Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
30 A |
End Cap |
80 kA |
5NLE-30E |
3 in (76.2 mm) |
3 x 17.874 in (76.2 x 454 mm) |
17.874 in (454 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
-40 °C (-40 °F) |
0.898 in (22.8 mm) |
0.638 in (16.2 mm) |
32 V |
0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm) |
0.846 in (21.5 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
30 A |
End Cap |
4.2 kJ |
-55 °C (-67 °F) |
Matte Tin |
2.5 kA |
2 m |
Bulk |
0.248 in (6.3 mm) |
e3 |
0.236 x 0.984 in (6 x 25 mm) |
0.992 in (25.2 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
2.49 kJ |
100 A |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
METI; PSE; QPL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
450 V |
30 A |
Tab/Blade |
993 J |
-40 °C (-40 °F) |
10 kA |
50 ms |
0.406 in (10.3 mm) |
450 V |
1.531 in (38.9 mm) |
CSA; UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.51 kJ |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
0.74 in (18.8 mm) |
UL |
105 °C (221 °F) |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
10 kA |
0.812 in (20.62 mm) |
1.623 in (41.23 mm) |
Fast |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
30 A |
End Cap |
||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1 kJ |
-40 °C (-40 °F) |
1 kA |
20 ms |
Bulk |
0.358 in (9.1 mm) |
0.15 in (3.8 mm) |
32 V |
Micro |
0.311 in (7.9 mm) |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
Tab/Blade |
2.679 kJ |
20 kA |
4 m |
Bulk |
0.406 in (10.31 mm) |
Midget |
1.5 in (38.1 mm) |
UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
30 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
36 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
375 A |
1 m |
Bulk |
0.709 in (18 mm) |
0.551 in (14 mm) |
36 V |
1.614 x 0.551 x 0.256 in (41 x 14 x 6.5 mm) |
0.256 in (6.5 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
-40 °C (-40 °F) |
0.906 in (23 mm) |
0.646 in (16.4 mm) |
32 V |
0.906 x 0.646 x 1.205 in (23 x 16.4 x 30.6 mm) |
1.205 in (30.6 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.07 kJ |
Tin |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
Bulk |
0.748 in (19 mm) |
0.197 in (5 mm) |
e3 |
0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm) |
0.52 in (13.2 mm) |
UL |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
15.5 KV |
30 A |
End Cap |
60 kA |
15NLE-30E |
3 in (76.2 mm) |
3 x 23.874 in (76.2 x 606.4 mm) |
23.874 in (606.4 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
32 V |
30 A |
Pin Wire |
3.717 kJ |
-55 °C (-67 °F) |
Tin |
300 A |
318 |
Bulk |
0.275 in (6.99 mm) |
e3 |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
End Cap |
2.679 kJ |
20 kA |
4 m |
2679 |
Bulk |
0.406 in (10.31 mm) |
0.406 x 2.5 in (10.31 x 63.5 mm) |
2.5 in (63.5 mm) |
CE, TUV, UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
Silver |
1 kA |
1130 |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e4 |
32 V |
1.85 mΩ |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
30 A |
End Cap |
3.792 kJ |
50 kA |
4 m |
Bulk |
0.406 in (10.31 mm) |
4.333 in (110.06 mm) |
CUL; TUV; UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.2 kJ |
-40 °C (-40 °F) |
1 kA |
Bulk |
0.748 in (19 mm) |
0.197 in (5 mm) |
20 ms |
0.681 in (17.3 mm) |
UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.6 kJ |
-40 °C (-40 °F) |
1 kA |
Bulk |
0.469 in (11.9 mm) |
0.15 in (3.8 mm) |
20 ms |
0.335 in (8.5 mm) |
85 °C (185 °F) |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
500 V |
500 V |
30 A |
Pin Wire |
280 J |
-55 °C (-67 °F) |
Tin |
30 kA |
10 s |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.275 in (6.985 mm) |
e3 |
500 V |
3AB |
1.288 in (32.72 mm) |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
3.9 kJ |
-40 °C (-40 °F) |
1 kA |
40 ms |
Bulk |
0.638 in (16.2 mm) |
0.256 in (6.5 mm) |
0.394 in (10 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
30 A |
Tab/Blade |
2.679 kJ |
20 kA |
4 m |
0.406 in (10.31 mm) |
Midget |
1.5 in (38.1 mm) |
UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
30 A |
Tab/Blade |
-55 °C (-67 °F) |
200 kA |
0.563 in (14.3 mm) |
1.874 in (47.6 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
30 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
Bulk |
0.571 in (14.5 mm) |
0.472 in (12 mm) |
0.571 x 0.472 x 0.63 in (14.5 x 12 x 16 mm) |
0.63 in (16 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
4.07 kJ |
-40 °C (-40 °F) |
Silver |
Rated Breaking Capacity at 32 VDC: 1000 A |
1.15 in (29.21 mm) |
0.348 in (8.85 mm) |
e4 |
1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm) |
0.85 in (21.59 mm) |
125 °C (257 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
300 V |
30 A |
Tab/Blade |
-55 °C (-67 °F) |
10 kA |
Rated Breaking Capacity at 300 VDC: 10000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE, UL |
125 °C (257 °F) |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
30 A |
End Cap |
21.6 kJ |
50 kA |
0.811 in (20.6 mm) |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CE; CSA; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
30 A |
End Cap |
0.25 in (6.35 mm) |
32 V |
7AG |
0.875 in (22.225 mm) |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
30 A |
Tab/Blade |
1.264 kJ |
Tin |
1 kA |
Bulk |
0.469 in (11.9 mm) |
0.15 in (3.8 mm) |
e3 |
0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm) |
0.339 in (8.6 mm) |
UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
30 A |
Pin Wire |
2.49 kJ |
-55 °C (-67 °F) |
Tin |
100 A |
2490 |
0.275 in (6.99 mm) |
e3 |
250 V |
3AB |
0.275 x 1.288 in (6.99 x 32.72 mm) |
1.288 in (32.72 mm) |
CE, PSE, UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
32 V |
32 V |
30 A |
Wire |
355 J |
-60 °C (-76 °F) |
Tin |
100 A |
10 s |
Rated Breaking Capacity at 32 VDC: 300 A |
355 |
Bulk |
0.133 in (3.38 mm) |
e3 |
32 V |
Pico |
0.133 x 0.31 in (3.38 x 7.87 mm) |
0.31 in (7.87 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
65 V |
65 V |
30 A |
End Cap |
-55 °C (-67 °F) |
1 kA |
4 h |
540 |
0.25 in (6.35 mm) |
Supplemental |
65 V |
2.3 mΩ |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
30 A |
End Cap |
7.531 kJ |
-55 °C (-67 °F) |
Nickel |
100 A |
388 |
Bulk |
0.25 in (6.35 mm) |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; KTL; PSE |
125 °C (257 °F) |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
30 A |
End Cap |
Silver |
594 |
e4 |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
30 A |
End Cap |
0.25 in (6.35 mm) |
32 V |
1.438 in (36.5125 mm) |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
25.8 KV |
30 A |
End Cap |
40 kA |
5 m |
3 in (76.2 mm) |
Striker |
3 x 24.625 in (76.2 x 625.48 mm) |
24.875 in (631.83 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
End Cap |
-55 °C (-67 °F) |
Nickel |
200 A |
4 h |
540 |
0.25 in (6.35 mm) |
Supplemental |
65 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE, UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
30 A |
Tab/Blade |
1.11 kJ |
-40 °C (-40 °F) |
Silver |
1 kA |
Bulk |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e4 |
0.429 x 0.15 x 0.331 in (10.9 x 3.8 x 8.4 mm) |
0.331 in (8.4 mm) |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
30 A |
-40 °C (-40 °F) |
0.906 in (23 mm) |
0.646 in (16.4 mm) |
32 V |
0.906 x 0.646 x 0.996 in (23 x 16.4 x 25.3 mm) |
0.996 in (25.3 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
30 A |
End Cap |
3.22 kJ |
-55 °C (-67 °F) |
Nickel |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
30 A |
Tab/Blade |
3.2 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
30 A |
Tab/Blade |
Blister |
||||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
12 V |
30 A |
Tab/Blade |
-40 °C (-40 °F) |
1 kA |
30 ms |
Bulk |
0.43 in (10.92 mm) |
0.15 in (3.81 mm) |
Mini |
0.345 in (8.76 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
125 V |
30 A |
End Cap |
10 kA |
2 m |
Bulk |
0.406 in (10.31 mm) |
125 V |
5AG |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.