250 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

C310T-2-R-TR1

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

27.2 J

Tin/Copper

35 A

27.2

Tape And Reel

0.157 in (4 mm)

e2

250 V

0.157 x 0.453 in (4 x 11.5 mm)

0.453 in (11.5 mm)

CQC; IEC; KTL; UL; VDE

Time Delay

FLNR020.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

FNA-1/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

100 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNA-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

35 A

FNA

Box

0.817 in (20.75 mm)

Indicator

0.817 x 1.5 in (20.75 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNA-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNA-1/8

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

35 A

0.406 in (10.31 mm)

250 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

Time Lag

FNM-2-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2.25 A

End Cap

100 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

G4A01104C

Therm-o-disc

Thermal Fuse

Through Hole Mount

250 V

10 A

Pin Wire

Tape And Reel, 14 inch

0.157 in (4 mm)

250 V

0.579 in (14.7 mm)

G4A01152C

Therm-o-disc

Thermal Fuse

Through Hole Mount

250 V

10 A

Pin Wire

Tape And Reel, 14 inch

0.157 in (4 mm)

250 V

0.579 in (14.7 mm)

GDB-3.15A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

13 J

35 A

0.205 in (5.2 mm)

250 V

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

UL; VDE

Fast

MDL-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

11.498 J

Nickel

35 A

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

OT450

Mersen S A

Electric Fuse

Inline/Holder

250 V

250 V

450 A

Tab/Blade

50 kA

Rated Breaking Capacity at 250 VDC: 20000 A

2.598 in (66 mm)

2.598 x 5.906 in (66 x 150 mm)

5.906 in (150 mm)

CSA; UL

TR1R

Mersen S A

Electric Fuse

Inline/Holder

250 V

250 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CSA; UL

Time Delay

TR2/C515-125-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

125 mA

Pin Wire

101 mJ

-55 °C (-67 °F)

Tin

35 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515-1.25-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

1.25 A

Pin Wire

22.961 J

-55 °C (-67 °F)

Tin

100 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

TR2/C515S-3-R

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

3 A

Pin Wire

80.426 J

-55 °C (-67 °F)

Tin

100 A

3 s

Pre Arcing Time: Open within 3 s at 200% Rated Current

Tape And Reel

0.217 in (5.5 mm)

e3

250 V

3 s

0.197 x 0.591 in (5 x 15 mm)

0.217 x 0.598 in (5.5 x 15.2 mm)

0.598 in (15.2 mm)

CSA, UL

85 °C (185 °F)

Time Delay

0001.1012

Schurter Ag

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

36.7 J

-55 °C (-67 °F)

Nickel

1.5 kA

Box

0.787 in (20 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.205 in (5.2 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Very Fast

0034.1521.PT

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

3.15 A

Pin Wire

16.1 J

-55 °C (-67 °F)

Tin

35 A

Bulk

0.213 in (5.4 mm)

L

e3

250 V

10 ms

0.213 x 0.886 in (5.4 x 22.5 mm)

0.213 x 0.886 in (5.4 x 22.5 mm)

0.886 in (22.5 mm)

UL

125 °C (257 °F)

Very Fast

0034.3120

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

16 J

-55 °C (-67 °F)

Nickel

35 A

Box

0.205 in (5.2 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.5613.11

Schurter Ag

Electric Fuse

Inline/Holder

250 V

400 mA

End Cap

768 mJ

-55 °C (-67 °F)

Gold

35 A

Bulk

0.205 in (5.2 mm)

e4

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC, CUL, UL, VDE

125 °C (257 °F)

Time Lag

0034.5716.11

Schurter Ag

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

124 J

-55 °C (-67 °F)

Gold

35 A

Bulk

0.205 in (5.2 mm)

e4

150 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

125 °C (257 °F)

Super Time Lag

0213001.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

19.2 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

19.2

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEV; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0217.050MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

490 μJ

-55 °C (-67 °F)

Nickel

35 A

3 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

0217.250MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

40 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

02170.08HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

80 mA

End Cap

1.32 mJ

-55 °C (-67 °F)

35 A

3 ms

Pre Arcing Time: Open within 3 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

02170.08MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

80 mA

End Cap

1.32 mJ

-55 °C (-67 °F)

35 A

3 ms

Pre Arcing Time: Open within 3 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0217008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

198.16 J

-55 °C (-67 °F)

Nickel

80 A

10 ms

198.16

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; KC; PSE; VDE; UL

125 °C (257 °F)

Very Fast

0217008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

198.16 J

-55 °C (-67 °F)

Nickel

80 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; KC; PSE; VDE; UL

125 °C (257 °F)

Very Fast

0217015.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

607.135 J

-55 °C (-67 °F)

Nickel

150 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; PSE; VDE

125 °C (257 °F)

Very Fast

0218001.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

6.73 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

6.73

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

021801.6TXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

1.6 A

End Cap

23.35 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

23.35

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

022503.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

3.5 A

End Cap

6.7 J

-55 °C (-67 °F)

Tin

100 A

1 s

Rated Breaking Capacity at 125 VDC: 10000 A

6.7

Bulk

0.189 in (4.8 mm)

e3

250 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

02302.25MXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

125 V

2.25 A

Pin Wire

39 J

-55 °C (-67 °F)

Matte Tin

100 A

3 s

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.189 in (4.8 mm)

e3

2AG

0.185 x 0.57 in (4.7 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0239.500HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.985 J

-55 °C (-67 °F)

Nickel

35 A

4 h

1.985

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; UL

125 °C (257 °F)

Time Lag

0239.500MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

1.985 J

-55 °C (-67 °F)

Tin

35 A

2 m

1.985

Bulk

0.205 in (5.2 mm)

Supplemental

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; UL

125 °C (257 °F)

Time Lag

0263005.WRT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Pin Wire

5.55 J

-55 °C (-67 °F)

Tin

50 A

100 ms

Tape And Reel

0.155 in (3.94 mm)

e3

250 V

Pico

0.155 x 0.28 in (3.94 x 7.11 mm)

CSA, PSE, UL

125 °C (257 °F)

Very Fast

0263005WRT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Pin Wire

5.55 J

-55 °C (-67 °F)

Tin

50 A

Tape And Reel

0.145 in (3.68 mm)

e3

0.145 x 0.3 in (3.68 x 7.62 mm)

0.3 in (7.62 mm)

CSA; UL

125 °C (257 °F)

Very Fast

026301.5HAT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.5 A

Pin Wire

295.8 mJ

-55 °C (-67 °F)

Pure Tin

50 A

100 ms

Ammo Pack

0.155 in (3.94 mm)

250 V

Pico

0.155 x 0.28 in (3.94 x 7.11 mm)

CSA, PSE, UL

125 °C (257 °F)

Very Fast

026301.5MXL

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.5 A

Pin Wire

295.8 mJ

-55 °C (-67 °F)

50 A

100 ms

Bulk

0.155 in (3.94 mm)

250 V

Pico

CSA, PSE, UL

125 °C (257 °F)

Very Fast

026301.5WAT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.5 A

Pin Wire

295.8 mJ

-55 °C (-67 °F)

Pure Tin

50 A

100 ms

Ammo Pack

0.155 in (3.94 mm)

250 V

Pico

0.155 x 0.28 in (3.94 x 7.11 mm)

CSA, PSE, UL

125 °C (257 °F)

Very Fast

026301.5WRT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.5 A

Pin Wire

295.8 mJ

-55 °C (-67 °F)

Tin

50 A

100 ms

Tape And Reel

0.155 in (3.94 mm)

e3

250 V

Pico

0.155 x 0.28 in (3.94 x 7.11 mm)

CSA, PSE, UL

125 °C (257 °F)

Very Fast

0313.250MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 mA

End Cap

385 mJ

-60 °C (-76 °F)

Nickel

35 A

5 s

0.385

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

0318.500HXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

500 mA

Pin Wire

483 mJ

-55 °C (-67 °F)

Tin

35 A

5 s

0.483

Tape And Reel

0.275 in (6.99 mm)

e3

250 V

3AG

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

0691-0160-02

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

160 mA

Pin Wire

16 mJ

-55 °C (-67 °F)

Matte Tin

50 A

Ammo Pack

0.329 in (8.35 mm)

e3

250 V

20 ms

Micro

0.329 x 0.303 in (8.35 x 7.7 mm)

0.303 in (7.7 mm)

CSA; CUL; SEMKO; UL; VDE

125 °C (257 °F)

Fast

0FLM020.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

20 A

End Cap

10 kA

Pre Arcing Time: Open within 12 s at 200% Rated Current

0.406 in (10.31 mm)

250 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

0FLM020T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

20 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

2302.25P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.25 A

Pin Wire

39 J

-55 °C (-67 °F)

Tin

100 A

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; METI; PSE; UL

125 °C (257 °F)

Slow

26301.5

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.5 A

Pin Wire

398 mJ

-55 °C (-67 °F)

Tin/Lead

50 A

100 ms

Pre Arcing Time: Open within 0.1 s at 300% Rated Current

0.145 in (3.68 mm)

e0

250 V

0.145 x 0.3 in (3.68 x 7.62 mm)

0.3 in (7.62 mm)

CSA; UL

125 °C (257 °F)

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.