600 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LFCL500C1

Littelfuse

Electric Fuse

Inline/Holder

600 V

Pin Wire

200 kA

JTD01.6ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLKD006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLDR002.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLSR015.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

2CO015

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

15 A

Tab/Blade

200 kA

2CO

Rated Breaking Capacity at 250 VDC: 80000 A

0.827 in (21 mm)

0.827 x 2.205 in (21 x 56 mm)

2.205 in (56 mm)

CSA

JTD045ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

45 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.063 in (27 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.374 in (60.3 mm)

CSA; UL

Time Delay

CCMR004.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

1.87 kJ

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR04.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

4.5 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 250 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR.500T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

CCMR045

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

45 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.85 in (21.6 mm)

0.85 x 1.882 in (21.6 x 47.8 mm)

1.882 in (47.8 mm)

CE; CSA; UL

Time Delay

LDC0750

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

LLSRK045

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

45 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.063 in (27 mm)

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CSA; UL

Time Delay

0JLS070.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

70 A

Tab/Blade

200 kA

1 in (25.4 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; QPL; UL

Fast

SPFJ300

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

300 A

Tab/Blade

143 kJ

200 kA

12 m

Rated Breaking Capacity at 1000 VDC: 20000 A

2 in (50.8 mm)

Midget

2 x 3.374 in (50.8 x 85.7 mm)

3.374 in (85.7 mm)

CE; IEC; UL; VDE

IDSR007

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

7 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JLLS006

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

CCMR008.HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

431 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR035.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

0.85 in (21.6 mm)

600 V

1.882 in (47.8 mm)

CE; CSA; UL

Time Delay

07945810193

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

300 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

101 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

KLSR080

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CSA; UL

Fast

KLDR005

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

63.33 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

IDSR1.40

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.4 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC; 20000

Indicator

CSA; MSHA; UL

Time Delay

RLS110

Littelfuse

Electric Fuse

Inline/Holder

600 V

110 A

Tab/Blade

10 kA

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

KLKD.125H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

125 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

FLSR080.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

FLSR.800ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

KLKD012.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

End Cap

440 J

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

LDC1600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.6 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

IDSR009.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

150 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLLU3000.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

5 in (127 mm)

4 in (101.6 mm)

CE; CSA; UL

Time Delay

KLDR2.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

JTD03.5ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

NLS225

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

50 kA

Rated Breaking Capacity at 500 VDC; 50000

2.594 in (65.9 mm)

2.594 x 7.878 in (65.9 x 200.1 mm)

7.878 in (200.1 mm)

CSA; UL

RLS175

Littelfuse

Electric Fuse

Inline/Holder

600 V

175 A

Tab/Blade

10 kA

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CE; CSA; UL

JTD28/10ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

IDSR6.25T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6.25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

JLLS250

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.594 in (40.5 mm)

1.594 x 1.72 in (40.5 x 43.7 mm)

1.72 in (43.7 mm)

CSA; UL

Fast

NLS006

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

50 kA

Rated Breaking Capacity at 600 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

KLKD5-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

Tab/Blade

34.163 J

-55 °C (-67 °F)

100 kA

347 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

607 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

07945810215

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

9 A

End Cap

164.221 J

-55 °C (-67 °F)

100 kA

587 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

992 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

KLPC0600

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

0JTD01.6TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

0JTD1.25TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

0JTD080.VXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.126 in (28.6 mm)

Indicator

2.626 in (66.7 mm)

CSA; UL

Time Delay

0JTD110.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Indicator

3 in (76.2 mm)

CSA; UL

Time Delay

0JTD500.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

Indicator

3.752 in (95.3 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.