225 A Fuses 121

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

MEV100A225-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

100 kA

80 ms

Bulk

1.5 in (38.1 mm)

2.843 in (72.2 mm)

IATF 16949; UL

0JTD225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

0JTD225.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

3.374 in (85.7 mm)

CSA; UL

Time Delay

JTD225

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

LLNRK225

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

2.094 x 8.626 in (53.2 x 219.1 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

EVK40-225

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

7.162 kJ

-40 °C (-40 °F)

25 kA

Box

1.5 in (38.1 mm)

2.843 in (72.2 mm)

UL

125 °C (257 °F)

LA100P225-4

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

225 A

Tab/Blade

91 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

2 in (50.8 mm)

2 x 3.469 in (50.8 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

JLLN225.X

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

300 V

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

JLLS225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

1.594 in (40.5 mm)

600 V

1.713 in (43.5 mm)

CE; CSA; UL

Fast

298225

Littelfuse

Electric Fuse

Inline/Holder

32 V

225 A

Tab/Blade

257 kJ

2 kA

Rated Breaking Capacity at 32 VDC: 2000 A

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

Slow

0898225.U-1M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

142.5 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0CNN225.V

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

225 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

48 V

3.18 in (80.77 mm)

UL

Very Fast

L50QS225.V

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

225 A

Tab/Blade

5.379 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

1.5 in (38.1 mm)

10 ms

2.093 in (53.16 mm)

CE; CUL; UL

125 °C (257 °F)

Very Fast

0898225.U-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

142.5 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0581225

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

225 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

48 V

1.535 x 0.683 in (39 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

0998225.UX-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

142.5 kJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

CNN225E

Littelfuse

Electric Fuse

Inline/Holder

125 V

80 V

225 A

Tab/Blade

2.7 kA

3.181 in (80.8 mm)

3.18 in (80.77 mm)

CUL; UL

Very Fast

FLNR225

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

2 in (50.8 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

JTD225ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

2.126 x 3.374 in (54 x 85.7 mm)

3.374 in (85.7 mm)

CSA; UL

Time Delay

0998225.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

250 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.21 mm)

0.75 in (19.05 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

0898225.U-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

142.5 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

5NLE2225E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

225 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 17.875 in (162.05 x 454.03 mm)

17.875 in (454.03 mm)

Medium

FLSR225ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 11.626 in (65.9 x 295.3 mm)

11.626 in (295.3 mm)

CSA; QPL; UL

Time Delay

225E-3CL-15.5

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

225 A

Tab/Blade

60 kA

11.56 in (293.62 mm)

11.56 x 19.1 in (293.62 x 485.14 mm)

19.1 in (485.14 mm)

Medium

0298225.UXP-2M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

225 A

Tab/Blade

135.3 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

0298225.UXP-1M6

Littelfuse

Electric Fuse

Inline/Holder

32 V

225 A

Tab/Blade

135.3 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

0898225.U-NH

Littelfuse

Electric Fuse

Inline/Holder

70 V

225 A

Tab/Blade

142.5 kJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

225E-2CL-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

225 A

Tab/Blade

80 kA

7.94 in (201.68 mm)

7.94 x 16.131 in (201.68 x 409.72 mm)

16.131 in (409.72 mm)

Medium

0CNL225.V

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

225 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

UL

Fast

NLS225

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

225 A

Tab/Blade

50 kA

Rated Breaking Capacity at 500 VDC; 50000

2.594 in (65.9 mm)

2.594 x 7.878 in (65.9 x 200.1 mm)

7.878 in (200.1 mm)

CSA; UL

3998225.ZXM10

Littelfuse

Electric Fuse

Surface Mount

80 V

225 A

Wraparound

126.9 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

EV1K225.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

14 kJ

-40 °C (-40 °F)

30 kA

Bulk

1.218 in (30.94 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

EV1K225

Littelfuse

Electric Fuse

Inline/Holder

1 KV

225 A

Tab/Blade

14 kJ

-40 °C (-40 °F)

30 kA

Bulk

1.218 in (30.94 mm)

2.875 in (73.03 mm)

125 °C (257 °F)

30EV225.ZXBDM

Littelfuse

Electric Fuse

Inline/Holder

500 V

225 A

Tab/Blade

41 kJ

-40 °C (-40 °F)

30 kA

50 ms

1.181 in (30 mm)

2.047 in (52 mm)

CSA; UL

125 °C (257 °F)

Time Delay

FLNR225.XXID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

2 in (50.8 mm)

Indicator

8.626 in (219.1 mm)

CSA; UL

Time Delay

FLNR225.X

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

2 in (50.8 mm)

8.626 in (219.1 mm)

CSA; UL

Time Delay

FLSR225.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.543 in (64.6 mm)

Indicator

11.626 in (295.3 mm)

CSA; UL

Time Delay

JLLN225P

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

LLNRK225.V

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL; QPL

Time Delay

0RLS225.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

225 A

Tab/Blade

10 kA

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CE; CSA; UL

0RLN225.T

Littelfuse

Electric Fuse

Inline/Holder

250 V

225 A

Tab/Blade

10 kA

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL

KLSR0225

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

11.626 in (295.3 mm)

CE; CSA; UL

Fast

KLNR0225

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.094 in (53.2 mm)

8.626 in (219.1 mm)

CE; CSA; UL

Fast

0KLC225.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

225 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

2 in (50.8 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L70QS225

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

225 A

Tab/Blade

9.226 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

2 in (50.8 mm)

2.844 in (72.24 mm)

CUL; UL

125 °C (257 °F)

Very Fast

LLSRK225.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

225 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

11.626 in (295.3 mm)

CE; CSA; UL; QPL

Time Delay

0298225.ZXEH-LT

Littelfuse

Electric Fuse

Inline/Holder

32 V

225 A

Tab/Blade

317 kJ

-40 °C (-40 °F)

2 kA

100 ms

317000

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

1.15 x 0.75 x 0.39 in (29.2 x 19.05 x 9.9 mm)

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

225E-2CL-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

225 A

Tab/Blade

80 kA

7.94 in (201.68 mm)

7.94 x 16.13 in (201.68 x 409.7 mm)

16.13 in (409.7 mm)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.