V |
15 A |
Stud |
-40 °C (-40 °F) |
2.5 kA |
Push Button |
2.194 in (55.73 mm) |
1.457 in (37 mm) |
Fluid Resistant, IP66 |
Manual On/Off |
0.728 in (18.5 mm) |
UL |
2 |
85 °C (185 °F) |
|||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
32 V |
20 A |
Stud |
-40 °C (-40 °F) |
2.5 kA |
Push Button |
2.194 in (55.73 mm) |
1.457 in (37 mm) |
Fluid Resistant, IP66 |
Manual On/Off |
0.728 in (18.5 mm) |
UL |
2 |
85 °C (185 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.