180 mA Fuses 18

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0481.180HXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180H

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

Tin

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180VX

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180V

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

Tin

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

04810180VXLP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.839 in (21.3 mm)

0.228 in (5.8 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

0481.180VXLM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180VXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

Tin

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

e3

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180VXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

04810180H

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.701 in (17.8 mm)

0.209 in (5.3 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

0481.180HXLM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180HXM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180HX

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180VM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0481.180HM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

40 mJ

-55 °C (-67 °F)

40 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

04810180HXL

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.839 in (21.3 mm)

0.228 in (5.8 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

04810180VP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

300 A

5 m

Bulk

0.701 in (17.8 mm)

0.209 in (5.3 mm)

Alarm

0.772 in (19.6 mm)

CSA; UL

90 °C (194 °F)

0481.180

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

8.08 mJ

-55 °C (-67 °F)

Tin/Lead

300 A

481

Rated Breaking Capacity at 125 VDC: 300 A

Box

e0

Alarm

CSA; UL

125 °C (257 °F)

481.180

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

180 mA

End Cap

481

Alarm

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.