2.8 A Fuses 82

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

ATDR2-8/10

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FNQ-R-2-8/10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

2.8 A

End Cap

Nickel

200 kA

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

ATQR2-8/10

Mersen S A

Electric Fuse

Inline/Holder

600 V

2.8 A

End Cap

200 kA

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

LP-CC-2-8/10

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

FNM-2-8/10

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

100 A

Box

0.406 in (10.3 mm)

250 V

Midget

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

031302.8HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

170 J

-55 °C (-67 °F)

Nickel

100 A

4 h

170

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

32502.8P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

170 J

Matte Tin

100 A

325P

0.275 in (6.99 mm)

e3

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; PSE; UL

Slow

LLSRK02.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

LLSRK2.80

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

20 kA

Rated Breaking Capacity at 300 VDC: 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

Time Delay

LLNRK02.8

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

FLSR02.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; QPL; UL

Time Delay

FLSR2.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

KLDR02.8

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

21.28 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

FLSR02.8T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

31502.8

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

2.8 A

Pin Wire

170 J

Tin/Lead

100 A

0.275 in (6.985 mm)

e0

0.275 x 1.275 in (6.985 x 32.385 mm)

1.275 in (32.385 mm)

CE; CSA; PSE; UL

Slow

032502.8HXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

2.8 A

Pin Wire

170 J

-55 °C (-67 °F)

Tin

100 A

4 h

170

Bulk

0.275 in (6.99 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

IDSR02.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.8 A

200 kA

IDSR

Rated Breaking Capacity at 600 VDC: 20000 A

Indicator

CSA; UL

Time Delay

031502.8MXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

269 J

-60 °C (-76 °F)

100 A

5 s

Bulk

0.275 in (6.99 mm)

3AG

1.273 x 0.275 in (32.34 x 6.98 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

032502.8VXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

2.8 A

Pin Wire

-55 °C (-67 °F)

Tin

4 h

170

0.275 in (6.985 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.985 x 32.72 mm)

1.288 in (32.72 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Time Lag

IDSR02.8T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLA2-8/10

Littelfuse

Electric Fuse

Inline/Holder

125 V

2.8 A

End Cap

10 kA

0.406 in (10.31 mm)

Indicator

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

UL

Slow

SOO2.80

Littelfuse

Electric Fuse

Inline/Holder

125 V

2.8 A

End Cap

10 kA

UL

Time Delay

CCMR02.8HXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LLSRK02.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

Time Delay

JTD02.8ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CSA; UL

Time Delay

3252.8MHXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

125 V

2.8 A

Pin Wire

170 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.275 in (6.99 mm)

e3

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

31302.8

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2.8 A

End Cap

170 J

100 A

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; METI; PSE; UL

Slow

032502.8MXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

125 V

2.8 A

Pin Wire

232 J

-55 °C (-67 °F)

Tin

100 A

5 s

Rated Breaking Capacity at 125 VDC: 10000 A

170

Bulk

0.275 in (6.985 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Delay

032502.8MX52LP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

232 J

-55 °C (-67 °F)

Tin

4 h

170

0.275 in (6.985 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.985 x 32.72 mm)

1.288 in (32.72 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Time Lag

CCMR02.8T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

CCMR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

59302.8

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

2.8 A

End Cap

Nickel

593

59302.8S

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

Silver

0.394 in (10 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

MIL-PRF-15160

Time Delay

031302.8VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

170 J

-55 °C (-67 °F)

Nickel

100 A

313

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

FLNR2.8ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.8 A

End Cap

200 kA

0.563 in (14.3 mm)

Indicator

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

LMF02.8

Littelfuse

Electric Fuse

Inline/Holder

300 V

2.8 A

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Time Delay

031302.8MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

269 J

-60 °C (-76 °F)

Nickel

100 A

5 s

170

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

1.25 x 0.25 in (31.75 x 6.35 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

JTD28/10ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

0JTD02.8TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

LLSRK2.80ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

LLSRK

Rated Breaking Capacity at 300 VDC: 20000 A

Indicator

CSA; UL

Time Delay

031502.8MXBP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

269 J

-55 °C (-67 °F)

100 A

5 s

Bulk

0.275 in (6.985 mm)

3AG

1.275 in (32.39 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Slow

KLDR02.8T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

FLM28/10

Littelfuse

Electric Fuse

Inline/Holder

250 V

2.8 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Slow

32502.8

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

170 J

Tin/Lead

0.275 in (6.99 mm)

e0

0.275 x 1.275 in (6.99 x 32.39 mm)

1.275 in (32.39 mm)

CSA; UL

Slow

3262.8MVXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

2.8 A

End Cap

170 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

LMF2-8/10

Littelfuse

Electric Fuse

Inline/Holder

300 V

2.8 A

End Cap

10 kA

0.61 in (15.49 mm)

0.61 x 1.82 in (15.49 x 46.23 mm)

1.82 in (46.23 mm)

CSA; UL

Time Delay

031502.8VXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.8 A

Pin Wire

170 J

-55 °C (-67 °F)

Matte Tin

100 A

315

Bulk

0.275 in (6.99 mm)

e3

0.275 x 1.275 in (6.99 x 32.39 mm)

1.275 in (32.39 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

CCMR02.8TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

2.8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

3252.8MMXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

125 V

2.8 A

Pin Wire

170 J

-55 °C (-67 °F)

Matte Tin

100 A

Rated Breaking Capacity at 125 VDC: 10000 A

Bulk

0.275 in (6.99 mm)

e3

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.