Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk |
0.275 in (6.99 mm) |
e3 |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; PSE |
125 °C (257 °F) |
|||||||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
63 V |
63 V |
1.5 A |
Wraparound |
125 mJ |
-55 °C (-67 °F) |
Tin Lead Over Nickel |
50 A |
429 |
Rated Breaking Capacity at 63 VDC: 50 A |
Tape And Reel |
0.125 in (3.18 mm) |
0.06 in (1.52 mm) |
e0 |
0.125 x 0.06 x 0.045 in (3.18 x 1.52 x 1.14 mm) |
0.045 in (1.14 mm) |
CSA; UL |
90 °C (194 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Pure Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
1.5 A |
Pin Wire |
-55 °C (-67 °F) |
Matte Tin |
35 A |
4 h |
0.8 |
Tape And Reel |
0.57 in (14.48 mm) |
e3 |
250 V |
2AG |
0.57 x 0.57 in (14.48 x 14.48 mm) |
0.57 in (14.48 mm) |
CE, CSA, UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
0253 |
Rated Breaking Capacity at 125 VDC: 300 A |
Bulk |
0.103 in (2.61 mm) |
e3 |
0.103 x 0.28 in (2.61 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
32 V |
1.5 A |
Pin Wire |
2.35 J |
35 A |
0.276 in (7 mm) |
0.276 x 1.275 in (7 x 32.39 mm) |
1.275 in (32.39 mm) |
CSA; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
1.5 A |
Pin Wire |
-55 °C (-67 °F) |
Tin/Lead |
50 A |
3.94 |
0.135 in (3.43 mm) |
e0 |
125 V |
Pico |
0.135 x 0.28 in (3.43 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA, PSE, UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
1.5 A |
End Cap |
2.55 J |
-55 °C (-67 °F) |
Tin/Lead |
300 A |
481 |
Rated Breaking Capacity at 125 VDC: 300 A |
Box |
e0 |
Alarm |
CSA; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
398 mJ |
-55 °C (-67 °F) |
Pure Tin |
50 A |
Bulk |
0.155 in (3.94 mm) |
0.155 x 0.28 in (3.94 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
251 |
Rated Breaking Capacity at 125 VDC: 300 A |
Bulk |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1.5 A |
End Cap |
15 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.177 in (4.5 mm) |
e3 |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
63 V |
1.5 A |
Wraparound |
230 mJ |
50 A |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
1.5 A |
End Cap |
2.55 J |
-55 °C (-67 °F) |
300 A |
5 m |
0.701 in (17.8 mm) |
0.228 in (5.8 mm) |
125 V |
Alarm; Indicator |
0.772 in (19.6 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
251 |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.5 A |
End Cap |
800 mJ |
100 A |
225 |
Bulk |
0.177 in (4.5 mm) |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.57 in (14.48 mm) |
CSA; METI; PSE; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
1.5 A |
Pin Wire |
40.1 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.275 in (6.99 mm) |
e3 |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.5 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; QPL; UL |
Slow |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Pure Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Bulk |
0.11 in (2.8 mm) |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
1.5 A |
Wraparound |
180 mJ |
50 A |
UL |
125 °C (257 °F) |
Slow |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
-55 °C (-67 °F) |
Tin |
10 kA |
Bulk |
1.273 in (32.34 mm) |
e3 |
1.273 x 0.275 in (32.34 x 6.98 mm) |
0.275 in (6.98 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
1.5 A |
Pin Wire |
15 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.185 in (4.7 mm) |
e3 |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
1.5 A |
Wraparound |
110 mJ |
50 A |
RF0437-000 |
UL |
125 °C (257 °F) |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
J Bend |
650 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
100 ms |
Pre Arcing Time: Open within 0.1 s at 300% Rated Current |
0.65 |
Tape And Reel |
0.285 in (7.24 mm) |
0.17 in (4.32 mm) |
e3 |
125 V |
Pico |
0.285 x 0.17 x 0.12 in (7.24 x 4.32 x 3.05 mm) |
0.12 in (3.05 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
350 V |
1.5 A |
End Cap |
800 mJ |
-55 °C (-67 °F) |
Nickel |
100 A |
Bulk |
0.185 in (4.7 mm) |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
1.5 A |
Pin Wire |
15 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Tape And Reel |
0.185 in (4.7 mm) |
e3 |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
881 mJ |
Tin Lead |
50 A |
674 |
0.154 in (3.9 mm) |
e0 |
0.154 x 0.433 in (3.9 x 11 mm) |
0.433 in (11 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
3.94 J |
-55 °C (-67 °F) |
Pure Tin |
50 A |
Ammo Pack |
0.135 in (3.43 mm) |
0.135 x 0.28 in (3.43 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
587 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
1 s |
Rated Breaking Capacity at 125 VDC: 300 A |
0.587 |
Ammo Pack |
0.11 in (2.8 mm) |
Supplemental |
e3 |
125 V |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
1.5 A |
End Cap |
2.55 J |
-55 °C (-67 °F) |
Tin |
300 A |
5 m |
0.839 in (21.3 mm) |
0.228 in (5.8 mm) |
e3 |
125 V |
Alarm; Indicator |
0.772 in (19.6 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
398 mJ |
-55 °C (-67 °F) |
Pure Tin |
50 A |
0263 |
Ammo Pack |
0.155 in (3.94 mm) |
0.155 x 0.28 in (3.94 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
1.5 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
500 V |
Midget |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Slow |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
1.5 A |
Gull Wing |
540 mJ |
-55 °C (-67 °F) |
Tin Lead |
50 A |
202 |
Tape And Reel |
0.372 in (9.45 mm) |
0.25 in (6.35 mm) |
e0 |
0.372 x 0.25 x 0.165 in (9.45 x 6.35 x 4.19 mm) |
0.165 in (4.19 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
1.61 J |
-55 °C (-67 °F) |
50 A |
471 |
Rated Breaking Capacity at 125 VDC: 50 A |
Tape And Reel |
0.095 in (2.41 mm) |
0.095 x 0.28 in (2.41 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; METI; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
1.5 A |
Wraparound |
95 mJ |
-55 °C (-67 °F) |
35 A |
4 h |
0.095 |
0.069 in (1.75 mm) |
0.037 in (0.95 mm) |
32 V |
0603 |
0.069 x 0.037 x 0.019 in (1.75 x 0.95 x 0.48 mm) |
0.019 in (0.48 mm) |
UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
853 mJ |
Tin/Lead |
50 A |
e0 |
125 V |
Nano |
CSA; UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
3.94 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Tape And Reel |
0.28 in (7.11 mm) |
e3 |
0.28 x 0.135 in (7.11 x 3.43 mm) |
0.135 in (3.43 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Slow |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
1.5 A |
Wraparound |
15.21 J |
-55 °C (-67 °F) |
50 A |
2 m |
Pre Arcing Time: Open within 120 s at 250% Rated Current |
Tape And Reel |
0.429 in (10.9 mm) |
0.189 in (4.8 mm) |
Nano |
0.189 in (4.8 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
1.5 A |
Wraparound |
35 A |
UL |
125 °C (257 °F) |
Fast |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
1.5 A |
Wraparound |
52.6 mJ |
-55 °C (-67 °F) |
Tin Lead Over Nickel |
35 A |
4 h |
Rated Breaking Capacity at 32 VDC: 35 A |
0.052 |
Tape And Reel |
0.063 in (1.6 mm) |
0.032 in (0.81 mm) |
Supplemental |
e0 |
32 V |
48 mΩ |
0603 |
0.063 x 0.032 x 0.012 in (1.6 x 0.81 x 0.31 mm) |
0.012 in (0.31 mm) |
CSA; UL |
90 °C (194 °F) |
Very Fast |
|||||
Littelfuse |
Electric Fuse |
Surface Mount |
63 V |
63 V |
1.5 A |
Wraparound |
298 mJ |
-55 °C (-67 °F) |
50 A |
4 h |
Pre Arcing Time: Open within 0.002 s at 800% 1.5a |
0.298 |
0.125 in (3.18 mm) |
0.06 in (1.52 mm) |
63 V |
56 mΩ |
1206 |
0.125 x 0.06 x 0.045 in (3.18 x 1.52 x 1.14 mm) |
0.045 in (1.14 mm) |
CSA; UL |
90 °C (194 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
1.5 A |
Pin Wire |
15 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.185 in (4.7 mm) |
e3 |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
1.5 A |
End Cap |
-55 °C (-67 °F) |
10 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1.5 A |
200 kA |
FLNR |
Rated Breaking Capacity at 125 VDC: 20000 A |
CSA; UL |
Time Delay |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
1.5 A |
End Cap |
40.1 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.25 in (6.35 mm) |
e3 |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
2.35 J |
-55 °C (-67 °F) |
Tin |
100 A |
318 |
Bulk |
0.275 in (6.99 mm) |
e3 |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
3.94 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
3.94 |
Bulk |
0.135 in (3.43 mm) |
e3 |
125 V |
Pico |
0.135 x 0.28 in (3.43 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1.5 A |
Pin Wire |
1.61 J |
-55 °C (-67 °F) |
Tin |
50 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.5 A |
Pin Wire |
398 mJ |
-55 °C (-67 °F) |
Pure Tin |
50 A |
Bulk |
0.155 in (3.94 mm) |
0.155 x 0.28 in (3.94 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.