Inline/Holder Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

T-3

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

3 A

10 kA

Box

CE; CSA; UL

Time Delay

TDC600-10A

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

Silver

200 A

0.248 in (6.3 mm)

e4

0.248 x 1 in (6.3 x 25.4 mm)

1 in (25.4 mm)

UL

Fast

V300697

Mersen S A

Electric Fuse

Inline/Holder

690 V

200 A

Tab/Blade

2.6 kJ

200 kA

Bulk

1.874 in (47.6 mm)

2.008 in (51 mm)

Indicator

2.224 in (56.5 mm)

CCC; CE; CSA; EAC; IEC; UL; VDE

Ultra Fast

0001.2505

Schurter Ag

Electric Fuse

Inline/Holder

250 V

300 V

1.25 A

End Cap

1.86 J

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 300 VDC: 1500 A

1.86

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0001.2716.11

Schurter Ag

Electric Fuse

Inline/Holder

250 V

125 V

16 A

End Cap

1.272 kJ

-55 °C (-67 °F)

Gold

500 A

Rated Breaking Capacity at 125 VDC: 1500 A

Bulk

0.205 in (5.2 mm)

e4

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

125 °C (257 °F)

Time Lag

0034.3120G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

16 J

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3120.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

16 J

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3122

Schurter Ag

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

47 J

-55 °C (-67 °F)

Nickel

35 A

Box

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3123G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

68.3 J

-55 °C (-67 °F)

Nickel

40 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.3123.G

Schurter Ag

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

68.3 J

-55 °C (-67 °F)

Nickel

40 A

Bulk

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

02130.25MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

555 mJ

-55 °C (-67 °F)

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

02130.63MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

4.8 J

-55 °C (-67 °F)

35 A

20 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

021302.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

138 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

138

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

021306.3MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

600 J

-55 °C (-67 °F)

Nickel

63 A

20 ms

600

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0217.500HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

215 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

0.215

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Very Fast

0218.100MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

79 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

0.079

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.250MXBP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

540.5 mJ

-55 °C (-67 °F)

Tin

35 A

0.5405

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.250TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

540.5 mJ

-55 °C (-67 °F)

Matte Tin

35 A

20 ms

0.5405

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE

125 °C (257 °F)

Time Lag

0218004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

69.1 J

-55 °C (-67 °F)

Nickel

40 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

69.1

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

021802.5HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

23.25 J

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0219.315MXAP

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

1.23 J

-55 °C (-67 °F)

Nickel

150 A

20 ms

1.23

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Time Lag

021906.3MXABP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

1.093 kJ

-55 °C (-67 °F)

150 A

Pre Arcing Time: Open within 0.02 s at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; CUL; IEC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

02193.15MXAP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

202 J

-55 °C (-67 °F)

Nickel

150 A

20 ms

202

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

022902.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.5 A

End Cap

50 J

-55 °C (-67 °F)

Tin

100 A

3 s

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.189 in (4.8 mm)

e3

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0233004.MXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

51.61 J

-55 °C (-67 °F)

Nickel

10 kA

600 ms

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Medium

0287003.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.752 x 0.201 x 0.484 in (19.1 x 5.1 x 12.3 mm)

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287003.L

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0287003.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

3 A

Tab/Blade

7.4 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

0297030.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

1.23 kJ

-40 °C (-40 °F)

Silver

1 kA

30 ms

1130

0.429 in (10.9 mm)

0.15 in (3.8 mm)

e4

32 V

Mini

0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

0298040.UXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.7 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298040.ZXB

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

8.7 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0313.400MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

1.35 J

-60 °C (-76 °F)

Nickel

35 A

5 s

1.35

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0313.600VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 mA

End Cap

4 J

-55 °C (-67 °F)

Nickel

35 A

313

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0313003.HXIDP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

-55 °C (-67 °F)

Nickel

100 A

Bulk

0.25 in (6.35 mm)

Indicator

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL; KTL; PSE

125 °C (257 °F)

Time Lag

0313003.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

200 J

-55 °C (-67 °F)

Nickel

100 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313004.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

76.1 J

-55 °C (-67 °F)

Nickel

200 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

76.1

Bulk

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

445 J

-55 °C (-67 °F)

Nickel

200 A

4 h

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

701 J

-60 °C (-76 °F)

Nickel

200 A

5 s

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

0313015.MXP

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

End Cap

2.65 kJ

-60 °C (-76 °F)

Nickel

300 A

5 s

1870

Bulk

0.25 in (6.35 mm)

Supplemental

32 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

UL

125 °C (257 °F)

Time Lag

031301.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.5 A

End Cap

38 J

-60 °C (-76 °F)

Nickel

100 A

5 s

38

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0314006.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

45 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

45

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0314010.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

206 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

206

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0314010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

206 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

206

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0326010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

137 J

-55 °C (-67 °F)

Nickel

400 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

137

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Delay

0326.010MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 mA

End Cap

130 μJ

-55 °C (-67 °F)

Nickel

100 A

5 s

0.0014

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

125 °C (257 °F)

Time Delay

0477010.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

10 A

End Cap

509 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; PSE; TUV; UL

125 °C (257 °F)

Time Lag

0481.500HXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

500 mA

End Cap

490 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0498040.M

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

10 kJ

-40 °C (-40 °F)

Tin

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

e3

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.