32 A Fuses 38

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

C10G32

Eaton Corporation

Electric Fuse

Inline/Holder

400 V

400 V

32 A

End Cap

120 kA

C10

0.394 in (10 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

FWP-32A22F

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

500 V

32 A

End Cap

55 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Box

0.874 in (22.2 mm)

0.874 x 2.283 in (22.2 x 58 mm)

2.283 in (58 mm)

IEC; UL

32ET

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

350 V

32 A

Tab/Blade

32 J

200 kA

Rated Breaking Capacity at 690 VDC: 200000 A

Box

1.89 in (48 mm)

1.89 x 0.752 in (48 x 19.1 mm)

0.752 in (19.1 mm)

BS 88; CE

170M1312

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

32 A

Tab/Blade

40 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

NITD32

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

32 A

Tab/Blade

710 J

80 kA

Box

0.539 in (13.7 mm)

0.539 x 1.362 in (13.7 x 34.6 mm)

1.362 in (34.6 mm)

IEC

FWC-32A10F

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

400 V

32 A

End Cap

95 J

200 kA

Rated Breaking Capacity at 400 VDC: 50000 A

Box

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; UL

8020.5026.G

Schurter Ag

Electric Fuse

Inline/Holder

400 V

63 V

32 A

End Cap

8.75 kJ

-40 °C (-40 °F)

1.5 kA

Rated Breaking Capacity at 63 VDC: 20000 A

Bulk

0.25 in (6.35 mm)

10 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL; UL

85 °C (185 °F)

Time Lag

8020.5083

Schurter Ag

Electric Fuse

Inline/Holder

440 V

63 V

32 A

End Cap

4.75 kJ

-40 °C (-40 °F)

1.5 kA

4750

Bulk

0.25 in (6.35 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CUL, UL

85 °C (185 °F)

Very Fast

FR10GG40V32I

Mersen S A

Electric Fuse

Inline/Holder

400 V

250 V

32 A

End Cap

120 kA

Rated Breaking Capacity at 250 VDC: 100000 A

0.402 in (10.2 mm)

Indicator

0.406 x 1.496 in (10.3 x 38 mm)

1.496 in (38 mm)

CE

32NHG000B

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

32 A

Tab/Blade

1.8 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

32NHG000BI

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

32 A

Tab/Blade

1.8 kJ

120 kA

Box

1.929 in (49 mm)

0.827 in (21 mm)

NH000

Indicator

1.614 in (41 mm)

CE; DIN; IEC; VDE

SPXV032.LXM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

GPV

1.5 KV

0.394 x 3.346 in (10 x 85 mm)

3.333 in (84.65 mm)

CUL; TUV; UL

Fast

170M1412

Eaton Corporation

Electric Fuse

Inline/Holder

700 V

32 A

Tab/Blade

40 J

200 kA

Box

2.126 in (54 mm)

0.827 in (21 mm)

Indicator

2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm)

1.575 in (40 mm)

CE; CSA; DIN 43653; IEC; UL

170M2675

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

32 A

Tab/Blade

53 J

150 kA

1.929 in (49 mm)

1.181 in (30 mm)

Indicator

1.929 x 1.181 x 2.362 in (49 x 30 x 60 mm)

2.362 in (60 mm)

CE; DIN 43620; IEC; UL

32LET

Eaton Corporation

Electric Fuse

Inline/Holder

240 V

150 V

32 A

Tab/Blade

32 J

200 kA

Rated Breaking Capacity at 150 VDC: 200000 A

Box

0.697 in (17.7 mm)

0.697 x 1.031 in (17.7 x 26.2 mm)

1.031 in (26.2 mm)

CE; IEC; UL

C22G32

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

690 V

32 A

End Cap

80 kA

C22

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

ESD32

Eaton Corporation

Electric Fuse

Inline/Holder

550 V

250 V

32 A

Tab/Blade

710 J

80 kA

Rated Breaking Capacity at 250 VDC: 80000 A

Box

0.543 in (13.8 mm)

0.543 x 1.398 in (13.8 x 35.5 mm)

1.398 in (35.5 mm)

IEC

TIA32

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

460 V

32 A

Tab/Blade

1.08 kJ

80 kA

Bulk

2.22 in (56.4 mm)

2.22 x 0.874 in (56.4 x 22.2 mm)

0.874 in (22.2 mm)

BS; IEC

NH00CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

CY14X51G32

Littelfuse

Electric Fuse

Inline/Holder

500 V

32 A

End Cap

120 kA

0.551 in (14 mm)

500 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Fast

LA70QS32-22FI

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

32 A

End Cap

270 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

CSA; UL

Very Fast

NH00M32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

SPXI032.LXM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

4.333 in (110.06 mm)

CUL; TUV; UL

CY10X38M32

Littelfuse

Electric Fuse

Inline/Holder

400 V

32 A

End Cap

120 kA

0.394 in (10 mm)

400 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

NH0G32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

CY22X58G32

Littelfuse

Electric Fuse

Inline/Holder

690 V

32 A

End Cap

80 kA

0.866 in (22 mm)

690 V

0.866 x 2.283 in (22 x 58 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

Fast

CY10X38G32

Littelfuse

Electric Fuse

Inline/Holder

500 V

32 A

End Cap

120 kA

0.394 in (10 mm)

400 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Fast

LA70QS32-14FI

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

32 A

End Cap

1.5 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CSA; UL

Very Fast

NH1CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

LA70QS32-14F

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

32 A

End Cap

1.5 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.551 in (14 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

CSA; UL

Very Fast

SPXI032.LXBM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

4.49 in (114.05 mm)

TUV; UL

SPXV032.TXM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

GPV

1.5 KV

0.394 x 3.346 in (10 x 85 mm)

3.333 in (84.65 mm)

CUL; TUV; UL

Fast

SPXI032.TXBM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

4.49 in (114.05 mm)

TUV; UL

SPXI032.TXM

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

32 A

End Cap

4.35 kJ

50 kA

6 m

Bulk

0.406 in (10.31 mm)

4.333 in (110.06 mm)

CUL; TUV; UL

LA70QS32-22F

Littelfuse

Electric Fuse

Inline/Holder

690 V

700 V

32 A

End Cap

270 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

CSA; UL

Very Fast

NH00CM32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

CY14X51M32

Littelfuse

Electric Fuse

Inline/Holder

500 V

32 A

End Cap

120 kA

0.551 in (14 mm)

500 V

0.551 x 2.008 in (14 x 51 mm)

0.551 x 2.008 in (14 x 51 mm)

2.008 in (51 mm)

IEC

Time Lag

CY22X58M32

Littelfuse

Electric Fuse

Inline/Holder

690 V

32 A

End Cap

80 kA

0.866 in (22 mm)

500 V

0.866 x 2.283 in (22 x 58 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

IEC

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.