80 V Circuit Breaker 63

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

AK1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AM2-B0-14-610-201-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

10 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

2 in (50.8 mm)

1.49 in (37.85 mm)

Corrosion/Moisture Resistant

Series Trip

1.817 in (46.15 mm)

CSA; UL

2

85 °C (185 °F)

C21-B0-20-630-41A-E

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

30 A

Stud

-40 °C (-40 °F)

7.5 kA

Rocker

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

1

85 °C (185 °F)

CA1-B0-34-615-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

15 A

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

CA3-P0-D4-825-322-MT

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

250 A

Stud

-40 °C (-40 °F)

10 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

UL

3

85 °C (185 °F)

CA3-P0-D4-922-A21-MT

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

225 A

Stud

-40 °C (-40 °F)

10 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

UL

3

85 °C (185 °F)

GA2-B3-11-663-12-MC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

80 V

63 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

4.188 in (106.38 mm)

1.376 in (34.95 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

2

85 °C (185 °F)

2C2UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

2D4UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

4 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

AA1-B0-34-620-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

20 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-630-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

CA2-B0-34-615-121-R

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

15 A

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

2

85 °C (185 °F)

AM1R-D3-AC07-D-A-5-2

Eaton Corporation

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

2.146 in (54.51 mm)

CSA; UL; TUV

1

85 °C (185 °F)

Medium

5531082

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

80 V

5 A

Snap On

0 °C (32 °F)

1 kA

Push Button

3.15 in (80 mm)

0.492 in (12.5 mm)

Corrosion/Moisture Resistant; IP20; IP40

Tease-Free And Trip-Free

2.697 in (68.5 mm)

CSA; IEC; UL; VDE

1

55 °C (131 °F)

Medium

TMC42-01-5.0A

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

80 V

5 A

Snap On

0 °C (32 °F)

1 kA

Push Button

3.15 in (80 mm)

0.492 in (12.5 mm)

Corrosion/Moisture Resistant; IP20; IP40

Tease-Free And Trip-Free

2.697 in (68.5 mm)

CSA; IEC; UL; VDE

1

55 °C (131 °F)

Medium

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.