Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
316 mJ |
-55 °C (-67 °F) |
Tin |
4 h |
0.213 |
0.275 in (6.985 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.985 x 32.72 mm) |
1.288 in (32.72 mm) |
CE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
200 mA |
Pin Wire |
100 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 m |
0.1 |
Bulk |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
450 mJ |
-25 °C (-13 °F) |
35 A |
Bulk |
0.248 in (6.3 mm) |
5 s |
0.248 x 1.26 in (6.3 x 32 mm) |
1.26 in (32 mm) |
CSA; UL |
70 °C (158 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
8.67 mJ |
-55 °C (-67 °F) |
35 A |
5 s |
Bulk |
0.197 in (5 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CSA, CE, UL |
125 °C (257 °F) |
Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
200 mA |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; QPL; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
4.8 mJ |
-55 °C (-67 °F) |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
Ammo Pack |
0.103 in (2.61 mm) |
Pico |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
120 mJ |
-25 °C (-13 °F) |
80 A |
5 ms |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CUL; UL |
70 °C (158 °F) |
Medium Time Lag |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
125 V |
200 mA |
End Cap |
57.6 mJ |
-55 °C (-67 °F) |
Tin |
40 A |
5 m |
0.701 in (17.8 mm) |
0.228 in (5.8 mm) |
e3 |
125 V |
Alarm; Indicator |
0.772 in (19.6 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Wire |
8.67 mJ |
-55 °C (-67 °F) |
35 A |
5 s |
Bulk |
0.197 in (5 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CSA, CE, UL |
125 °C (257 °F) |
Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
84 mJ |
-40 °C (-40 °F) |
1.5 kA |
181 |
Tape And Reel |
0.232 in (5.9 mm) |
10 ms |
0.232 x 0.827 in (5.9 x 21 mm) |
0.827 in (21 mm) |
CNCA; CUL; IEC; UL |
85 °C (185 °F) |
Time Lag |
||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Wire |
4.09 mJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
4.09 mJ |
-55 °C (-67 °F) |
Tin |
10 kA |
4 h |
Bulk |
0.25 in (6.35 mm) |
e3 |
125 V |
Micro |
0.25 x 0.35 in (6.35 x 8.89 mm) |
0.35 in (8.89 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
-55 °C (-67 °F) |
Pure Tin |
50 A |
300 ms |
Pre-Arcing Time: Open within 0.3 s at 300% Rated Current |
Tape And Reel |
0.11 in (2.8 mm) |
Pico |
0.28 in (7.11 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
230 mJ |
-25 °C (-13 °F) |
Nickel |
80 A |
Bulk |
0.205 in (5.2 mm) |
250 V |
5 ms |
0.197 x 0.984 in (5 x 25 mm) |
Indicator |
0.205 x 0.984 in (5.2 x 25 mm) |
0.984 in (25 mm) |
70 °C (158 °F) |
Medium Time Lag |
||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
200 mA |
Pin Wire |
370 mJ |
1.5 kA |
10 ms |
0.207 in (5.25 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CSA; CUL; SEMKO; SEV; PSE; VDE; UL |
Time Lag |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
16.5 mJ |
-55 °C (-67 °F) |
35 A |
5 s |
Bulk |
0.25 in (6.35 mm) |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
270 mJ |
-55 °C (-67 °F) |
Nickel |
35 A |
313 |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
20 mJ |
Tin Lead |
35 A |
0.154 in (3.9 mm) |
e0 |
0.154 x 0.433 in (3.9 x 11 mm) |
0.433 in (11 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
341 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk; Tape And Reel |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KTL; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
200 mJ |
-40 °C (-40 °F) |
Matte Tin |
35 A |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
20 ms |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; KTL; SEMKO; UL; VDE |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
146 mJ |
-40 °C (-40 °F) |
Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
100 mJ |
-40 °C (-40 °F) |
Tin |
50 A |
Tape And Reel |
0.335 in (8.5 mm) |
e3 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA; UL |
85 °C (185 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
4.8 mJ |
-55 °C (-67 °F) |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
Bulk |
0.11 in (2.8 mm) |
125 V |
Pico |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
120 mJ |
-25 °C (-13 °F) |
80 A |
5 ms |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
Tape And Reel |
0.232 in (5.9 mm) |
0.197 x 0.787 in (5 x 20 mm) |
Indicator |
0.205 x 0.787 in (5.2 x 20 mm) |
0.827 in (21 mm) |
CUL; UL |
70 °C (158 °F) |
Medium Time Lag |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
200 mA |
End Cap |
-55 °C (-67 °F) |
10 kA |
0.406 in (10.31 mm) |
500 V |
Midget |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
165 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
4 h |
0.16 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
4.8 mJ |
-55 °C (-67 °F) |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
Bulk |
0.11 in (2.8 mm) |
125 V |
Pico |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
165 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
4 h |
0.16 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; KC; UL |
125 °C (257 °F) |
Time Lag |
||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
300 mJ |
-25 °C (-13 °F) |
150 A |
Bulk |
0.213 in (5.4 mm) |
20 ms |
0.197 x 0.787 in (5 x 20 mm) |
0.827 in (21 mm) |
BSI; CUL; IEC; SEMKO; UL; VDE |
70 °C (158 °F) |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
200 mA |
Pin Wire |
270 mJ |
Tin/Lead |
35 A |
0.275 in (6.985 mm) |
e0 |
0.275 x 1.275 in (6.985 x 32.385 mm) |
1.275 in (32.385 mm) |
CE; CSA; PSE; UL |
Slow |
||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
200 mA |
Pin Wire |
16.5 mJ |
Tin Lead |
35 A |
0.276 in (7 mm) |
e0 |
0.276 x 1.275 in (7 x 32.39 mm) |
1.275 in (32.39 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
200 mJ |
-40 °C (-40 °F) |
Matte Tin |
35 A |
Bulk |
0.335 in (8.5 mm) |
e3 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; KTL; SEMKO; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||||||
Littelfuse |
Electric Fuse |
200 mA |
End Cap |
200 kA |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 0.02 s at 1000% Rated Current |
Tape And Reel |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 0.02 s at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
200 mA |
End Cap |
-55 °C (-67 °F) |
100 kA |
4 m |
Pre Arcing Time: Clear within 4 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 0.02 s at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
63 V |
200 mA |
Pin Wire |
4.2 mJ |
-25 °C (-13 °F) |
Matte Tin |
50 A |
1 m |
Pre Arcing Time: Open within 60 s at 200% Rated Current |
Bulk |
0.236 in (6 mm) |
e3 |
0.315 in (8 mm) |
CSA; UL |
70 °C (158 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 0.02 s at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
63 V |
200 mA |
Pin Wire |
4.2 mJ |
-25 °C (-13 °F) |
50 A |
1 m |
Pre Arcing Time: Open within 60 s at 200% Rated Current |
Ammo Pack; Tape |
0.236 in (6 mm) |
0.315 in (8 mm) |
CSA; UL |
70 °C (158 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Pre Arcing Time: Open within 0.02 s at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
200 mA |
End Cap |
-55 °C (-67 °F) |
100 kA |
4 m |
Pre Arcing Time: Clear within 4 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
200 mA |
End Cap |
10 kA |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.235 in (5.97 mm) |
Micro |
0.29 in (7.37 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.235 in (5.97 mm) |
Micro |
0.29 in (7.37 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
200 mA |
End Cap |
225 mJ |
-55 °C (-67 °F) |
35 A |
20 ms |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
200 mA |
End Cap |
10 kA |
2 m |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.378 in (10 x 35 mm) |
1.375 in (34.925 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
200 mA |
Pin Wire |
4.09 mJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.