Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
200 A |
Tab/Blade |
159 kJ |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
600 V |
Indicator |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
6 KV |
100 mA |
End Cap |
35 A |
Bulk |
0.315 in (8 mm) |
6 KV |
30 ms |
0.315 x 4.724 in (8 x 120 mm) |
4.724 in (120 mm) |
DIN |
Medium Time Lag |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
1 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
500 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
3.5 A |
End Cap |
Nickel |
10 kA |
Bulk |
0.41 in (10.41 mm) |
CC |
500 V |
Midget |
0.41 x 1.5 in (10.41 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
20 A |
End Cap |
200 kA |
Box |
0.811 in (20.6 mm) |
J |
600 V |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
10 A |
Tab/Blade |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
100 A |
Tab/Blade |
905 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1 in (25.4 mm) |
500 V |
10 ms |
2.125 in (53.98 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.125 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
150 V |
6.25 A |
End Cap |
200 kA |
Rated Breaking Capacity at 150 VDC: 20000 A |
Box |
0.394 in (10 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.496 in (38 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
15 A |
End Cap |
100 kA |
0.394 in (10 mm) |
600 V |
0.394 x 1.378 in (10 x 35 mm) |
1.378 in (35 mm) |
CSA; UL |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
480 V |
300 V |
25 A |
End Cap |
100 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Box |
0.406 in (10.3 mm) |
G |
480 V |
0.406 x 1.62 in (10.3 x 41.15 mm) |
1.62 in (41.15 mm) |
CSA; UL |
Fast And Time Delay |
||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
10 A |
End Cap |
400 J |
-55 °C (-67 °F) |
Nickel |
1 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
400 |
Box |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
540 μJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
0.0005 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
56.43 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
20 ms |
56.43 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
42.795 J |
-55 °C (-67 °F) |
Nickel |
50 A |
10 ms |
42.795 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
50 mA |
End Cap |
490 μJ |
-55 °C (-67 °F) |
35 A |
3 ms |
Pre Arcing Time: Open within 3 ms at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
198.5 J |
-55 °C (-67 °F) |
Nickel |
63 A |
20 ms |
198.5 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
46 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
10 ms |
0.028 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
130 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
130 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
199 J |
-60 °C (-76 °F) |
Nickel |
100 A |
5 s |
199 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AG |
1.25 x 0.25 in (31.75 x 6.35 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
25 A |
End Cap |
16.5 kJ |
-55 °C (-67 °F) |
Nickel |
300 A |
4 h |
16500 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
25 A |
End Cap |
16.5 kJ |
-60 °C (-76 °F) |
Nickel |
300 A |
5 s |
16500 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
1.25 x 0.25 in (31.75 x 6.35 mm) |
1.25 in (31.75 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
80 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
5.6 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
10 A |
End Cap |
3.6 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
0.563 in (14.3 mm) |
Indicator |
0.563 x 2.008 in (14.3 x 51 mm) |
2.008 in (51 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
32 A |
End Cap |
55 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Conquer Electronics |
Electric Fuse |
Inline/Holder |
250 V |
300 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
Box |
0.181 in (4.6 mm) |
3 s |
0.181 x 0.571 in (4.6 x 14.5 mm) |
0.571 in (14.5 mm) |
CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
160 A |
Tab/Blade |
47.465 kJ |
20 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
110 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
75 V |
3.15 A |
End Cap |
17.72 J |
-55 °C (-67 °F) |
Nickel |
35 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1.5 A |
End Cap |
59.7 J |
-55 °C (-67 °F) |
Nickel |
100 A |
5 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
40.1 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
15 A |
End Cap |
245 J |
-55 °C (-67 °F) |
Nickel |
400 A |
5 s |
Rated Breaking Capacity at 125 VDC: 600 A |
245 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; TUV; UL |
125 °C (257 °F) |
Time Delay |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
30 A |
End Cap |
200 kA |
Bulk |
0.811 in (20.6 mm) |
2.252 in (57.2 mm) |
CE; CSA; QPL; UL |
Fast |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
80 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 x 0.563 in (22.28 x 14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
|||||||||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
500 V |
2 A |
End Cap |
80 A |
Bulk |
0.205 in (5.2 mm) |
500 V |
5 ms |
0.197 x 1.181 in (5 x 30 mm) |
1.181 in (30 mm) |
Very Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
17.52 J |
-55 °C (-67 °F) |
Nickel |
100 A |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.005 |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
400 V |
20 A |
End Cap |
200 kA |
0.827 in (21 mm) |
2.244 in (57 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
0.409 in (10.4 mm) |
0.409 x 1.5 in (10.4 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
250 V |
40 A |
Tab/Blade |
1.4 kJ |
Rated Breaking Capacity at 250 VDC: 1400 A |
Box |
0.827 in (21 mm) |
0.827 x 2.185 in (21 x 55.5 mm) |
2.185 in (55.5 mm) |
BS; IEC |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
2 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
100 A |
Box |
0.406 in (10.3 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
2.8 A |
End Cap |
100 A |
Box |
0.406 in (10.3 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
8 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.56 in (14.22 mm) |
RK5 |
250 V |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
3.15 A |
End Cap |
7.7 J |
50 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.252 in (6.4 mm) |
0.252 x 1.252 in (6.4 x 31.8 mm) |
1.252 in (31.8 mm) |
CE; CSA; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
300 V |
160 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 160 VDC: 20000 A |
Box |
0.406 in (10.3 mm) |
0.406 x 0.874 in (10.3 x 22.2 mm) |
0.874 in (22.2 mm) |
CE; CSA; UL |
Very Fast |
||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
98 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
2 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
100 mA |
End Cap |
2.6 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
3 ms |
0.0045 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.