Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
7.5 kA |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
1 |
85 °C (185 °F) |
||||||||||
|
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
80 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
2 kA |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
Trip Free |
1.687 in (42.85 mm) |
CCC; VDE |
1 |
85 °C (185 °F) |
|||||||||
Eaton Corporation |
Magnetic Circuit Breaker |
Panel Mount |
6 A |
Quick Connect |
Push Button |
0.63 in (16 mm) |
Trip |
1.409 in (35.8 mm) |
CSA, UL |
||||||||||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
600 A |
Rocker |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
UL; CSA |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
600 A |
Rocker |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
360 A |
Rated breaking capacity at 80 VDC: 600 A |
Rocker |
1.56 in (39.62 mm) |
0.77 in (19.56 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
CSA, UL |
1 |
85 °C (185 °F) |
|||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Illuminated Rocker |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.53 in (38.86 mm) |
UL; CSA |
1 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Push-Pull |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.484 in (37.69 mm) |
UL; CSA |
1 |
85 °C (185 °F) |
||||||||||
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
125 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Push To Reset |
1.375 in (34.93 mm) |
0.68 in (17.27 mm) |
Chemical/Corrosion/Moisture Resistant |
Series Trip |
1.484 in (37.69 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
11 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rocker |
1.89 in (48 mm) |
0.984 in (25 mm) |
IP00; IP40; IP54; IP65 |
Manual On/Off |
1.339 in (34 mm) |
CSA; SEMKO; SEV; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
25 A |
Quick Connect |
1 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
30 A |
Quick Connect |
1 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Fungus Resistant; Moisture Resistant |
2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
Standard |
|||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2.25 in (57.15 mm) |
2 in (50.8 mm) |
Fungus Resistant; Moisture Resistant |
2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
Standard |
|||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
30 A |
Quick Connect |
-40 °C (-40 °F) |
2.5 kA |
2.2 s |
Toggle |
2.25 in (57.15 mm) |
2 in (50.8 mm) |
Fungus Resistant; Moisture Resistant |
2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
3 |
85 °C (185 °F) |
Standard |
|||||||
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
3 |
||||||||||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
30 ms |
Toggle |
2 in (50.8 mm) |
1.5 in (38.1 mm) |
Series Trip |
1.64 in (41.66 mm) |
2 |
85 °C (185 °F) |
|||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
3 A |
Quick Connect |
1 kA |
10 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
28 V |
15 A |
Quick Connect |
-20 °C (-4 °F) |
1 kA |
Push To Reset |
Bulk |
1.26 in (32 mm) |
0.535 in (13.6 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.063 in (27 mm) |
CSA; CUL; UL |
1 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
20 A |
Quick Connect |
-20 °C (-4 °F) |
2 kA |
Rated breaking capacity at 50 VDC: 2500 A |
Push To Reset |
1.142 in (29 mm) |
0.571 in (14.5 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.831 in (46.5 mm) |
CQC; CSA; UL; VDE |
1 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
500 mA |
Quick Connect |
-30 °C (-22 °F) |
5 A |
Rocker |
2.205 in (56 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1.5 A |
Quick Connect |
-30 °C (-22 °F) |
15 A |
Rocker |
2.205 in (56 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
6 A |
Quick Connect |
-30 °C (-22 °F) |
6 A |
Rocker |
2.205 in (56 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
28 V |
2 A |
Quick Connect |
-20 °C (-4 °F) |
20 A |
Rocker |
2.008 in (51 mm) |
0.945 in (24 mm) |
Corrosion Resistant; IP00; IP66 |
Manual On/Off |
1.142 in (29 mm) |
UL; VDE |
1 |
60 °C (140 °F) |
||||||||||
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
Panel Mount |
250 V |
65 V |
2.5 A |
Quick Connect |
-30 °C (-22 °F) |
1 kA |
Push To Reset |
1.969 in (50 mm) |
0.453 in (11.5 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
2.008 in (51 mm) |
CSA; UL |
1 |
60 °C (140 °F) |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
277 V |
28 V |
20 A |
Quick Connect |
-5 °C (23 °F) |
1 kA |
Reset Type |
Bulk |
1.22 in (31 mm) |
0.453 in (11.5 mm) |
IP40 |
Trip Free |
1.772 in (45 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
3 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
1.142 in (29 mm) |
IP40 |
Trip Free |
1.736 in (44.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
1.142 in (29 mm) |
IP40 |
Trip Free |
1.736 in (44.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
20 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
80 V |
1 A |
Quick Connect |
-40 °C (-40 °F) |
1 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL; VDE |
1 |
85 °C (185 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
15 A |
Quick Connect |
1 kA |
Rocker |
0.76 in (19.31 mm) |
0.76 in (19.31 mm) |
Series Trip |
1.535 in (38.99 mm) |
CE; CUL; UL; VDE |
1 |
||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
2 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
1.375 x 0.66 x 1.375 in (34.93 x 16.76 x 34.93 mm) |
Series Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
65 V |
25 A |
Quick Connect |
2.2 s |
Toggle |
Series Trip |
1 |
|||||||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
2 A |
Quick Connect |
-20 °C (-4 °F) |
1 kA |
ENVIRONMENTAL CHARACTERISTICS: IP40; IP00 |
Push Button |
0.748 in (19 mm) |
0.52 in (13.2 mm) |
Corrosion Resistant; Moisture Resistant |
0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm) |
Tease-Free And Trip-Free |
1.87 in (47.5 mm) |
CBE; CSA; IEC; UL; VDE |
1 |
60 °C (140 °F) |
Medium |
||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
72 V |
6 A |
Quick Connect |
-20 °C (-4 °F) |
2 kA |
Push Button |
1.921 in (48.8 mm) |
0.323 in (8.2 mm) |
IP00; IP40 |
0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm) |
Trip Free |
0.961 in (24.4 mm) |
CQC; CSA; EN; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
30 A |
Quick Connect |
10 kA |
Toggle Handle |
5.8 in (147.32 mm) |
3.108 in (78.94 mm) |
Moisture Resistant |
Trip Free |
2.61 in (66.29 mm) |
CSA; CUL; UL; VDE |
3 |
|||||||||||||
|
E-t-a Elektrotechnische Apparate |
Equipment Leakage Circuit Breaker |
Panel Mount |
24 V |
3 A |
Quick Connect |
0 °C (32 °F) |
Manual On/Off |
2.362 in (60 mm) |
0.484 in (12.3 mm) |
Moisture Resistant; IP00; IP30 |
Trip |
2.756 in (70 mm) |
CSA; CUL; DNVGL; UL |
1 |
50 °C (122 °F) |
|||||||||||
|
Nte Electronics |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
1 A |
Quick Connect |
1 kA |
Rated breaking capacity at 50 VDC: 2000 A |
Push Button |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Trip |
1.375 in (34.93 mm) |
CSA; UL |
1 |
|||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
14 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rocker |
1.89 in (48 mm) |
0.984 in (25 mm) |
IP00; IP40; IP54; IP65 |
Trip |
1.339 in (34 mm) |
CSA; SEMKO; SEV; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
15 A |
Quick Connect |
0 °C (32 °F) |
1 kA |
5 s |
Push To Reset |
1.378 in (35 mm) |
0.575 in (14.6 mm) |
Series Trip |
1.22 in (31 mm) |
1 |
60 °C (140 °F) |
||||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
3 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
1.5 in (38.1 mm) |
Fungus Resistant; Moisture Resistant |
2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
Standard |
|||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
20 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Manual On/Off |
1.78 in (45.2 mm) |
1 |
60 °C (140 °F) |
||||||||||
|
Phoenix Contact |
Thermal Circuit Breaker |
Panel Mount |
250 V |
65 V |
10 A |
Quick Connect |
-20 °C (-4 °F) |
80 A |
Push To Reset |
Bulk |
0.961 in (24.4 mm) |
0.323 in (8.2 mm) |
IP40 |
Trip |
1.752 in (44.5 mm) |
CCC; CSA; CUL; EAC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
7 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
1.5 in (38.1 mm) |
Fungus Resistant; Moisture Resistant |
2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
Standard |
|||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
2 A |
Quick Connect |
1 kA |
10 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
Phoenix Contact |
Thermal Circuit Breaker |
Panel Mount |
250 V |
65 V |
6 A |
Quick Connect |
-20 °C (-4 °F) |
48 A |
Push To Reset |
Bulk |
0.961 in (24.4 mm) |
0.323 in (8.2 mm) |
IP40 |
Trip |
1.752 in (44.5 mm) |
CCC; CSA; CUL; EAC; UL; VDE |
1 |
60 °C (140 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.