425 A Fuses 8

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

157.5701.6421

Littelfuse

Electric Fuse

Inline/Holder

48 V

425 A

Tab/Blade

-40 °C (-40 °F)

2.55 kA

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

3998425.ZXM10

Littelfuse

Electric Fuse

Surface Mount

80 V

425 A

Wraparound

690.2 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

157.5700.6421

Littelfuse

Electric Fuse

Inline/Holder

48 V

425 A

Tab/Blade

-40 °C (-40 °F)

2.55 kA

200 ms

Bulk

3.228 in (82 mm)

0.787 in (20 mm)

0.039 in (1 mm)

125 °C (257 °F)

0581425

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

425 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

48 V

1.535 x 0.683 in (39 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fast

157.5917.6421

Littelfuse

Electric Fuse

Inline/Holder

48 V

425 A

Tab/Blade

-40 °C (-40 °F)

2.55 kA

200 ms

Bulk

1.26 in (32 mm)

0.866 in (22 mm)

48 V

1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm)

0.413 in (10.5 mm)

CUL; UL

125 °C (257 °F)

NH3G425

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

425 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

3298425.ZXM10

Littelfuse

Electric Fuse

Panel Mount

32 V

425 A

Wraparound

602.77 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

Time Delay

581425

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

425 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.