Electric Fuse Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0612R9151-32

Bel Fuse

Electric Fuse

Through Hole Mount

125 V

15 A

Pin Wire

3.377 kJ

-55 °C (-67 °F)

10 kA

30 s

Bulk

0.272 in (6.9 mm)

125 V

0.236 x 1.26 in (6 x 32 mm)

1.28 in (32.5 mm)

CSA; CUL; PSE; UL

125 °C (257 °F)

Slow

0659C2500-12

Bel Fuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

28.1 J

-55 °C (-67 °F)

Nickel

1.5 kA

Bulk

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CQC; CUL; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0678-9300-M2

Bel Fuse

Electric Fuse

30 A

-55 °C (-67 °F)

Matte Tin

100 A

Tape And Reel

0.386 in (9.8 mm)

0.12 in (3.05 mm)

e3

250 V

3912

0.386 x 0.12 x 0.12 in (9.8 x 3.05 x 3.05 mm)

0.12 in (3.05 mm)

UL

125 °C (257 °F)

Medium

0678H9300-02

Bel Fuse

Electric Fuse

Surface Mount

250 V

125 V

30 A

Wraparound

2 kJ

-55 °C (-67 °F)

Silver

100 A

1 m

Rated Breaking Capacity at 125 VDC: 1000 A

Tape And Reel, 13 inch

0.386 in (9.8 mm)

0.12 in (3.05 mm)

e4

250 V

3912

0.12 in (3.05 mm)

AEC-Q200; CUL; CE; UL

125 °C (257 °F)

0679H1250-05

Bel Fuse

Electric Fuse

Surface Mount

350 V

72 V

1.25 A

Wraparound

210 mJ

-55 °C (-67 °F)

Silver

50 A

5 s

Rated Breaking Capacity at 72 VDC: 100 A

0.22

Tape And Reel, 13 inch

0.24 in (6.1 mm)

0.1 in (2.54 mm)

e4

72 V

10 ms

2410

0.24 x 0.1 x 0.1 in (6.1 x 2.54 x 2.54 mm)

0.1 in (2.54 mm)

AEC-Q200; TUV; CUL; UL

125 °C (257 °F)

Very Fast

0680-0500-01

Bel Fuse

Electric Fuse

Surface Mount

125 V

125 V

500 mA

Wraparound

280 mJ

-55 °C (-67 °F)

Nickel/Palladium

50 A

20 ms

Tape And Reel, 7 inch

0.053 in (1.35 mm)

0.1 in (2.54 mm)

e4

2410

0.1 in (2.54 mm)

CE; CSA; CUL; UL

125 °C (257 °F)

Slow

0691-0063-02

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

1 mJ

-55 °C (-67 °F)

Matte Tin

50 A

Ammo Pack

0.329 in (8.35 mm)

e3

250 V

20 ms

Micro

0.329 x 0.303 in (8.35 x 7.7 mm)

0.303 in (7.7 mm)

CSA; CUL; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0691-0080-02

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

80 mA

Pin Wire

2 mJ

-55 °C (-67 °F)

Matte Tin

50 A

Ammo Pack

0.329 in (8.35 mm)

e3

250 V

20 ms

Micro

0.329 x 0.303 in (8.35 x 7.7 mm)

0.303 in (7.7 mm)

CSA; CUL; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0697-0080-01

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

80 mA

Pin Wire

10 mJ

-55 °C (-67 °F)

Matte Tin

35 A

Bulk

0.329 in (8.35 mm)

0.157 in (4 mm)

e3

250 V

20 ms

Micro

0.329 x 0.157 x 0.303 in (8.35 x 4 x 7.7 mm)

0.303 in (7.7 mm)

CCC; CUL; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0697A2000-05

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

63 V

2 A

Pin Wire

26 J

-55 °C (-67 °F)

Matte Tin

100 A

Bulk

0.329 in (8.35 mm)

0.157 in (4 mm)

e3

20 ms

Micro

0.329 x 0.157 x 0.307 in (8.35 x 4 x 7.8 mm)

0.307 in (7.8 mm)

CCC, CQC, CUL, IEC60127-3, PSE, UL, VDE

125 °C (257 °F)

Time Lag

0877002.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

24.6 J

-55 °C (-67 °F)

Tin

35 A

24.6

Bulk

0.142 in (3.6 mm)

e3

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.394 in (10 mm)

IEC; UL; VDE

125 °C (257 °F)

Slow

0ADEC9100-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

100 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

0AKK-K350-BA

Bel Fuse

Electric Fuse

Inline/Holder

1 KV

350 A

Tab/Blade

29 kJ

-40 °C (-40 °F)

Tin

50 kA

Bulk

2.913 in (74 mm)

1.772 in (45 mm)

e3

0.984 in (25 mm)

125 °C (257 °F)

Fast

0ATO003.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

1 kA

100 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0ATO015.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

340 J

-40 °C (-40 °F)

1 kA

100 ms

Box

0.752 in (19.1 mm)

0.201 in (5.1 mm)

0.484 in (12.3 mm)

CSA; UL

125 °C (257 °F)

0CBO075.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

75 A

Tab/Blade

10 kA

0.812 in (20.62 mm)

1.623 in (41.23 mm)

Fast

0CCK075.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

75 A

Tab/Blade

10 kA

1.06 in (26.92 mm)

4.46 in (113.28 mm)

Time Delay

0CNN035.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

35 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

0FLM001T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

1 A

End Cap

10 kA

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

0FLM005T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

5 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

0FLQ003.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

3 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0FLQ006.T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

6 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

0HEV050.ZXBD2

Littelfuse

Electric Fuse

Inline/Holder

275 V

50 A

Tab/Blade

1.495 kJ

-40 °C (-40 °F)

Silver

10 kA

50 ms

e4

1.531 in (38.9 mm)

CSA; UL

125 °C (257 °F)

0JTD004.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

0JTD090.VXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

90 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

Indicator

2.626 in (66.7 mm)

CSA; UL

Time Delay

0TLS035.TXLS

Littelfuse

Electric Fuse

Inline/Holder

170 V

35 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS060.TXL

Littelfuse

Electric Fuse

Inline/Holder

170 V

60 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS060.TXLS

Littelfuse

Electric Fuse

Inline/Holder

170 V

60 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0TLS060.TXV

Littelfuse

Electric Fuse

Inline/Holder

170 V

60 A

Tab/Blade

Silver

100 kA

Bulk

0.563 in (14.3 mm)

e4

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

17037-G

Mersen S A

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

Silver

80 kA

Box

0.563 in (14.3 mm)

e4

690 V

0.563 x 2.008 in (14.3 x 51 mm)

2.008 in (51 mm)

IEC; NFC; UNE

170M2613

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

80 A

Tab/Blade

310 J

200 kA

Box

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm)

2.008 in (51 mm)

CE; CSA; DIN 43653; IEC; UL

170M3242

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

1.3 KV

125 A

Tab/Blade

1.45 kJ

100 kA

Rated Breaking Capacity at 1300 VDC: 100000 A

Box

3.15 in (80 mm)

1.772 in (45 mm)

Indicator

3.15 x 1.772 x 1.772 in (80 x 45 x 45 mm)

1.772 in (45 mm)

CE; DIN 43653; IEC; UL

170M3619

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

400 A

Tab/Blade

15 kJ

200 kA

Rated Breaking Capacity at 700 VDC: 200000 A

Box

1.969 in (50 mm)

1.772 in (45 mm)

1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm)

1.772 in (45 mm)

CE; IEC; UL

170M3817D

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

315 A

Tab/Blade

52 kJ

200 kA

2.52 in (64 mm)

1.575 in (40 mm)

Indicator

2.52 x 1.575 x 2.677 in (64 x 40 x 68 mm)

2.677 in (68 mm)

CE; CSA; IEC; UL

170M4410

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

315 A

Tab/Blade

6.2 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4417

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 A

Tab/Blade

69.5 kJ

200 kA

Box

2.087 in (53 mm)

2.087 in (53 mm)

Indicator

2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm)

1.969 in (50 mm)

CE; IEC; UL

170M4488

Eaton Corporation

Electric Fuse

Inline/Holder

1.3 KV

160 A

End Cap

1.9 kJ

100 kA

2.913 in (74 mm)

2.087 in (53 mm)

Indicator

2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

170M4612

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

700 V

400 A

Tab/Blade

13.5 kJ

200 kA

Rated Breaking Capacity at 700 VDC: 200000 A

Box

2.087 in (53 mm)

1.969 in (50 mm)

2.087 x 1.969 x 2.087 in (53 x 50 x 53 mm)

2.087 in (53 mm)

CE; IEC; UL

170M6790

Eaton Corporation

Electric Fuse

170M8612

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

1.25 kA

575 kJ

150 kA

170M

3.161 in (80.3 mm)

2.913 in (74 mm)

Indicator

3.161 x 2.913 x 3.622 in (80.3 x 74 x 92 mm)

3.622 in (92 mm)

CE; IEC; UL

179020.2,5

Siba

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

11 J

35 A

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BEAB, SEMKO, UL, VDE

Very Fast

179120.2

Siba

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

20 J

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

SEMKO, UL, VDE

Time Lag

189140.3,15

Siba

Electric Fuse

Inline/Holder

500 V

400 V

3.15 A

End Cap

37 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

20111000001P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20C14X51GI

Altech

Electric Fuse

Inline/Holder

690 V

20 A

End Cap

80 kA

Bulk

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CE; IEC

Slow

313003P

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

Tin

100 A

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Slow

3402.0049.24

Schurter Ag

Electric Fuse

Surface Mount

63 V

63 V

125 mA

Wraparound

1.1 mJ

-40 °C (-40 °F)

Tin

50 A

0.0011

Tape And Reel, 13 inch

0.291 in (7.4 mm)

0.122 in (3.1 mm)

e3

10 ms

0.291 x 0.122 in (7.4 x 3.1 mm)

0.291 x 0.122 x 0.102 in (7.4 x 3.1 x 2.6 mm)

0.102 in (2.6 mm)

CUL; UL

125 °C (257 °F)

Very Fast

3403.0012.24

Schurter Ag

Electric Fuse

Surface Mount

250 V

250 V

400 mA

Wraparound

20 mJ

-55 °C (-67 °F)

Tin

100 A

Tape And Reel, 13 inch

0.433 in (11 mm)

0.181 in (4.6 mm)

e3

1 ms

0.433 x 0.181 in (11 x 4.6 mm)

0.433 x 0.181 x 0.154 in (11 x 4.6 x 3.9 mm)

0.154 in (3.9 mm)

CUL; UL; VDE

125 °C (257 °F)

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.