Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
125 V |
15 A |
Pin Wire |
3.377 kJ |
-55 °C (-67 °F) |
10 kA |
30 s |
Bulk |
0.272 in (6.9 mm) |
125 V |
0.236 x 1.26 in (6 x 32 mm) |
1.28 in (32.5 mm) |
CSA; CUL; PSE; UL |
125 °C (257 °F) |
Slow |
|||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
28.1 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Bulk |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CQC; CUL; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Bel Fuse |
Electric Fuse |
30 A |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Tape And Reel |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
e3 |
250 V |
3912 |
0.386 x 0.12 x 0.12 in (9.8 x 3.05 x 3.05 mm) |
0.12 in (3.05 mm) |
UL |
125 °C (257 °F) |
Medium |
||||||||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
250 V |
125 V |
30 A |
Wraparound |
2 kJ |
-55 °C (-67 °F) |
Silver |
100 A |
1 m |
Rated Breaking Capacity at 125 VDC: 1000 A |
Tape And Reel, 13 inch |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
e4 |
250 V |
3912 |
0.12 in (3.05 mm) |
AEC-Q200; CUL; CE; UL |
125 °C (257 °F) |
|||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
350 V |
72 V |
1.25 A |
Wraparound |
210 mJ |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Rated Breaking Capacity at 72 VDC: 100 A |
0.22 |
Tape And Reel, 13 inch |
0.24 in (6.1 mm) |
0.1 in (2.54 mm) |
e4 |
72 V |
10 ms |
2410 |
0.24 x 0.1 x 0.1 in (6.1 x 2.54 x 2.54 mm) |
0.1 in (2.54 mm) |
AEC-Q200; TUV; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
500 mA |
Wraparound |
280 mJ |
-55 °C (-67 °F) |
Nickel/Palladium |
50 A |
20 ms |
Tape And Reel, 7 inch |
0.053 in (1.35 mm) |
0.1 in (2.54 mm) |
e4 |
2410 |
0.1 in (2.54 mm) |
CE; CSA; CUL; UL |
125 °C (257 °F) |
Slow |
||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
63 mA |
Pin Wire |
1 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Ammo Pack |
0.329 in (8.35 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
CSA; CUL; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
80 mA |
Pin Wire |
2 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Ammo Pack |
0.329 in (8.35 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
CSA; CUL; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
80 mA |
Pin Wire |
10 mJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Bulk |
0.329 in (8.35 mm) |
0.157 in (4 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.157 x 0.303 in (8.35 x 4 x 7.7 mm) |
0.303 in (7.7 mm) |
CCC; CUL; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
63 V |
2 A |
Pin Wire |
26 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Bulk |
0.329 in (8.35 mm) |
0.157 in (4 mm) |
e3 |
20 ms |
Micro |
0.329 x 0.157 x 0.307 in (8.35 x 4 x 7.8 mm) |
0.307 in (7.8 mm) |
CCC, CQC, CUL, IEC60127-3, PSE, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Pin Wire |
24.6 J |
-55 °C (-67 °F) |
Tin |
35 A |
24.6 |
Bulk |
0.142 in (3.6 mm) |
e3 |
250 V |
0.142 x 0.394 in (3.6 x 10 mm) |
0.394 in (10 mm) |
IEC; UL; VDE |
125 °C (257 °F) |
Slow |
|||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
10 A |
End Cap |
100 J |
-55 °C (-67 °F) |
Silver |
30 kA |
10 s |
Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current |
Bulk |
0.252 in (6.4 mm) |
e4 |
500 V |
0.236 x 1.26 in (6 x 32 mm) |
1.252 in (31.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
|||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
350 A |
Tab/Blade |
29 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
1.772 in (45 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
3 A |
Tab/Blade |
7.4 J |
-40 °C (-40 °F) |
1 kA |
100 ms |
Box |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
0.484 in (12.3 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
15 A |
Tab/Blade |
340 J |
-40 °C (-40 °F) |
1 kA |
100 ms |
Box |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
0.484 in (12.3 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
75 A |
Tab/Blade |
10 kA |
0.812 in (20.62 mm) |
1.623 in (41.23 mm) |
Fast |
||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
75 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
4.46 in (113.28 mm) |
Time Delay |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
48 V |
35 A |
Tab/Blade |
2.5 kA |
3.181 in (80.8 mm) |
48 V |
3.18 in (80.77 mm) |
UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1 A |
End Cap |
10 kA |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
3 A |
End Cap |
Nickel |
10 kA |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
6 A |
End Cap |
Nickel |
10 kA |
0.406 in (10.31 mm) |
500 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
275 V |
50 A |
Tab/Blade |
1.495 kJ |
-40 °C (-40 °F) |
Silver |
10 kA |
50 ms |
e4 |
1.531 in (38.9 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.811 in (20.6 mm) |
Indicator |
2.252 in (57.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
90 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.126 in (28.6 mm) |
Indicator |
2.626 in (66.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
35 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
60 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
60 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
60 A |
Tab/Blade |
Silver |
100 kA |
Bulk |
0.563 in (14.3 mm) |
e4 |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
690 V |
20 A |
End Cap |
Silver |
80 kA |
Box |
0.563 in (14.3 mm) |
e4 |
690 V |
0.563 x 2.008 in (14.3 x 51 mm) |
2.008 in (51 mm) |
IEC; NFC; UNE |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
80 A |
Tab/Blade |
310 J |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.3 KV |
125 A |
Tab/Blade |
1.45 kJ |
100 kA |
Rated Breaking Capacity at 1300 VDC: 100000 A |
Box |
3.15 in (80 mm) |
1.772 in (45 mm) |
Indicator |
3.15 x 1.772 x 1.772 in (80 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
400 A |
Tab/Blade |
15 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
1.969 in (50 mm) |
1.772 in (45 mm) |
1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; IEC; UL |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
315 A |
Tab/Blade |
52 kJ |
200 kA |
2.52 in (64 mm) |
1.575 in (40 mm) |
Indicator |
2.52 x 1.575 x 2.677 in (64 x 40 x 68 mm) |
2.677 in (68 mm) |
CE; CSA; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
315 A |
Tab/Blade |
6.2 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 A |
Tab/Blade |
69.5 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
160 A |
End Cap |
1.9 kJ |
100 kA |
2.913 in (74 mm) |
2.087 in (53 mm) |
Indicator |
2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
400 A |
Tab/Blade |
13.5 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
2.087 in (53 mm) |
1.969 in (50 mm) |
2.087 x 1.969 x 2.087 in (53 x 50 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
|||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
1.25 kA |
575 kJ |
150 kA |
170M |
3.161 in (80.3 mm) |
2.913 in (74 mm) |
Indicator |
3.161 x 2.913 x 3.622 in (80.3 x 74 x 92 mm) |
3.622 in (92 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
11 J |
35 A |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
BEAB, SEMKO, UL, VDE |
Very Fast |
|||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
20 J |
Nickel |
35 A |
Bulk |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
SEMKO, UL, VDE |
Time Lag |
||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
400 V |
3.15 A |
End Cap |
37 J |
Nickel |
1.5 kA |
Bulk |
0.25 in (6.35 mm) |
500 V |
20 ms |
0.248 x 1.26 in (6.3 x 32 mm) |
1.252 in (31.8 mm) |
UL |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
2 J |
-25 °C (-13 °F) |
80 A |
5 ms |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
Indicator |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CUL; UL |
70 °C (158 °F) |
Medium Time Lag |
|||||||||||
|
Altech |
Electric Fuse |
Inline/Holder |
690 V |
20 A |
End Cap |
80 kA |
Bulk |
0.551 in (14 mm) |
0.551 x 2.008 in (14 x 51 mm) |
2.008 in (51 mm) |
CE; IEC |
Slow |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
200 J |
Tin |
100 A |
0.25 in (6.35 mm) |
e3 |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; METI; PSE; UL |
Slow |
||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
63 V |
63 V |
125 mA |
Wraparound |
1.1 mJ |
-40 °C (-40 °F) |
Tin |
50 A |
0.0011 |
Tape And Reel, 13 inch |
0.291 in (7.4 mm) |
0.122 in (3.1 mm) |
e3 |
10 ms |
0.291 x 0.122 in (7.4 x 3.1 mm) |
0.291 x 0.122 x 0.102 in (7.4 x 3.1 x 2.6 mm) |
0.102 in (2.6 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
250 V |
400 mA |
Wraparound |
20 mJ |
-55 °C (-67 °F) |
Tin |
100 A |
Tape And Reel, 13 inch |
0.433 in (11 mm) |
0.181 in (4.6 mm) |
e3 |
1 ms |
0.433 x 0.181 in (11 x 4.6 mm) |
0.433 x 0.181 x 0.154 in (11 x 4.6 x 3.9 mm) |
0.154 in (3.9 mm) |
CUL; UL; VDE |
125 °C (257 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.