Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
10 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
10 A |
End Cap |
80 kA |
LDN |
3 in (76.2 mm) |
3 x 18.875 in (76.2 x 479.43 mm) |
18.875 in (479.43 mm) |
Medium |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
10 A |
End Cap |
200 kA |
Rated Breaking Capacity at 450 VDC: 20000 A |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
26 J |
-40 °C (-40 °F) |
50 A |
Bulk |
0.335 in (8.5 mm) |
250 V |
60 s |
0.315 in (8 mm) |
CSA; UL |
70 °C (158 °F) |
Very Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
568 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
20 ms |
568 |
Bulk |
0.217 in (5.5 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CE; CSA; KC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
251 |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
10 A |
End Cap |
760 J |
-55 °C (-67 °F) |
300 A |
Bulk |
1.25 in (31.75 mm) |
Indicator |
1.25 x 0.25 in (31.75 x 6.35 mm) |
0.25 in (6.35 mm) |
UL |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
10 A |
End Cap |
0.25 in (6.35 mm) |
32 V |
1AG |
0.625 in (15.875 mm) |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
10 A |
End Cap |
24.2 J |
-55 °C (-67 °F) |
50 A |
5 s |
Rated Breaking Capacity at 32 VDC: 300 A, Pre Arcing Time: Open within 5 s at 200% Rated Current |
Tape And Reel |
0.08 in (2.032 mm) |
32 V |
Nano |
0.225 in (5.715 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
10 A |
1.3 kJ |
200 kA |
LVSP |
1.5 in (38.1 mm) |
1.5 in (38.1 mm) |
UL |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
10 A |
Tab/Blade |
80 kA |
4.75 in (120.65 mm) |
4.75 x 15.13 in (120.65 x 384.3 mm) |
15.13 in (384.3 mm) |
Medium |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
133 J |
-55 °C (-67 °F) |
Tin |
200 A |
Pre-Arcing Time: Open within 0.4 s, at 200% Rated Current |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KTL; PSE; UL |
125 °C (257 °F) |
Medium |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
154.34 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
0.228 in (5.8 mm) |
e3 |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; KTL; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
10 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
600 V |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
10 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
10 A |
End Cap |
380.3 J |
-55 °C (-67 °F) |
300 A |
5 m |
0.839 in (21.3 mm) |
0.228 in (5.8 mm) |
125 V |
Alarm; Indicator |
0.772 in (19.6 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
351.037 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
215P |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KTL; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
290.664 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; PSE |
125 °C (257 °F) |
Medium |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
190 J |
-25 °C (-13 °F) |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
TR5 |
0.315 in (8 mm) |
70 °C (158 °F) |
Time Lag |
||||||||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
350 V |
125 V |
10 A |
Gull Wing |
93 J |
-40 °C (-40 °F) |
Tin |
100 A |
Rated Breaking Capacity at 125 VDC: 50 A |
Tape And Reel |
0.43 in (10.92 mm) |
0.345 in (8.76 mm) |
e3 |
0.43 x 0.345 x 0.15 in (10.92 x 8.76 x 3.81 mm) |
0.15 in (3.81 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
10 A |
End Cap |
10 kA |
UL |
Time Delay |
|||||||||||||||||||||||
Littelfuse |
Electric Fuse |
10 A |
End Cap |
H |
500 V |
Midget |
Fast |
||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
224 J |
50 A |
4 h |
224 |
Bulk |
0.154 in (3.9 mm) |
250 V |
0.154 x 0.433 in (3.9 x 11 mm) |
0.433 in (11 mm) |
CSA; UL |
Slow |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
251 |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
-55 °C (-67 °F) |
50 A |
276 |
Rated Breaking Capacity at 125 VDC: 300 A |
0.093 in (2.36 mm) |
0.093 x 0.28 in (2.36 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel |
0.095 in (2.41 mm) |
e3 |
0.095 x 0.28 in (2.41 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
154.34 J |
-55 °C (-67 °F) |
Tin |
1.2 kA |
Bulk |
0.228 in (5.8 mm) |
e3 |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; KTL; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.103 in (2.61 mm) |
e3 |
0.103 x 0.28 in (2.61 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
10 A |
End Cap |
380.3 J |
-55 °C (-67 °F) |
Tin |
300 A |
5 m |
0.701 in (17.8 mm) |
0.228 in (5.8 mm) |
e3 |
125 V |
Alarm; Indicator |
0.772 in (19.6 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
10 A |
Tab/Blade |
Silver |
Rated Breaking Capacity at 170 VDC: 100000 |
0.563 in (14.3 mm) |
e4 |
0.563 x 1.367 in (14.3 x 34.72 mm) |
1.367 in (34.72 mm) |
UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
88.5 J |
50 A |
5 s |
0.154 in (3.9 mm) |
0.142 x 0.394 in (3.6 x 10 mm) |
0.433 in (11 mm) |
CSA; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
0.406 x 1.375 in (10.31 x 34.93 mm) |
1.375 in (34.93 mm) |
CSA; UL |
Fast |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
440 V |
10 A |
End Cap |
500 J |
-25 °C (-13 °F) |
Nickel |
1 kA |
Bulk |
0.248 in (6.3 mm) |
440 V |
20 ms |
3AB |
0.248 x 1.26 in (6.3 x 32 mm) |
1.26 in (32 mm) |
UL |
70 °C (158 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Pure Tin |
50 A |
253 |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
568 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk |
0.228 in (5.8 mm) |
e3 |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; IEC; KC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
Littelfuse |
Electric Fuse |
10 A |
-40 °C (-40 °F) |
50 A |
4 h |
564 |
0.335 in (8.5 mm) |
250 V |
0.335 x 0.333 in (8.5 x 8.45 mm) |
0.333 in (8.45 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
10 A |
Tab/Blade |
80 kA |
4.75 in (120.65 mm) |
4.75 x 16.131 in (120.65 x 409.72 mm) |
16.131 in (409.72 mm) |
Medium |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Tin |
50 A |
0253 |
Rated Breaking Capacity at 125 VDC: 300 A |
Bulk |
0.103 in (2.61 mm) |
e3 |
0.103 x 0.28 in (2.61 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Pin Wire |
154.34 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
30 ms |
154.34 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
20 J |
-25 °C (-13 °F) |
Nickel |
1 kA |
Bulk |
0.205 in (5.2 mm) |
250 V |
1 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
70 °C (158 °F) |
Very Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
10 A |
End Cap |
80 kA |
10E-1C-2.75 |
3 in (76.2 mm) |
3 x 10.874 in (76.2 x 276.2 mm) |
10.874 in (276.2 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A, Pre Arcing Time: Open within 4 ms at 1000% Rated Current |
Tape And Reel |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
10 A |
End Cap |
278.39 J |
-55 °C (-67 °F) |
100 kA |
701 µs |
Rated Breaking Capacity at 600 VDC: 50000 A |
Bulk |
0.406 in (10.31 mm) |
1.2 ms |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA, IEC, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
158.5 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
216 |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KTL; PSE; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
2.75 KV |
10 A |
End Cap |
80 kA |
5 m |
3 in (76.2 mm) |
Striker |
3 x 10.875 in (76.2 x 276.23 mm) |
10.874 in (276.2 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
10 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
600 V |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
10 A |
End Cap |
211.667 J |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
150 J |
-25 °C (-13 °F) |
1.5 kA |
Bulk |
0.205 in (5.2 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CUL; UL |
70 °C (158 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.