600 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LVSP0010TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

1.3 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

0LDC1100.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.1 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

LLSRK01.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JTD56/10ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

5.6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

IDSR150

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.787 in (45.4 mm)

1.752 x 9.626 in (44.5 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

LLSRK075ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

75 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

KLSR110

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

110 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

9.626 in (244.5 mm)

CSA; UL

Fast

KLKD3-R

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

3 A

Tab/Blade

7.821 J

-55 °C (-67 °F)

100 kA

211 µs

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

449 µs

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.53 in (10.31 x 38.86 mm)

1.5 in (38.1 mm)

CE; IEC; UL

125 °C (257 °F)

Fast

LDC1601

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.601 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

JLLS001.TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

600 V

1.5 in (38.1 mm)

CE; CSA; UL

Fast

KLKR.125T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 mA

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Fast

KLLU3000

Littelfuse

Electric Fuse

Inline/Holder

600 V

3 kA

Tab/Blade

200 kA

5 in (127 mm)

L

600 V

5 x 4 in (127 x 101.6 mm)

4 in (101.6 mm)

CSA; UL

Time Delay

JTD01.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

KLDR.750T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

750 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

KLQ005

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

End Cap

Nickel

10 kA

0.406 in (10.31 mm)

600 V

Midget

0.406 x 1.375 in (10.31 x 34.93 mm)

1.375 in (34.93 mm)

CSA; UL

Time Delay

JLLS001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

FLSR250ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

IDSR175ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

175 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

KLDR002

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

861.5 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

KLK25

Littelfuse

Electric Fuse

Inline/Holder

600 V

25 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

KLDR6.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.25 A

End Cap

147.6 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

IDSR080

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

80 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

1.283 in (32.6 mm)

31.8mm x 200mm

7.874 in (200 mm)

CSA; UL

Time Delay

NLS010

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

10 A

End Cap

50 kA

Rated Breaking Capacity at 500 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

07945810194

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

500 mA

End Cap

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 600 VDC: 50000 A

Bulk

0.406 in (10.31 mm)

141 µs

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Fast

JTD110

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

3 in (76.2 mm)

CSA; UL

Time Delay

JLLS100.V

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.827 in (21 mm)

600 V

1.626 in (41.3 mm)

CE; CSA; UL

Fast

LLSRK350ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; UL

Time Delay

KLLU1000

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 kA

Tab/Blade

200 kA

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

L60S090

Littelfuse

Electric Fuse

Inline/Holder

600 V

90 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1.063 in (27 mm)

2.906 in (73.8 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LDC700

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

700 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CSA; UL

Fast

JLLS035.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

35 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.992 in (25.2 mm)

600 V

1.563 in (39.7 mm)

CE; CSA; UL

Fast

FLSR125ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

Indicator

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; QPL; UL

Time Delay

10E4PT.6

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

37.5 kA

0.813 in (20.64 mm)

0.813 x 4.6 in (20.64 x 116.84 mm)

4.6 in (116.84 mm)

Medium

0JTD003.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

820 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

600 V

2.252 in (57.2 mm)

CSA; UL

Time Delay

LFCL500C3

Littelfuse

Electric Fuse

Inline/Holder

600 V

Pin Wire And Tab/Blade

200 kA

JLLS100

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.642 in (20.6 x 41.7 mm)

1.642 in (41.7 mm)

CSA; UL

Fast

LLSRK1.25ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLKD005.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

5 A

End Cap

100 kA

KLKD

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

CCMR009

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

9 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR1.13

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1.125 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

CSA; UL

Time Delay

KLC070

Littelfuse

Electric Fuse

Inline/Holder

600 V

70 A

Tab/Blade

-55 °C (-67 °F)

200 kA

1 in (25.4 mm)

2.874 in (73 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L60S050

Littelfuse

Electric Fuse

Inline/Holder

600 V

50 A

Tab/Blade

-55 °C (-67 °F)

200 kA

0.811 in (20.6 mm)

2.78 in (70.6 mm)

CSA; UL

125 °C (257 °F)

Very Fast

FLSR2.25

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

5 in (127 mm)

CSA; UL

Time Delay

LLSRK125

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.843 in (46.8 mm)

1.843 x 9.626 in (46.8 x 244.5 mm)

9.626 in (244.5 mm)

CSA; UL

Time Delay

KLDR001

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

449.4 mJ

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

0JLS006.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

6 A

End Cap

200 kA

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; QPL; UL

Fast

LLSRK.800

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LDC1300

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

1.3 kA

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

3 in (76.2 mm)

3 x 3.752 in (76.2 x 95.3 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.