Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
160 A |
Tab/Blade |
2.756 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
160 A |
Tab/Blade |
1.6 J |
200 kA |
LA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
160 A |
Tab/Blade |
1.359 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
160 A |
End Cap |
2.6 J |
100 kA |
2.008 in (51 mm) |
2.008 in (51 mm) |
Indicator |
2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
160 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
960 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
e3 |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
160 A |
Tab/Blade |
19 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
160 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.921 in (74.2 mm) |
1.969 in (50 mm) |
Indicator |
2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
160 A |
Tab/Blade |
19 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
160 A |
Tab/Blade |
10 kA |
1.06 in (26.92 mm) |
4.72 in (119.88 mm) |
Time Delay |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
160 A |
Tab/Blade |
60.1 kJ |
200 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
1.5 in (38.1 mm) |
Midget |
1.5 x 3 in (38.1 x 76.2 mm) |
3.012 in (76.5 mm) |
CE; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
160 A |
Tab/Blade |
1.359 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
48 V |
160 A |
Tab/Blade |
2.5 kA |
1.535 in (39 mm) |
1.195 in (30.35 mm) |
48 V |
1.535 x 0.683 in (39 x 17.35 mm) |
0.683 in (17.35 mm) |
UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
160 A |
Tab/Blade |
60.1 kJ |
200 kA |
10 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
160 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.22 in (56.4 mm) |
1.181 in (30 mm) |
Indicator |
2.22 x 1.181 x 2.126 in (56.4 x 30 x 54 mm) |
2.126 in (54 mm) |
VDE |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
160 A |
End Cap |
2.6 J |
100 kA |
2.008 in (51 mm) |
2.008 in (51 mm) |
2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
160 A |
Tab/Blade |
-40 °C (-40 °F) |
960 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
160 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.1 in (53.34 mm) |
1.181 in (30 mm) |
Indicator |
2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm) |
2.76 in (70.11 mm) |
VDE |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
160 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.22 in (56.4 mm) |
1.181 in (30 mm) |
Indicator |
2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm) |
2.835 in (72 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
80 V |
160 A |
Wraparound |
82.8 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.232 in (31.3 mm) |
0.984 in (25 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
160 A |
Threaded |
1.359 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
160 A |
Tab/Blade |
2.5 J |
100 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 2.854 in (40 x 40 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
160 A |
Threaded |
2.756 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
160 A |
Threaded |
2.377 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
160 A |
Tab/Blade |
13.704 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.