Siemens Circuit Breaker 138

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

5SY4201-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

5SY4104-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4104-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SY5206-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

500 V

6 A

Screw

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.992 in (90 x 36 x 76 mm)

Trip

2.992 in (76 mm)

2

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

5SY4202-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

5SY4213-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

13 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

3RV1021-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

4 A

Screw And Snap On

6 kA

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

3RV2011-1FA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

5SY4208-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

8 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

3RV2021-4EA10-0DA0

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4PA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

36 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1GD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5340-6EF31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

500 V

400 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

3VA5440-1MU31-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

400 A

Screw

-25 °C (-13 °F)

150 kA

Toggle

9.8 in (248.92 mm)

5.4 in (137.16 mm)

IP40

9.8 x 5.4 x 4.3 in (248.92 x 137.16 x 109.22 mm)

Trip

4.3 in (109.22 mm)

3

70 °C (158 °F)

5SU1356-7KK06

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

6 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK10

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

10 A

Snap On

-25 °C (-13 °F)

5SU1356-7KK10

3.543 in (90 mm)

1.417 in (36 mm)

Environment/Moisture Resistant

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; GOST; IMQ; OVE; VDE

1

55 °C (131 °F)

5SY4301-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

3

3RV1041-4FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP20

6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm)

Trip

6.85 in (174 mm)

3

60 °C (140 °F)

3RV2031-4UA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.882 in (140 x 55 x 149.4 mm)

Trip

5.882 in (149.4 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2031-4VA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

45 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2031-4WA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

52 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2031-4XA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

59 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

5SJ4106-6HG40

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

60 V

6 A

Snap On

-25 °C (-13 °F)

Interrupting current max: 14000 A as per UL/CSA

Handle

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; IP40; Sealed

3.535 x 0.693 x 3.031 in (89.8 x 17.6 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

1

55 °C (131 °F)

5SU1354-6KK10

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

10 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1354-6KK16

Siemens

Thermal Circuit Breaker

Panel Mount

240 V

16 A

Screw

-25 °C (-13 °F)

10 kA

3.543 in (90 mm)

1.394 in (35.4 mm)

IP20

Trip

3 in (76.2 mm)

CCC; CE; IMQ; RCM; VDE

2

55 °C (131 °F)

3RV1341-4JC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

63 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP20

6.496 x 2.756 x 6.85 in (165 x 70 x 174 mm)

Trip

6.85 in (174 mm)

3

60 °C (140 °F)

3RV2011-1DA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1JA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-4AA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-4EA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2121-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

2.559 in (65 mm)

IP20

3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm)

Relay Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

5SU1354-7KK16

Siemens

Thermal Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

5SU1354-7KK16

Environmental Characteristics: IP20

3.543 in (90 mm)

1.394 in (35.4 mm)

Environment/Moisture Resistant

3.543 x 1.394 x 2.756 in (90 x 35.4 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; IMQ; OVE; VDE

2

55 °C (131 °F)

5SU1354-7KK20

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

20 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SU1356-6KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Snap On

-25 °C (-13 °F)

6 kA

Bulk

3.543 in (90 mm)

1.417 in (36 mm)

IP20

Trip

3.031 in (77 mm)

CCC; CE; EAC; IMQ; RCM; VDE

2

55 °C (131 °F)

5SU1356-7KK16

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

16 A

Screw And Snap On

6 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 3.031 in (90 x 36 x 77 mm)

Trip

3.031 in (77 mm)

2

70 °C (158 °F)

5SV3314-6KK12

Siemens

Equipment Leakage Circuit Breaker

DIN Rail Mount

230 V

40 A

Screw And Snap On

10 kA

Handle

3.543 in (90 mm)

1.417 in (36 mm)

IP20

3.543 x 1.417 x 2.756 in (90 x 36 x 70 mm)

Trip

2.756 in (70 mm)

2

70 °C (158 °F)

5SY4204-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

2

5SY6332-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

180 V

32 A

Snap On

-25 °C (-13 °F)

5 kA

Toggle Handle

Bulk

3.543 in (90 mm)

2.126 in (54 mm)

IP20

Trip

2.992 in (76 mm)

CSA; EN; UL

3

55 °C (131 °F)

3RV1011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

3RV1031-4HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

50 A

Snap On

-20 °C (-4 °F)

4 kA

5.512 in (140 mm)

2.165 in (55 mm)

IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.