450 A Fuses 242

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

PSR031FL0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Threaded

22.457 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.969 in (50 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

PSR071FL0450Z

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

450 A

Threaded

55.915 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.913 in (74 mm)

2.028 in (51.5 mm)

Indicator

3.402 in (86.4 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

LA070URD30LI0450

Littelfuse

Electric Fuse

Inline/Holder

700 V

450 A

Tab/Blade

26 J

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

450-24R-2C-5.5XS

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

450 A

End Cap

1.95 kA

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 17.875 in (162.05 x 454.03 mm)

17.875 in (454.03 mm)

Medium

RLS450

Littelfuse

Electric Fuse

Inline/Holder

600 V

450 A

Tab/Blade

10 kA

3.094 in (78.6 mm)

13.374 in (339.7 mm)

CE; CSA; UL

PSR030US0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Tab/Blade

23.133 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.878 in (47.7 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

0298450.UXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

450 A

Tab/Blade

1.05 MJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

450-24R-2C-5.5W

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

450 A

End Cap

1.95 kA

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

LA130URD71TTI0450

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

450 A

End Cap

47 J

100 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

450E-2C-2.75L

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

End Cap

80 kA

450E-2C-2.75

6.378 in (162 mm)

6.378 x 10.874 in (162 x 276.2 mm)

10.874 in (276.2 mm)

0298450.TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

450 A

Tab/Blade

-40 °C (-40 °F)

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

450-24R-2C-2.75W

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

End Cap

1.95 kA

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

450E2C2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

End Cap

80 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 10.875 in (162.05 x 276.23 mm)

10.874 in (276.2 mm)

Medium

LCU450ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

450 A

End Cap

80 kA

LCU

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 17.875 in (162.05 x 454.03 mm)

17.875 in (454.03 mm)

Medium

RLN450

Littelfuse

Electric Fuse

Inline/Holder

250 V

450 A

Tab/Blade

10 kA

2.594 in (65.9 mm)

10.374 in (263.5 mm)

CE; CSA; UL

0JLS450.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

450 A

Tab/Blade

200 kA

Bulk

2.5 in (63.5 mm)

J

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE; CSA; QPL; UL

Fast

PSR032FL0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Threaded

15.535 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

2.008 in (51 mm)

Indicator

3.736 in (94.9 mm)

CCC; CUL; UL

125 °C (257 °F)

Fast

450-24R-2C-8.25W

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

450 A

End Cap

1.91 kA

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

PSR073UL0450X

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

1 KV

450 A

Tab/Blade

29.834 kJ

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 1000 VDC: 150000 A

Bulk

2.921 in (74.2 mm)

2.894 in (73.5 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

SPFJ450

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 KV

450 A

Tab/Blade

565.333 kJ

200 kA

14 m

Rated Breaking Capacity at 1000 VDC: 20000 A

2.5 in (63.5 mm)

Midget

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CE; IEC; UL; VDE

PSR030FS0450Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

450 A

Threaded

23.133 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

1.969 in (50 mm)

1.693 in (43 mm)

Indicator

3.067 in (77.9 mm)

CUL; UL

125 °C (257 °F)

Fast

LA130URD72TTI0450

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

450 A

End Cap

44 J

100 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 2.854 in (60 x 60 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

JLLS450.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.063 in (52.4 mm)

600 V

1.764 in (44.8 mm)

CE; CSA; UL

Fast

450-24R-2C-5.5XW

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

450 A

End Cap

1.95 kA

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 17.875 in (162.05 x 454.03 mm)

17.875 in (454.03 mm)

Medium

KLH450

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

450 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

2 in (50.8 mm)

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

0898450.U-2M8

Littelfuse

Electric Fuse

Inline/Holder

70 V

450 A

Tab/Blade

1.224 MJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

LA070URD32LI0450

Littelfuse

Electric Fuse

Inline/Holder

700 V

450 A

Tab/Blade

22 J

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

0998450.UX-NH

Littelfuse

Electric Fuse

Inline/Holder

70 V

450 A

Tab/Blade

1.224 MJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

450-24R-2B-2.75

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

Tab/Blade

1.95 kA

Rated Breaking Capacity=1950A-80000A

7.4 in (187.96 mm)

Indicator

7.4 x 13 in (187.96 x 330.2 mm)

13 in (330.2 mm)

Medium

LA130URD72LI0450

Littelfuse

Electric Fuse

Inline/Holder

1.3 KV

450 A

Tab/Blade

44 J

100 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 2.854 in (60 x 60 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

LCK24RW

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

End Cap

1.95 kA

LCK

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

LCY450ES

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

450 A

End Cap

80 kA

LCY

Hermitically Sealed Part Number

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

LCK24R

Littelfuse

Electric Fuse

Inline/Holder

2.75 KV

450 A

End Cap

1.95 kA

LCK

Rated Breaking Capacity=1950A-80000A

6.38 in (162.05 mm)

6.38 x 10.875 in (162.05 x 276.23 mm)

10.875 in (276.23 mm)

Medium

0898450.U-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

450 A

Tab/Blade

1.224 MJ

-40 °C (-40 °F)

2.5 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0298450.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

450 A

Tab/Blade

1.05 MJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

0998450.UX-2M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

450 A

Tab/Blade

1.224 MJ

-40 °C (-40 °F)

Tin

2.5 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

e3

70 V

Mega

0.39 in (9.9 mm)

ISO

125 °C (257 °F)

LA070URD30KI0450

Littelfuse

Electric Fuse

Inline/Holder

700 V

450 A

Tab/Blade

26 J

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

0298450.ZXB

Littelfuse

Electric Fuse

Inline/Holder

32 V

450 A

Tab/Blade

1.05 MJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

Mega

0.421 in (10.7 mm)

125 °C (257 °F)

Time Delay

LA15QS450-4IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

450 A

Tab/Blade

50 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.13 in (28.7 mm)

1.13 x 1.161 in (28.7 x 29.5 mm)

1.161 in (29.5 mm)

UL

Very Fast

JLLN450P

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

3.063 in (77.8 mm)

CE; CSA; CUL; UL

Fast

EV1K450

Littelfuse

Electric Fuse

Inline/Holder

1 KV

450 A

Tab/Blade

-40 °C (-40 °F)

30 kA

Bulk

2 in (50.8 mm)

2.844 in (72.24 mm)

125 °C (257 °F)

EV1K450.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

1 KV

450 A

Tab/Blade

-40 °C (-40 °F)

30 kA

Bulk

2 in (50.8 mm)

2.844 in (72.24 mm)

125 °C (257 °F)

0JTD450.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

Indicator

3.752 in (95.3 mm)

CSA; UL

Time Delay

LA070URD32KI0450

Littelfuse

Electric Fuse

Inline/Holder

700 V

450 A

Tab/Blade

22 J

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LLSRK4.50ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

FLSR450ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

Indicator

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; QPL; UL

Time Delay

LA50QS450-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

450 A

Tab/Blade

130 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

2 in (50.8 mm)

500 V

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

KLSR450

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

450 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

13.374 in (339.7 mm)

CSA; UL

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.