187.5 mA Fuses 6

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK/AGX-3/16

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

187.5 mA

End Cap

Nickel

35 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

Box

0.25 in (6.35 mm)

250 V

0.248 x 1 in (6.3 x 25.4 mm)

0.25 x 1.042 in (6.35 x 26.47 mm)

1 in (25.4 mm)

CUL

Fast

0FLQ.187HXR

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

End Cap

10 kA

0.406 in (10.31 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

7945816017

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

End Cap

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

125 °C (257 °F)

Time Delay

KLDR3/16

Littelfuse

Electric Fuse

187.5 mA

End Cap

200 kA

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Lag

7945894951

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

Tab/Blade

-55 °C (-67 °F)

10 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE, UL

125 °C (257 °F)

Time Delay

FLQ.187R

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

187.5 mA

End Cap

10 kA

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.