250 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

3403.0155.24

Schurter Ag

Electric Fuse

Surface Mount

250 V

250 V

80 mA

Wraparound

22 mJ

-55 °C (-67 °F)

Tin

200 A

Tape And Reel, 13 inch

0.398 in (10.1 mm)

0.118 in (3 mm)

e3

10 ms

0.118 x 0.398 in (3 x 10.1 mm)

0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm)

0.118 in (3 mm)

CUL; CQC; KTL; UL; VDE

125 °C (257 °F)

Time Lag

NON-6

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

50 kA

Rated Breaking Capacity at 125 VDC: 50000 A

Box

0.56 in (14.22 mm)

K5

250 V

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

021806.3HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

198.5 J

-55 °C (-67 °F)

Nickel

63 A

198.5

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0218.063HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

28 mJ

-55 °C (-67 °F)

Nickel

35 A

0.028

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

3403.0169.24

Schurter Ag

Electric Fuse

Surface Mount

250 V

125 V

2 A

Wraparound

7.3 J

-55 °C (-67 °F)

Tin

200 A

Tape And Reel, 13 inch

0.398 in (10.1 mm)

0.118 in (3 mm)

e3

10 ms

0.118 x 0.398 in (3 x 10.1 mm)

0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm)

0.118 in (3 mm)

CUL; CQC; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

02153.15HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

43.255 J

-55 °C (-67 °F)

Tin

1.5 kA

10 ms

43.25

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0215.315HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

315 mA

End Cap

975 mJ

-55 °C (-67 °F)

Tin

1.5 kA

5 ms

0.975

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CUL; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0216004.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

14.995 J

-55 °C (-67 °F)

Nickel

1.5 kA

20 ms

14.995

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Fast

0216004MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

4 A

End Cap

14.995 J

-55 °C (-67 °F)

Tin

1.5 kA

10 ms

Bulk

0.205 in (5.2 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC, CE, CSA, PSE, UL, VDE

125 °C (257 °F)

Fast

0318002.HXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

5.2 J

-55 °C (-67 °F)

Matte Tin

100 A

5 s

Bulk

0.275 in (6.99 mm)

e3

3AG

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

213.5

Littelfuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

2.9 J

-55 °C (-67 °F)

Tin

100 A

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL

125 °C (257 °F)

Time Lag

ABC-10-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

208.8 J

Nickel

200 A

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

NON-15

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

15 A

End Cap

50 kA

Rated Breaking Capacity at 125 VDC: 50000 A

Box

0.56 in (14.22 mm)

K5

250 V

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; UL

0218010.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

568 J

-55 °C (-67 °F)

Nickel

100 A

20 ms

Pre Arcing Time: Open within 20 ms at 1000% Rated Current

568

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0234010.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

10 A

End Cap

51.4 J

-55 °C (-67 °F)

Nickel

200 A

400 ms

129.02

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

172200.8

Siba

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

230 J

1.5 kA

Bulk

0.205 in (5.2 mm)

250 V

5 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

DIN 41571-2

Medium Time Lag

BK/MDA-10-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

10 A

End Cap

1.62 kJ

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

BK/MDA-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

5 A

End Cap

380.49 J

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

BK1/MDA-5-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

345.9 J

Nickel

200 A

380.49

Box

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

FNM-5

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

200 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

MCMET160MA250V

Spc Technology/ Multicomp

Electric Fuse

Through Hole Mount

250 V

160 mA

Pin Wire

133.1 mJ

-55 °C (-67 °F)

35 A

0.329 in (8.35 mm)

3 ms

0.329 x 0.303 in (8.35 x 7.7 mm)

0.303 in (7.7 mm)

125 °C (257 °F)

Slow

0235003.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

8.395 J

-55 °C (-67 °F)

Nickel

100 A

5 s

8.4

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 x 0.205 in (20 x 5.2 mm)

0.787 in (20 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

0312005.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

50 J

-55 °C (-67 °F)

Nickel

200 A

5 s

50

Bulk

0.25 in (6.35 mm)

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0315003.MXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3 A

Pin Wire

200 J

-60 °C (-76 °F)

100 A

5 s

Bulk

0.275 in (6.99 mm)

3AG

0.275 x 1.274 in (6.99 x 32.36 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

179020.1

Siba

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

1.5 J

35 A

Bulk

0.205 in (5.2 mm)

250 V

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

BEAB, SEMKO, UL, VDE

Very Fast

SS-5H-2A-AP

Eaton Corporation

Electric Fuse

Through Hole Mount

250 V

2 A

Pin Wire

29.8 J

-40 °C (-40 °F)

100 A

Ammo Pack

0.335 in (8.5 mm)

0.169 in (4.3 mm)

20 ms

0.335 x 0.169 x 0.329 in (8.5 x 4.3 x 8.35 mm)

0.309 in (7.85 mm)

CCC; CUL; KC; PSE; TUV; UL; VDE

125 °C (257 °F)

Time Delay

0234004.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

10.37 J

-55 °C (-67 °F)

Nickel

200 A

400 ms

10.37

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0239002.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

50.585 J

-55 °C (-67 °F)

Nickel

100 A

4 h

50.585

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

BK/AGC-1-R

Cooper Industries

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

1.615 J

Nickel

35 A

1.615

Box

0.25 in (6.35 mm)

250 V

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK-AGC-1-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

3.24 J

-55 °C (-67 °F)

Nickel

35 A

Pre Arcing Time: Open within 120 s at 200% Rated Current

1.615

Box

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

125 °C (257 °F)

Fast

SDL.200

Conquer Electronics

Electric Fuse

Inline/Holder

250 V

200 mA

End Cap

80 mJ

-55 °C (-67 °F)

35 A

Box

0.181 in (4.6 mm)

3 s

0.181 x 0.571 in (4.6 x 14.5 mm)

0.571 in (14.5 mm)

CSA; UL

125 °C (257 °F)

Time Lag

0001.1004

Schurter Ag

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

750 mJ

-55 °C (-67 °F)

Nickel

1.5 kA

Box

0.787 in (20 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.205 in (5.2 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Very Fast

0001.1009

Schurter Ag

Electric Fuse

Inline/Holder

250 V

3.15 A

End Cap

6.78 J

-55 °C (-67 °F)

Nickel

1.5 kA

Box

0.787 in (20 mm)

20 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.205 in (5.2 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Very Fast

0001.2511

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

5 A

End Cap

97.5 J

-55 °C (-67 °F)

Nickel

1.5 kA

Rated Breaking Capacity at 150 VDC: 1500 A

97.5

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; KTL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0218.630MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

630 mA

End Cap

4.675 J

-55 °C (-67 °F)

Nickel

35 A

20 ms

4.675

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0234002.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

9.97 J

-55 °C (-67 °F)

Tin

100 A

400 ms

9.97

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0314003.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

3 A

End Cap

14.6 J

-55 °C (-67 °F)

Nickel

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

14.6

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Fast

0697-0100-01

Bel Fuse

Electric Fuse

Through Hole Mount

250 V

100 mA

Pin Wire

20 mJ

-55 °C (-67 °F)

Matte Tin

35 A

Bulk

0.329 in (8.35 mm)

0.157 in (4 mm)

e3

250 V

20 ms

Micro

0.329 x 0.157 x 0.303 in (8.35 x 4 x 7.7 mm)

0.303 in (7.7 mm)

CCC; CUL; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0001.2514

Schurter Ag

Electric Fuse

Inline/Holder

250 V

150 V

10 A

End Cap

400 J

-55 °C (-67 °F)

Nickel

1 kA

Rated Breaking Capacity at 150 VDC: 1500 A

400

Box

0.205 in (5.2 mm)

10 ms

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CUL; METI; UL; VDE

125 °C (257 °F)

Time Lag

0034.6020

Schurter Ag

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

7.9 J

-40 °C (-40 °F)

Tin

35 A

Bulk

0.335 in (8.5 mm)

e3

3 ms

0.335 x 0.335 in (8.5 x 8.5 mm)

0.335 in (8.5 mm)

CUL; UL

85 °C (185 °F)

Very Fast

0216.063MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

540 μJ

-55 °C (-67 °F)

Nickel

1.5 kA

20 ms

0.0005

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

021606.3MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

56.43 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

20 ms

56.43

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Fast

0217005.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

42.795 J

-55 °C (-67 °F)

Nickel

50 A

10 ms

42.795

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Very Fast

02170.05HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

490 μJ

-55 °C (-67 °F)

35 A

3 ms

Pre Arcing Time: Open within 3 ms at 400% Rated Current

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 °C (257 °F)

Fast

021806.3MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6.3 A

End Cap

198.5 J

-55 °C (-67 °F)

Nickel

63 A

20 ms

198.5

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0218.063MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

46 mJ

-55 °C (-67 °F)

Nickel

35 A

10 ms

0.028

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; KC; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

031302.5HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

130 J

-55 °C (-67 °F)

Nickel

100 A

4 h

130

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

031302.5MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.5 A

End Cap

199 J

-60 °C (-76 °F)

Nickel

100 A

5 s

199

Bulk

0.25 in (6.35 mm)

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.