4 A Fuses 1,332

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0253004.NR

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

50 A

4 ms

Rated Breaking Capacity at 125 VDC: 300 A

Tape And Reel

0.11 in (2.8 mm)

125 V

Pico

0.28 in (7.11 mm)

CCC; CSA; CUL; PSE; TUV; QPL; UL

125 °C (257 °F)

Very Fast

251004

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Tin/Lead with Nickel barrier

50 A

1 s

Rated Breaking Capacity at 125 VDC: 300 A, Pre Arcing Time: Open within 1 s at 200% Rated Current

2.45

0.11 in (2.8 mm)

e0

125 V

Pico

0.28 in (7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; QPL; UL

125 °C (257 °F)

Very Fast

0471004.NRT1

Littelfuse

Electric Fuse

4 A

10.6 J

-55 °C (-67 °F)

50 A

4 h

Tape And Reel

0.095 in (2.41 mm)

125 V

Pico

0.095 x 0.28 in (2.41 x 7.11 mm)

0.28 in (7.11 mm)

CSA, PSE, UL

125 °C (257 °F)

Time Lag

238005

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

311 J

238

0.207 in (5.25 mm)

0.207 x 0.886 in (5.25 x 22.5 mm)

0.886 in (22.5 mm)

CSA; MITI; UL

Time Lag

0239004.MRET1P

Littelfuse

Electric Fuse

Through Hole Mount

125 V

4 A

Pin Wire

270.703 J

-55 °C (-67 °F)

Tin

10 kA

4 h

270.7

Tape And Reel

0.228 in (5.8 mm)

Supplemental

e3

125 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

FLQ4

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

4 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Slow

0263004.HAT1HF

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

3.08 J

-55 °C (-67 °F)

Pure Tin

50 A

Ammo Pack

0.155 in (3.94 mm)

0.155 x 0.28 in (3.94 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; UL

125 °C (257 °F)

Very Fast

0263004.VAT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

3.08 J

-55 °C (-67 °F)

Pure Tin

50 A

Ammo Pack

0.155 in (3.94 mm)

0.155 x 0.28 in (3.94 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; UL

125 °C (257 °F)

Very Fast

0234004.XE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

10.7 J

-55 °C (-67 °F)

Tin Lead

200 A

Pre-Arcing Time: Open within 0.4 s, at 200% Rated Current

0.228 in (5.8 mm)

e0

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Medium

0232004.XE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

38.75 J

100 A

232

0.228 in (5.8 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

KTL; METI; PSE

Medium

0263004.MXT1HF

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

3.08 J

-55 °C (-67 °F)

Pure Tin

50 A

0263

Bulk

0.155 in (3.94 mm)

0.155 x 0.28 in (3.94 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; UL

125 °C (257 °F)

Very Fast

0263004WRT1L

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

3.08 J

-55 °C (-67 °F)

Tin

50 A

Tape And Reel

0.145 in (3.68 mm)

e3

0.145 x 0.3 in (3.68 x 7.62 mm)

0.3 in (7.62 mm)

CSA; UL

125 °C (257 °F)

Very Fast

997004

Littelfuse

Electric Fuse

Inline/Holder

58 V

4 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

0663004

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

80 J

35 A

663

0.335 in (8.5 mm)

0.335 x 0.333 in (8.5 x 8.45 mm)

0.333 in (8.45 mm)

CSA; IEC; SEMKO; UL; VDE

Time Lag

0274004.V

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

-55 °C (-67 °F)

Tin

100 kA

4 h

Bulk

0.25 in (6.35 mm)

e3

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA, UL

125 °C (257 °F)

Very Fast

1621400100

Littelfuse

Electric Fuse

Inline/Holder

32 V

4 A

Tab/Blade

19 J

-40 °C (-40 °F)

1 kA

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

20 ms

0.681 in (17.3 mm)

UL

85 °C (185 °F)

Very Fast

0215004.MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

46.96 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

R271004

Littelfuse

Electric Fuse

Surface Mount

60 V

60 V

4 A

End Cap

2.35 J

-55 °C (-67 °F)

50 A

1 s

Rated Breaking Capacity at 60 VDC: 300 A, Pre Arcing Time: Open within 1 s at 200% Rated Current

Tape And Reel

0.08 in (2.032 mm)

Nano

0.225 in (5.715 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0251004.PRT1L

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Matte Tin

50 A

4 ms

Pre-Arcing Time: Open within 4 ms at 1000% Rated Current

2.45

Tape And Reel

0.11 in (2.8 mm)

Supplemental

e3

125 V

Pico

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CCC; CSA; CUL; PSE; TUV; UL

125 °C (257 °F)

Very Fast

80814000075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

4 A

Pin Wire

544.5 mJ

-65 °C (-85 °F)

Tin

200 A

10 s

Pre Arcing Time: Open within 10 s at 200% Rated Current

0.54

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

CUL; PSE; UL

125 °C (257 °F)

Fast

213004XP

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

202 J

-55 °C (-67 °F)

Matte Tin

100 A

213

Bulk; Tape And Reel

0.205 in (5.2 mm)

e3

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CCC; CE; CSA; IEC; PSE; SEMKO; UL

125 °C (257 °F)

Time Lag

0438004.WRGT

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

4 A

Wraparound

739 mJ

-55 °C (-67 °F)

50 A

5 s

Tape And Reel

0.062 in (1.582 mm)

0.033 in (0.83 mm)

32 V

16.4 mΩ

0603

0.02 in (0.508 mm)

CSA; CUL; UL

150 °C (302 °F)

Fast

0251004.VXL

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Matte Tin

50 A

Rated Breaking Capacity at 125 VDC: 300 A

Bulk

0.11 in (2.8 mm)

e3

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; QPL; TUV; UL

125 °C (257 °F)

Very Fast

0672004.

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

8.86 J

Tin Lead

50 A

672

0.154 in (3.9 mm)

e0

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

160004.MR

Littelfuse

Electric Fuse

Surface Mount

250 V

4 A

Wraparound

68.1 J

-55 °C (-67 °F)

Silver

50 A

4 h

122.5

Tape And Reel

0.398 in (10.1 mm)

0.123 in (3.12 mm)

e4

250 V

Nano

0.398 x 0.123 x 0.123 in (10.1 x 3.12 x 3.12 mm)

0.123 in (3.12 mm)

UL

125 °C (257 °F)

0407004.WR

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

4 A

Wraparound

4.18 J

-55 °C (-67 °F)

Matte Tin Over Nickel

50 A

2 ms

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

32 V

25 mΩ

1206

0.033 in (0.835 mm)

UL

150 °C (302 °F)

Time Lag

0230004.MXF16OP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

148 J

-55 °C (-67 °F)

Matte Tin

400 A

Bulk

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

0454004

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

4 A

End Cap

34.4 J

-55 °C (-67 °F)

Silver

50 A

Rated Breaking Capacity at 125 VDC: 50 A, Joule Integral Nom at 125 VDC: 34.4

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CSA; UL

125 °C (257 °F)

Slow

0253004.NXT3L

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Pure Tin

50 A

Rated Breaking Capacity at 125 VDC: 300 A

Bulk

0.11 in (2.8 mm)

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; QPL; TUV; UL

125 °C (257 °F)

Very Fast

0253004.NRL

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Tin

50 A

0253

Rated Breaking Capacity at 125 VDC: 300 A

Tape And Reel

0.103 in (2.61 mm)

e3

0.103 x 0.28 in (2.61 x 7.11 mm)

0.28 in (7.11 mm)

CCC; CSA; PSE; QPL; TUV; UL

125 °C (257 °F)

Very Fast

224004M

Littelfuse

Electric Fuse

Through Hole Mount

125 V

4 A

Pin Wire

9.4 J

Tin Lead

10 kA

224

Bulk

0.177 in (4.5 mm)

e0

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

0218004.HXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

69.1 J

-55 °C (-67 °F)

Tin

40 A

Bulk

0.228 in (5.8 mm)

e3

0.228 x 0.886 in (5.8 x 22.5 mm)

0.886 in (22.5 mm)

CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 °C (257 °F)

Time Lag

0253004.MRT3L

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Tin

50 A

0253

Rated Breaking Capacity at 125 VDC: 300 A

Tape And Reel

0.103 in (2.61 mm)

e3

0.103 x 0.28 in (2.61 x 7.11 mm)

0.28 in (7.11 mm)

CCC; CSA; PSE; QPL; TUV; UL

125 °C (257 °F)

Very Fast

0251004.HXL

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Tin

50 A

4 ms

Pre-Arcing Time: Open within 4 ms at 1000% Rated Current

Bulk

0.11 in (2.8 mm)

e3

Pico

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CCC; CSA; CUL; PSE; TUV; UL

125 °C (257 °F)

Very Fast

235004

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

17.138 J

-55 °C (-67 °F)

Nickel

10 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

0253004.MRT1L

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Pure Tin

50 A

Rated Breaking Capacity at 125 VDC: 300 A

2.45

Tape And Reel

0.11 in (2.8 mm)

Supplemental

125 V

Pico

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; TUV; UL

125 °C (257 °F)

Very Fast

0314004.VXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

4 A

End Cap

10.4 J

-55 °C (-67 °F)

Nickel

750 A

Rated Breaking Capacity at 125 VDC: 10000 A

10.4

Bulk

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

040014000075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

133.4 J

-40 °C (-40 °F)

Tin

130 A

20 ms

Bulk

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

TE5

0.315 in (8 mm)

CQC; CUL; KTL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

L25S4

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 250 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Fast

0253004.PRT3

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

2.45 J

-55 °C (-67 °F)

Pure Tin

50 A

4 ms

Pre-Arcing Time: Open within 4 ms at 1000% Rated Current

Tape And Reel

0.103 in (2.61 mm)

Pico

0.103 x 0.28 in (2.61 x 7.11 mm)

0.28 in (7.11 mm)

CCC; CSA; CUL; PSE; QPL; TUV; UL

125 °C (257 °F)

Very Fast

BLN4

Littelfuse

Electric Fuse

Inline/Holder

250 V

4 A

End Cap

10 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

481004

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

4 A

End Cap

Tin/Lead

481

e0

Alarm

KLK4

Littelfuse

Electric Fuse

Inline/Holder

600 V

4 A

End Cap

100 kA

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

0230004.ERT2P

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Pin Wire

148 J

-55 °C (-67 °F)

Matte Tin

400 A

Tape And Reel

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

239004.P

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

270.703 J

-55 °C (-67 °F)

Matte Tin

10 kA

Bulk; Tape And Reel

0.787 in (20 mm)

e3

0.787 x 0.205 in (20 x 5.2 mm)

0.205 in (5.2 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0235004.HXP

Littelfuse

Electric Fuse

Inline/Holder

125 V

4 A

End Cap

17.14 J

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.197 in (5 mm)

125 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

36914000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

4 A

Pin Wire

126.4 J

-40 °C (-40 °F)

Tin

50 A

20 s

100

Bulk

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

300 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

37214000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Pin Wire

95 J

-40 °C (-40 °F)

Matte Tin

40 A

Bulk

0.335 in (8.5 mm)

e3

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; KTL; PSE; SEMKO; UL; VDE

85 °C (185 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.