6 A Fuses 440

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

SPXI006.L

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

6 A

End Cap

49 J

30 kA

4 m

Bulk

0.406 in (10.31 mm)

1.5 KV

0.406 x 4.354 in (10.31 x 110.6 mm)

4.333 in (110.06 mm)

CUL; TUV; UL

0407006.WRA

Littelfuse

Electric Fuse

Surface Mount

24 V

6 A

Wraparound

15.56 J

-55 °C (-67 °F)

60 A

50 ms

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

1206

0.033 in (0.835 mm)

AEC-Q200; CUL; UL

150 °C (302 °F)

594006

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

6 A

End Cap

Nickel

594

224006P

Littelfuse

Electric Fuse

Through Hole Mount

125 V

6 A

Pin Wire

22.1 J

Matte Tin

500 A

224

Bulk; Tape And Reel

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; UL

Fast

C52564-000

Littelfuse

Electric Fuse

Surface Mount

24 V

6 A

Wraparound

8.5 J

60 A

UL

125 °C (257 °F)

Slow

0233006.

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

131.456 J

-55 °C (-67 °F)

Nickel

10 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Medium

KLKD006.

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

100 kA

Rated Breaking Capacity at 600 VDC: 10000 A

0.406 in (10.31 mm)

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

IDSR006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

FLNR6ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

200 kA

0.563 in (14.3 mm)

Indicator

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

225006M

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

22.1 J

10 kA

225

Bulk

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

0874006.MRET1P

Littelfuse

Electric Fuse

6 A

Pin Wire

-55 °C (-67 °F)

50 A

4 h

23.08

Tape And Reel

0.142 in (3.6 mm)

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.394 in (10 mm)

UL

125 °C (257 °F)

Fast

0674006.

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6 A

Pin Wire

18 J

Tin Lead

50 A

674

0.154 in (3.9 mm)

e0

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

SOO006

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

10 kA

UL

Time Delay

0324006.MX24P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6 A

Pin Wire

45 J

-55 °C (-67 °F)

Tin

750 A

45

0.275 in (6.99 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

SPFI006.T

Littelfuse

Electric Fuse

Inline/Holder

1 KV

6 A

End Cap

80 J

20 kA

4 m

80

Bulk

0.406 in (10.31 mm)

0.406 x 2.5 in (10.31 x 63.5 mm)

2.5 in (63.5 mm)

CE, TUV, UL

0388006.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

6 A

End Cap

-55 °C (-67 °F)

Tin

100 A

Bulk

0.25 in (6.35 mm)

e3

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; KTL; PSE

125 °C (257 °F)

KLKD006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 1.5 in (38.1 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL; VDE

125 °C (257 °F)

Fast

JLLS006

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 1.5 in (14.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

0229006.HXSP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

6 A

End Cap

380 J

-55 °C (-67 °F)

Tin

400 A

4 h

380

Bulk

0.177 in (4.5 mm)

e3

125 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

FLM006

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

6 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

250 V

0.394 x 1.496 in (10 x 38 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

AGC6CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

0224006.DRT1P

Littelfuse

Electric Fuse

6 A

Pin Wire

-55 °C (-67 °F)

Tin

500 A

4 h

22.1

Tape And Reel

0.189 in (4.8 mm)

e3

125 V

2AG

0.189 x 0.587 in (4.8 x 14.9 mm)

0.587 in (14.9 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

0318006.VXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6 A

Pin Wire

118 J

-55 °C (-67 °F)

Matte Tin

200 A

318

Bulk

0.275 in (6.99 mm)

e3

0.275 x 1.288 in (6.99 x 32.72 mm)

1.288 in (32.72 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

0230006.DRT2P

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

6 A

Pin Wire

380 J

-55 °C (-67 °F)

Matte Tin

400 A

Tape And Reel

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

NLS006

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

50 kA

Rated Breaking Capacity at 600 VDC; 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

CSA; UL

CY10X38M6

Littelfuse

Electric Fuse

Inline/Holder

500 V

6 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

672006MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6 A

Pin Wire

18 J

50 A

5 s

Bulk

0.154 in (3.9 mm)

0.142 x 0.394 in (3.6 x 10 mm)

0.433 in (11 mm)

CSA; UL

Fast

0JTD006.TXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.811 in (20.6 mm)

Indicator

2.252 in (57.2 mm)

CSA; UL

Time Delay

230006M

Littelfuse

Electric Fuse

Through Hole Mount

125 V

6 A

Pin Wire

380 J

-55 °C (-67 °F)

Tin Lead

400 A

230

Bulk

0.185 in (4.7 mm)

e0

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; METI; PSE; UL

125 °C (257 °F)

Slow

0230006.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

6 A

Pin Wire

380 J

-55 °C (-67 °F)

Matte Tin

400 A

Bulk

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

224006M

Littelfuse

Electric Fuse

Through Hole Mount

125 V

6 A

Pin Wire

22.1 J

Tin Lead

10 kA

224

Bulk

0.177 in (4.5 mm)

e0

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

0SPF006.TXS

Littelfuse

Electric Fuse

Inline/Holder

1 KV

6 A

End Cap

80 J

Silver

20 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

FLSR006.T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.815 in (20.7 mm)

5 in (127 mm)

CSA; UL

Time Delay

SPXI006.T

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

6 A

End Cap

49 J

Nickel

30 kA

4 m

Bulk

0.406 in (10.31 mm)

1.5 KV

0.406 x 4.354 in (10.31 x 110.6 mm)

4.333 in (110.06 mm)

CUL; TUV; UL

197-1600-000

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

96 J

-25 °C (-13 °F)

10 kA

Bulk

0.205 in (5.2 mm)

120 s

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

TLS006V

Littelfuse

Electric Fuse

Inline/Holder

170 V

6 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

0235006.MXBP

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

47.325 J

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.197 in (5 mm)

125 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

0311006.H

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

Normal

SPXV006.LXS

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

6 A

End Cap

49 J

Silver

30 kA

4 m

Bulk

0.406 in (10.31 mm)

e4

3.333 in (84.65 mm)

CE; CUL; IEC; UL

Fast

225006DRT1

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

22.1 J

10 kA

225

Tape And Reel

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; PSE; UL

Fast

236006

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6 A

Pin Wire

48.6 J

236

0.207 in (5.25 mm)

0.207 x 0.886 in (5.25 x 22.5 mm)

0.886 in (22.5 mm)

CSA; UL

Fast

KLKD006.HXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

6 A

End Cap

35 mJ

-55 °C (-67 °F)

100 kA

4 m

0.406 in (10.31 mm)

600 V

0.394 x 1.496 in (10 x 38 mm)

1.5 x 0.406 x 1.5 in (38.1 x 10.31 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; IEC; UL

125 °C (257 °F)

Fast

0673006DRT4

Littelfuse

Electric Fuse

6 A

Pin Wire

50 A

4 h

77.2

0.154 in (3.9 mm)

250 V

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA, UL

Time Lag

SFE6BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

0.25 in (6.35 mm)

32 V

0.75 in (19.05 mm)

0230006.DAT1OP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

6 A

Pin Wire

380 J

-55 °C (-67 °F)

Matte Tin

400 A

Tape And Reel

0.185 in (4.7 mm)

e3

0.185 x 0.57 in (4.7 x 14.48 mm)

0.57 in (14.48 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Time Lag

1206SFS600F/24-2

Littelfuse

Electric Fuse

Surface Mount

24 V

6 A

Wraparound

8.5 J

-55 °C (-67 °F)

60 A

2 ms

Pre Arcing Time: Blow within 0.002 s at 800% Rated Current

Tape And Reel, Plastic,7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

24 V

1206

0.038 in (0.97 mm)

UL

125 °C (257 °F)

Slow

AGW6CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

6 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

0TLS006.TXLS

Littelfuse

Electric Fuse

Inline/Holder

170 V

6 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.