48 V Circuit Breaker 43

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

SU201M-K10

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

200 ms

Bulk

4.37 in (111 mm)

0.689 in (17.5 mm)

IP20; IP40

Shunt Trip

2.717 in (69 mm)

CCC; CSA; EN; IEC; UL; VDE

1

55 °C (131 °F)

Instantaneous

4404.0022

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

10 A

Quick Connect

-5 °C (23 °F)

Tin Silver

2 kA

Reset Type

Bulk

0.748 in (19 mm)

0.748 in (19 mm)

IP40

e2

Manual On/Off

1.421 in (36.1 mm)

CCC; CSA; UL; GB; IEC; UL; VDE

1

60 °C (140 °F)

243246

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

6 A

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

2

75 °C (167 °F)

4400.0034

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

16 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.984 in (25 mm)

0.551 in (14 mm)

IP40

Trip Free

1.654 in (42 mm)

CCC; CE; CSA; IEC; UL; VDE

1

60 °C (140 °F)

4400.0008

Schurter Ag

Thermal Circuit Breaker

Panel Mount-Threaded

240 V

48 V

1 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Button

Bulk

0.748 in (19 mm)

0.433 in (11 mm)

IP40

Trip Free

1.976 in (50.2 mm)

CCC; CSA; IEC; UL; VDE; GB

1

60 °C (140 °F)

4404.0001

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

4 A

Quick Connect

-5 °C (23 °F)

Tin Silver

2 kA

Reset Type

Bulk

0.606 in (15.4 mm)

0.535 in (13.6 mm)

IP40

e2

Trip Free

1.339 in (34 mm)

CCC; CSA; GB; IEC; UL; VDE

1

50 °C (122 °F)

SU201M-K1

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

1 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

200 ms

Bulk

4.37 in (111 mm)

0.689 in (17.5 mm)

IP20; IP40

Shunt Trip

2.717 in (69 mm)

CCC; CSA; EN; IEC; UL; VDE

1

55 °C (131 °F)

Instantaneous

SU201M-K6

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

200 ms

Bulk

4.37 in (111 mm)

0.689 in (17.5 mm)

IP20; IP40

Shunt Trip

2.717 in (69 mm)

CCC; CSA; EN; IEC; UL; VDE

1

55 °C (131 °F)

Instantaneous

SU201M-K2

Abb

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Interrupting current max at 277 VAC

2.717 in (69 mm)

0.689 in (17.5 mm)

Environment Resistant; IP20; IP40

2.717 x 0.689 x 4.37 in (69 x 17.5 x 111 mm)

Trip

4.37 in (111 mm)

CE; CSA; EN; IEC; UL

1

55 °C (131 °F)

3-101-228

Schurter Ag

Thermal Circuit Breaker

Through Hole Mount

240 V

48 V

4 A

Solder

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.748 in (19 mm)

0.575 in (14.6 mm)

IP40

Trip Free

1.421 in (36.1 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

4404.0018

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.606 in (15.4 mm)

0.535 in (13.6 mm)

IP40

Trip Free

1.339 in (34 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

FAZ-C2/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

104-PR-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

250 V

48 V

2 A

Solder

-20 °C (-4 °F)

2 kA

Push To Reset

1.087 in (27.6 mm)

0.756 in (19.2 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

0.433 in (11 mm)

CSA; UL

1

60 °C (140 °F)

243304

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

40 A

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

2.067 in (52.5 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

3

75 °C (167 °F)

4400.0010

Schurter Ag

Thermal Circuit Breaker

Panel Mount-Threaded

240 V

48 V

3 A

Quick Connect

-5 °C (23 °F)

2 kA

Reset Button

Bulk

0.748 in (19 mm)

0.433 in (11 mm)

IP40

Trip Free

1.976 in (50.2 mm)

CCC; CSA; IEC; UL; VDE; GB

1

60 °C (140 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

243211

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

160 mA

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

1

75 °C (167 °F)

FAZ-C5/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

QOU225

Schneider Electric Sa

Thermal Circuit Breaker

Panel Mount

240 V

48 V

25 A

10 kA

Rated breaking capacity at 48 VDC: 5000 A

4.05 in (102.87 mm)

1.5 in (38.1 mm)

4.05 x 1.5 x 2.95 in (102.87 x 38.1 x 74.93 mm)

2.95 in (74.93 mm)

CSA; IEC; UL

2

243308

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

250 mA

Snap On

-25 °C (-13 °F)

4.5 kA

Handle

Bulk

3.15 in (80 mm)

2.067 in (52.5 mm)

IP20

Trip

2.579 in (65.5 mm)

EN; IEC

3

75 °C (167 °F)

FAZ-B6/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-B15/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

15 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

102241

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

3

75 °C (167 °F)

FAZ-C5/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-D3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

1

167 °C (332.6 °F)

187060P-03-1

Eaton Corporation

Thermal Circuit Breaker

Panel Mount

48 V

60 A

Screw And Quick Connect

-40 °C (-40 °F)

1.5 kA

Manual Reset

2.271 in (57.68 mm)

Weather Proof; IP66;

2.289 in (58.15 mm)

UL

1

85 °C (185 °F)

278543

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

250 mA

Screw And Snap On

-40 °C (-40 °F)

5 kA

Handle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip

2.858 in (72.6 mm)

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-C2/1N

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

2 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

IP20

Manual On/Off

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C6/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-C6/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C8/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

8 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

102082

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

102164

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

102167

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

242401

Eaton Corporation

Thermal Circuit Breaker

DIN Rail Mount

400 V

48 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

DC rated voltage given per pole

Bulk

3.15 in (80 mm)

1.378 in (35 mm)

IP20

Trip

2.579 in (65.5 mm)

IEC/EN

2

75 °C (167 °F)

Slow

278563

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

25 A

Screw And Snap On

-40 °C (-40 °F)

10 kA

Handle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip

2.858 in (72.6 mm)

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-C1/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

1 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C3/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

0.701 in (17.8 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C3/1N

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

3 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

IP20

Manual On/Off

CCC; CE; CSA; IEC; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C4/1

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Screw

-40 °C (-40 °F)

15 kA

FAZ

Toggle

Manual On/Off

CCC; CSA; UL; VDE

1

75 °C (167 °F)

Short

FAZ-C4/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-D30/1-SP

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

30 A

Snap On

-40 °C (-40 °F)

5 kA

Toggle

Bulk

3.15 in (80 mm)

0.697 in (17.7 mm)

IP20

Trip Free

2.362 in (60 mm)

CSA; UL

1

167 °C (332.6 °F)

PL6-C10/4

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

48 V

10 A

Snap On

-25 °C (-13 °F)

6 kA

Toggle Handle

Bulk

3.15 in (80 mm)

2.756 in (70 mm)

Trip

2.362 in (60 mm)

4

75 °C (167 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.