Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
250 V |
80 mA |
Wraparound |
22 mJ |
-55 °C (-67 °F) |
Tin |
200 A |
Tape And Reel, 13 inch |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
10 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; CQC; KTL; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
6 A |
End Cap |
50 kA |
Rated Breaking Capacity at 125 VDC: 50000 A |
Box |
0.56 in (14.22 mm) |
K5 |
250 V |
0.56 x 2 in (14.22 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
198.5 J |
-55 °C (-67 °F) |
Nickel |
63 A |
198.5 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
28 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
0.028 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
2 A |
Wraparound |
7.3 J |
-55 °C (-67 °F) |
Tin |
200 A |
Tape And Reel, 13 inch |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
10 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; CQC; KTL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
43.255 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
43.25 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
315 mA |
End Cap |
975 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
5 ms |
0.975 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CUL; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
14.995 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
14.995 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
4 A |
End Cap |
14.995 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Pin Wire |
5.2 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
5 s |
Bulk |
0.275 in (6.99 mm) |
e3 |
3AG |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
2.9 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
10 A |
End Cap |
208.8 J |
Nickel |
200 A |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
15 A |
End Cap |
50 kA |
Rated Breaking Capacity at 125 VDC: 50000 A |
Box |
0.56 in (14.22 mm) |
K5 |
250 V |
0.56 x 2 in (14.22 x 50.8 mm) |
2 in (50.8 mm) |
CE; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
568 J |
-55 °C (-67 °F) |
Nickel |
100 A |
20 ms |
Pre Arcing Time: Open within 20 ms at 1000% Rated Current |
568 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
51.4 J |
-55 °C (-67 °F) |
Nickel |
200 A |
400 ms |
129.02 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Medium |
||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
230 J |
1.5 kA |
Bulk |
0.205 in (5.2 mm) |
250 V |
5 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
DIN 41571-2 |
Medium Time Lag |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
10 A |
End Cap |
1.62 kJ |
Nickel |
200 A |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
380.49 J |
Nickel |
200 A |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
345.9 J |
Nickel |
200 A |
380.49 |
Box |
0.25 in (6.35 mm) |
250 V |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Time Delay |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
200 A |
Box |
0.406 in (10.3 mm) |
250 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
Spc Technology/ Multicomp |
Electric Fuse |
Through Hole Mount |
250 V |
160 mA |
Pin Wire |
133.1 mJ |
-55 °C (-67 °F) |
35 A |
0.329 in (8.35 mm) |
3 ms |
0.329 x 0.303 in (8.35 x 7.7 mm) |
0.303 in (7.7 mm) |
125 °C (257 °F) |
Slow |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
3 A |
End Cap |
8.395 J |
-55 °C (-67 °F) |
Nickel |
100 A |
5 s |
8.4 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 x 0.205 in (20 x 5.2 mm) |
0.787 in (20 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
50 J |
-55 °C (-67 °F) |
Nickel |
200 A |
5 s |
50 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
3 A |
Pin Wire |
200 J |
-60 °C (-76 °F) |
100 A |
5 s |
Bulk |
0.275 in (6.99 mm) |
3AG |
0.275 x 1.274 in (6.99 x 32.36 mm) |
1.288 in (32.72 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Siba |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
1.5 J |
35 A |
Bulk |
0.205 in (5.2 mm) |
250 V |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
BEAB, SEMKO, UL, VDE |
Very Fast |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Pin Wire |
29.8 J |
-40 °C (-40 °F) |
100 A |
Ammo Pack |
0.335 in (8.5 mm) |
0.169 in (4.3 mm) |
20 ms |
0.335 x 0.169 x 0.329 in (8.5 x 4.3 x 8.35 mm) |
0.309 in (7.85 mm) |
CCC; CUL; KC; PSE; TUV; UL; VDE |
125 °C (257 °F) |
Time Delay |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
10.37 J |
-55 °C (-67 °F) |
Nickel |
200 A |
400 ms |
10.37 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Medium |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
50.585 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
50.585 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
1.615 J |
Nickel |
35 A |
1.615 |
Box |
0.25 in (6.35 mm) |
250 V |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
3.24 J |
-55 °C (-67 °F) |
Nickel |
35 A |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
1.615 |
Box |
0.25 in (6.35 mm) |
250 V |
0.248 x 1.26 in (6.3 x 32 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Conquer Electronics |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
80 mJ |
-55 °C (-67 °F) |
35 A |
Box |
0.181 in (4.6 mm) |
3 s |
0.181 x 0.571 in (4.6 x 14.5 mm) |
0.571 in (14.5 mm) |
CSA; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
750 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
3.15 A |
End Cap |
6.78 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Box |
0.787 in (20 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.205 in (5.2 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
5 A |
End Cap |
97.5 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
97.5 |
Box |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; KTL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
630 mA |
End Cap |
4.675 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
4.675 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2 A |
End Cap |
9.97 J |
-55 °C (-67 °F) |
Tin |
100 A |
400 ms |
9.97 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Medium |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
3 A |
End Cap |
14.6 J |
-55 °C (-67 °F) |
Nickel |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
14.6 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
250 V |
100 mA |
Pin Wire |
20 mJ |
-55 °C (-67 °F) |
Matte Tin |
35 A |
Bulk |
0.329 in (8.35 mm) |
0.157 in (4 mm) |
e3 |
250 V |
20 ms |
Micro |
0.329 x 0.157 x 0.303 in (8.35 x 4 x 7.7 mm) |
0.303 in (7.7 mm) |
CCC; CUL; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Schurter Ag |
Electric Fuse |
Inline/Holder |
250 V |
150 V |
10 A |
End Cap |
400 J |
-55 °C (-67 °F) |
Nickel |
1 kA |
Rated Breaking Capacity at 150 VDC: 1500 A |
400 |
Box |
0.205 in (5.2 mm) |
10 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CUL; METI; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Schurter Ag |
Electric Fuse |
Through Hole Mount |
250 V |
4 A |
Pin Wire |
7.9 J |
-40 °C (-40 °F) |
Tin |
35 A |
Bulk |
0.335 in (8.5 mm) |
e3 |
3 ms |
0.335 x 0.335 in (8.5 x 8.5 mm) |
0.335 in (8.5 mm) |
CUL; UL |
85 °C (185 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
540 μJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
0.0005 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
56.43 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
20 ms |
56.43 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
5 A |
End Cap |
42.795 J |
-55 °C (-67 °F) |
Nickel |
50 A |
10 ms |
42.795 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
50 mA |
End Cap |
490 μJ |
-55 °C (-67 °F) |
35 A |
3 ms |
Pre Arcing Time: Open within 3 ms at 400% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
198.5 J |
-55 °C (-67 °F) |
Nickel |
63 A |
20 ms |
198.5 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
46 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
10 ms |
0.028 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
130 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
130 |
Bulk |
0.25 in (6.35 mm) |
Supplemental |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
2.5 A |
End Cap |
199 J |
-60 °C (-76 °F) |
Nickel |
100 A |
5 s |
199 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AG |
1.25 x 0.25 in (31.75 x 6.35 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.