600 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

L60S2

Littelfuse

Electric Fuse

Inline/Holder

600 V

2 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Fast

CCMR.200T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

200 mA

End Cap

200 kA

CCMR

Rated Breaking Capacity at 250 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR03.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.5 A

End Cap

21.42 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0LDC750.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

750 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, UL

Fast

LFCL750A1

Littelfuse

Electric Fuse

Inline/Holder

600 V

Pin Wire

200 kA

NLS100

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

100 A

Tab/Blade

158 kJ

50 kA

1.311 in (33.3 mm)

1.311 x 5.874 in (33.3 x 149.2 mm)

7.874 in (200 mm)

CE; CSA; UL

KLDR07.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7.5 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

RLS225

Littelfuse

Electric Fuse

Inline/Holder

600 V

225 A

Tab/Blade

10 kA

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CE; CSA; UL

KLPC1100

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

1.1 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

KLC350

Littelfuse

Electric Fuse

Inline/Holder

600 V

350 A

Tab/Blade

-55 °C (-67 °F)

200 kA

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

IDSR025.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

2CM100

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

100 A

Tab/Blade

200 kA

2CM

Rated Breaking Capacity at 250 VDC: 80000 A

1.22 in (31 mm)

1.22 x 2.598 in (31 x 66 mm)

2.598 in (66 mm)

CSA

KLDR006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLC500

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 A

Tab/Blade

-55 °C (-67 °F)

200 kA

2.5 in (63.5 mm)

2.5 x 2.843 in (63.5 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

KLKD.200T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

200 mA

End Cap

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

KLDR02.8TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

21.28 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

JTD01.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLPC1000

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

1 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

IDSR04.5ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

4.5 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

FLSR350.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

IDSR030

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

0.752 x 5 in (19.1 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

0KLK03.5T

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

3.5 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

CCMR03.2TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3.2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

CCMR006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

6 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 250 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLDR04.5HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

83.89 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLK3.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

3.5 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

KLK025

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

25 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 50000 A

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

FLSR010

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

10 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLC8

Littelfuse

Electric Fuse

Inline/Holder

600 V

8 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLKD002R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2 A

End Cap

12 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

L60S12

Littelfuse

Electric Fuse

Inline/Holder

600 V

12 A

End Cap

200 kA

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Fast

CCMR070

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

7 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 250 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

2CO030

Littelfuse

Electric Fuse

Inline/Holder

600 V

250 V

30 A

Tab/Blade

200 kA

2CO

Rated Breaking Capacity at 250 VDC: 80000 A

0.827 in (21 mm)

0.827 x 2.205 in (21 x 56 mm)

2.205 in (56 mm)

CSA

FLSR.400

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

400 mA

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD6

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

62.951 J

-55 °C (-67 °F)

100 kA

423 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

735 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

JLLS025.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

FLSR01.4ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

JLLS225.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.594 in (40.5 mm)

600 V

1.713 in (43.5 mm)

CE; CSA; UL

Fast

JTD05.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

JLLS1100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.1 kA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.63 in (66.8 mm)

2.63 x 2.299 in (66.8 x 58.4 mm)

2.299 in (58.4 mm)

UL

Fast

SLC008

Littelfuse

Electric Fuse

Inline/Holder

600 V

8 A

End Cap

100 kA

0.406 in (10.3 mm)

0.406 x 1.311 in (10.3 x 33.3 mm)

1.311 in (33.3 mm)

CSA; UL

Medium Time Delay

LLSRK020ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD25

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

834.529 J

-55 °C (-67 °F)

100 kA

1.007 ms

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

2.085 ms

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, IEC, UL, VDE

125 °C (257 °F)

Fast

LFCL500C6

Littelfuse

Electric Fuse

Inline/Holder

600 V

Pin Wire

200 kA

FLSR070ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; QPL; UL

Time Delay

KLKD012.H

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

12 A

End Cap

440 J

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

KLDR.125HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 mA

End Cap

700 μJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0477001.MX6EP

Littelfuse

Electric Fuse

Through Hole Mount

600 V

400 V

1 A

Pin Wire

1.8 J

-55 °C (-67 °F)

Tin

100 A

Rated Breaking Capacity at 400 VDC: 1500 A

Bulk

0.228 in (5.8 mm)

e3

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

PSE; UL; VDE

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.