600 mA Fuses 249

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0312.600HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

600 mA

End Cap

880 mJ

-55 °C (-67 °F)

Tin

35 A

5 s

Tape And Reel

0.25 in (6.35 mm)

e3

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

LLNRK.600

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

KLDR.600T

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

600 mA

End Cap

200 kA

KLDR

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

238.600

Littelfuse

Electric Fuse

Through Hole Mount

250 V

600 mA

Pin Wire

2.48 J

238

0.207 in (5.25 mm)

0.207 x 0.886 in (5.25 x 22.5 mm)

0.886 in (22.5 mm)

CSA; UL

Time Lag

0272.600H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

600 mA

Pin Wire

41.1 mJ

-55 °C (-67 °F)

Tin

10 kA

4 h

Bulk

0.235 in (5.97 mm)

e3

125 V

Micro

0.235 x 0.287 in (5.97 x 7.3 mm)

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

FLQ.600T

Littelfuse

Electric Fuse

Inline/Holder

500 V

300 V

600 mA

End Cap

-55 °C (-67 °F)

10 kA

0.406 in (10.31 mm)

500 V

Midget

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA, UL

125 °C (257 °F)

Time Lag

FLNR.600

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

600 mA

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Bulk

0.563 in (14.3 mm)

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

0274.600V

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

600 mA

Pin Wire

-55 °C (-67 °F)

Tin

100 kA

4 h

Bulk

0.25 in (6.35 mm)

e3

125 V

Micro

0.25 x 0.35 in (6.35 x 8.89 mm)

0.35 in (8.89 mm)

CSA, UL

125 °C (257 °F)

Very Fast

0325.600VXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

600 mA

Pin Wire

-55 °C (-67 °F)

Tin

4 h

3.9

0.275 in (6.985 mm)

e3

250 V

3AB

0.275 x 1.288 in (6.985 x 32.72 mm)

1.288 in (32.72 mm)

CE, CSA, UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.