6.5 A Fuses 13

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LLNRK6.50

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

6.5 A

End Cap

20 kA

Rated Breaking Capacity at 125 VDC: 20000

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

Time Delay

067406.5MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.6 J

Tin Lead

50 A

4 h

21.6

Bulk

0.154 in (3.9 mm)

e0

250 V

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

67206.5DRT4

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

50 A

5 s

Tape And Reel

0.154 in (3.9 mm)

0.142 x 0.394 in (3.6 x 10 mm)

0.433 in (11 mm)

CSA; UL

Fast

67206.5MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

50 A

5 s

Bulk

0.154 in (3.9 mm)

0.142 x 0.394 in (3.6 x 10 mm)

0.433 in (11 mm)

CSA; UL

Fast

67206.5

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

50 A

5 s

0.154 in (3.9 mm)

0.142 x 0.394 in (3.6 x 10 mm)

0.433 in (11 mm)

CSA; UL

Fast

067406.5DRT4

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.6 J

Tin Lead

50 A

4 h

21.6

Tape And Reel

0.154 in (3.9 mm)

e0

250 V

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

067206.5DRT4

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

Tin Lead

50 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

21.9

Tape And Reel

0.154 in (3.9 mm)

e0

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

067206.5MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

Tin Lead

50 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current

21.9

Bulk

0.154 in (3.9 mm)

e0

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

LLSRK6.50

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

6.5 A

End Cap

20 kA

Rated Breaking Capacity at 300 VDC: 20000

0.811 in (20.6 mm)

0.811 x 5 in (20.6 x 127 mm)

5 in (127 mm)

Time Delay

087406.5MRET1P

Littelfuse

Electric Fuse

6.5 A

Pin Wire

-55 °C (-67 °F)

50 A

4 h

35.24

Tape And Reel

0.142 in (3.6 mm)

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.394 in (10 mm)

UL

125 °C (257 °F)

Fast

067206.5

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.9 J

Tin Lead

50 A

672

0.154 in (3.9 mm)

e0

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

067406.5

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

21.6 J

Tin Lead

50 A

674

0.154 in (3.9 mm)

e0

0.154 x 0.433 in (3.9 x 11 mm)

0.433 in (11 mm)

CSA; UL

Fast

087406.5MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.5 A

Pin Wire

35.24 J

-55 °C (-67 °F)

Tin

50 A

4 h

35.24

Bulk

0.142 in (3.6 mm)

e3

250 V

0.142 x 0.394 in (3.6 x 10 mm)

0.394 in (10 mm)

UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.