600 A Fuses 119

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KLPC600

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

CNN600

Littelfuse

Electric Fuse

Inline/Holder

125 V

48 V

600 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Very Fast

LDC0600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

KLW600

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

600 A

Tab/Blade

100 kA

KLW

Rated Breaking Capacity at 100 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

Fast

RLN600

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 A

Tab/Blade

10 kA

2.594 in (65.9 mm)

10.374 in (263.5 mm)

CE; CSA; UL

600-32R-3C-5.5W

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

600 A

End Cap

2.6 kA

Part Number With Hookeye Attachment

9.75 in (247.65 mm)

9.75 x 15.875 in (247.65 x 403.23 mm)

15.875 in (403.23 mm)

Medium

600-32R-2C-5.5W

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

600 A

End Cap

2.6 kA

Part Number With Hookeye Attachment

6.38 in (162.05 mm)

6.38 x 15.875 in (162.05 x 403.23 mm)

15.875 in (403.23 mm)

Medium

NLN600

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

600 A

Tab/Blade

4.846 MJ

50 kA

2.594 in (65.9 mm)

2.594 x 5.87 in (65.9 x 149.1 mm)

10.374 in (263.5 mm)

CE; CSA; UL

LA15QS600-4IL

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

600 A

Tab/Blade

130 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Very Fast

KLC600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 A

Tab/Blade

-55 °C (-67 °F)

200 kA

2.5 in (63.5 mm)

2.5 x 2.843 in (63.5 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

125 °C (257 °F)

Very Fast

JLLN600.XXP

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.594 in (40.5 mm)

300 V

3.063 in (77.8 mm)

CE; CSA; CUL; UL

Fast

LA100P600-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

600 A

Tab/Blade

650 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

2.5 in (63.5 mm)

Indicator

2.5 x 3.469 in (63.5 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

LLSRK600

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

3.094 in (78.6 mm)

3.094 x 13.374 in (78.6 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

600-32R-2BI-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

600 A

Tab/Blade

2.65 kA

Rated Breaking Capacity=2650A-80000A

7.6 in (193.04 mm)

Indicator

7.6 x 18 in (193.04 x 457.2 mm)

18 in (457.2 mm)

Medium

600-32R-2B-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

600 A

Tab/Blade

2.65 kA

Rated Breaking Capacity=2650A-80000A

8.4 in (213.36 mm)

Indicator

8.4 x 18 in (213.36 x 457.2 mm)

18 in (457.2 mm)

Medium

L60S600.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 A

Tab/Blade

-55 °C (-67 °F)

200 kA

Box

2.079 in (52.8 mm)

2.874 in (73 mm)

CSA; UL

125 °C (257 °F)

Very Fast

FLNR600ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.594 in (65.9 mm)

Indicator

2.594 x 10.374 in (65.9 x 263.5 mm)

10.374 in (263.5 mm)

CSA; QPL; UL

Time Delay

0JTD600.XXID

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

600 A

Tab/Blade

1.97 MJ

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

600 V

Indicator

3.752 in (95.3 mm)

CSA; UL

Time Delay

L60S600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 A

Tab/Blade

-55 °C (-67 °F)

200 kA

2.079 in (52.8 mm)

2.079 x 2.874 in (52.8 x 73 mm)

2.874 in (73 mm)

CSA; UL

125 °C (257 °F)

Very Fast

L25S600

Littelfuse

Electric Fuse

Inline/Holder

250 V

200 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 200 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.594 in (38.1 x 40.5 mm)

1.594 in (40.5 mm)

CSA; UL

Fast

3298600.ZXM10

Littelfuse

Electric Fuse

Panel Mount

32 V

600 A

Wraparound

3.14 MJ

-40 °C (-40 °F)

2 kA

1.232 in (31.3 mm)

0.984 in (25 mm)

0.63 in (16 mm)

125 °C (257 °F)

Time Delay

LA15QS600-4

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

600 A

Tab/Blade

130 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Very Fast

IDSR600

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

600 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 20000 A

Bulk

3.043 in (77.3 mm)

3 x 13.374 in (76.2 x 339.7 mm)

13.374 in (339.7 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.