Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
500 V |
250 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
1.929 in (49 mm) |
1.457 in (37 mm) |
e3 |
0.945 in (24 mm) |
105 °C (221 °F) |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
80 V |
250 A |
End Cap |
2.7 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
450 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 100000 A |
2.11 in (53.59 mm) |
2.11 x 3.38 in (53.59 x 85.85 mm) |
3.38 in (85.85 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
7.75 kJ |
150 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 2.087 in (53 x 53 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
250 A |
Tab/Blade |
10.5 kJ |
50 kA |
Box |
2 in (50.8 mm) |
2 x 2.84 in (50.8 x 72.14 mm) |
2.84 in (72.136 mm) |
CE; CSA; UL |
|||||||||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
9.6 kJ |
-40 °C (-40 °F) |
Tin |
50 kA |
Bulk |
2.913 in (74 mm) |
1.772 in (45 mm) |
e3 |
0.984 in (25 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
250 A |
Tab/Blade |
5.2 kJ |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.969 in (50 mm) |
1.969 x 1.614 in (50 x 41 mm) |
1.614 in (41 mm) |
BS 88; CE |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
2.126 in (54 mm) |
Indicator |
2.126 x 3.346 in (54 x 85 mm) |
7.126 in (181 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
Indicator |
3.236 in (82.2 mm) |
3.236 in (82.2 mm) |
UL |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
2.126 in (54 mm) |
7.126 in (181 mm) |
CSA; IEC; UL |
Time Delay |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Panel Mount |
1.25 KV |
250 A |
Threaded |
9.58 kJ |
150 kA |
Bulk |
2.913 in (74 mm) |
1.567 in (39.8 mm) |
AR |
70 |
Indicator |
1.831 in (46.5 mm) |
CCC; CE; CSA; CUL; EAC; IEC; UL; VDE |
Ultra Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
2.52 in (64 mm) |
J |
600 V |
7.992 in (203 mm) |
IEC, UL |
Time Lag |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
250 A |
Tab/Blade |
200 kA |
3.626 in (92.1 mm) |
3.626 x 1.736 in (92.1 x 44.1 mm) |
1.736 in (44.1 mm) |
CE; CSA; UL |
Very Fast |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
100 kA |
80 ms |
Bulk |
1.5 in (38.1 mm) |
2.843 in (72.2 mm) |
IATF 16949; UL |
|||||||||||||||||||
Mersen S A |
Electric Fuse |
Panel Mount |
1.25 KV |
250 A |
Threaded |
8.9 kJ |
126 kA |
Bulk |
2.913 in (74 mm) |
2.008 in (51 mm) |
Indicator |
2.224 in (56.5 mm) |
CCC; CE; CSA; CUL; EAC; IEC; UL; VDE |
Ultra Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
3.374 in (85.7 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
3.1 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
250 A |
Tab/Blade |
220 kJ |
-40 °C (-40 °F) |
Tin |
2.5 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
e3 |
70 V |
Mega |
0.39 in (9.9 mm) |
ISO |
125 °C (257 °F) |
|||||||||||
Eaton Corporation |
Electric Fuse |
Surface Mount |
125 V |
80 V |
250 A |
Tab/Blade |
2.5 kA |
3.189 in (81 mm) |
Indicator |
3.189 x 0.874 in (81 x 22.2 mm) |
0.874 in (22.2 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
250 A |
Tab/Blade |
389 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
Bulk |
1.15 in (29.2 mm) |
0.748 in (19 mm) |
32 V |
Mega |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.39 in (9.9 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
250 A |
Tab/Blade |
389 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
3.1 kJ |
200 kA |
Box |
2.087 in (53 mm) |
2.087 in (53 mm) |
Indicator |
2.087 x 2.087 x 1.969 in (53 x 53 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Siemens |
Electric Fuse |
Inline/Holder |
690 V |
250 V |
250 A |
Tab/Blade |
-20 °C (-4 °F) |
100 kA |
2.618 in (66.5 mm) |
2.047 in (52 mm) |
Indicator |
2.618 x 2.047 x 2.047 in (66.5 x 52 x 52 mm) |
2.047 in (52 mm) |
CCC; CE; UL |
50 °C (122 °F) |
|||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
250 A |
Tab/Blade |
200 kA |
2.126 in (54 mm) |
7.126 in (181 mm) |
CSA; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
250 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.594 in (40.5 mm) |
1.713 in (43.5 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
250 A |
Tab/Blade |
85.9 kJ |
200 kA |
12 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
2 in (50.8 mm) |
Midget |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; IEC; UL; VDE |
||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
16 kJ |
50 kA |
2.835 in (72 mm) |
1.429 in (36.3 mm) |
0.945 in (24 mm) |
IEC; UL |
||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
4.2 kJ |
200 kA |
Box |
1.772 in (45 mm) |
1.772 in (45 mm) |
Indicator |
1.772 x 1.772 x 1.969 in (45 x 45 x 50 mm) |
1.969 in (50 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
10 kJ |
150 kA |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; DIN 43653; IEC; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
250 A |
Tab/Blade |
85.9 kJ |
200 kA |
12 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
2 in (50.8 mm) |
Midget |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; IEC; UL; VDE |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
250 A |
Tab/Blade |
7.9 kJ |
200 kA |
1.378 in (35 mm) |
0.807 in (20.5 mm) |
1.378 x 0.807 x 1.957 in (35 x 20.5 x 49.7 mm) |
1.957 in (49.7 mm) |
CE; CSA; IEC; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
250 A |
Tab/Blade |
10.999 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
2 in (50.8 mm) |
2.844 in (72.24 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
4.2 kJ |
200 kA |
Box |
1.969 in (50 mm) |
1.772 in (45 mm) |
Indicator |
1.969 x 1.772 x 1.772 in (50 x 45 x 45 mm) |
1.772 in (45 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
26 kJ |
50 kA |
17000 |
Bulk |
2.953 in (75 mm) |
2.087 in (53 mm) |
1 KV |
2.953 x 2.087 x 2.402 in (75 x 53 x 61 mm) |
2.402 in (61 mm) |
CSA; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
250 A |
Tab/Blade |
73 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.362 in (60 mm) |
NH |
2.362 in (60 mm) |
UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
250 A |
Tab/Blade |
292.5 kJ |
-40 °C (-40 °F) |
Matte Tin |
1 kA |
100 ms |
1.142 in (29 mm) |
e3 |
58 V |
1.142 x 0.74 x 0.366 in (29 x 18.8 x 9.3 mm) |
0.37 in (9.4 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
800 V |
250 A |
Tab/Blade |
7.4 kJ |
50 kA |
2.126 in (54 mm) |
1.429 in (36.3 mm) |
0.945 in (24 mm) |
UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
250 A |
Tab/Blade |
200 kA |
Bulk |
2 in (50.8 mm) |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
250 A |
Tab/Blade |
7.094 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Bulk |
1.5 in (38.1 mm) |
500 V |
10 ms |
2.093 in (53.16 mm) |
CE; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
250 A |
Tab/Blade |
7.75 kJ |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
250 A |
Tab/Blade |
31 kJ |
200 kA |
2.52 in (64 mm) |
1.575 in (40 mm) |
Indicator |
2.52 x 1.575 x 2.677 in (64 x 40 x 68 mm) |
2.677 in (68 mm) |
CE; CSA; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
250 A |
End Cap |
7.75 kJ |
100 kA |
2.913 in (74 mm) |
2.087 in (53 mm) |
Indicator |
2.913 x 2.087 x 2.087 in (74 x 53 x 53 mm) |
2.087 in (53 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Panel Mount |
32 V |
250 A |
Wraparound |
160.9 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.232 in (31.3 mm) |
0.984 in (25 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
250 A |
Tab/Blade |
389 kJ |
-40 °C (-40 °F) |
Silver |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
e4 |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
250 A |
Tab/Blade |
10 kA |
2.594 in (65.9 mm) |
2.594 x 7.478 in (65.9 x 189.94 mm) |
7.478 in (189.94 mm) |
UL |
Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
250 A |
Tab/Blade |
60 kA |
11.56 in (293.62 mm) |
11.56 x 19.1 in (293.62 x 485.14 mm) |
19.1 in (485.14 mm) |
Medium |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
250 A |
Tab/Blade |
389 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
1.15 in (29.21 mm) |
0.75 in (19.05 mm) |
1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm) |
0.42 in (10.67 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
250 A |
Tab/Blade |
7.737 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.