Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
240 V |
150 V |
63 A |
Tab/Blade |
180 J |
200 kA |
Rated Breaking Capacity at 150 VDC: 200000 A |
Box |
0.697 in (17.7 mm) |
0.697 x 1.031 in (17.7 x 26.2 mm) |
1.031 in (26.2 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
Box |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
63 A |
Tab/Blade |
6.3 kJ |
120 kA |
Box |
1.929 in (49 mm) |
0.827 in (21 mm) |
NH000 |
Indicator |
1.614 in (41 mm) |
CE; DIN; IEC; VDE |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
690 V |
63 A |
Tab/Blade |
215 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
Indicator |
2.126 x 0.827 x 1.378 in (54 x 21 x 35 mm) |
1.378 in (35 mm) |
CE; DIN 43620; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
63 A |
Tab/Blade |
135 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.89 in (48 mm) |
1.89 x 0.752 in (48 x 19.1 mm) |
0.752 in (19.1 mm) |
BS 88; CE |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
63 A |
End Cap |
26.5 kJ |
50 kA |
Bulk |
1.063 in (27 mm) |
DIII |
1.969 in (50 mm) |
DIN 49515; IEC60269 |
Fast |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
690 V |
63 A |
End Cap |
80 kA |
C22 |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.874 in (22.2 mm) |
Indicator |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
CE; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
63 A |
End Cap |
26.5 kJ |
50 kA |
Bulk |
1.063 in (27 mm) |
DIII |
1.969 in (50 mm) |
DIN 49515; IEC60269 |
Ultra Fast |
|||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
63 A |
Tab/Blade |
7 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.303 in (21 x 58.5 mm) |
2.303 in (58.5 mm) |
IEC |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
Tab/Blade |
215 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
Tab/Blade |
215 J |
200 kA |
Box |
2.126 in (54 mm) |
0.827 in (21 mm) |
Indicator |
2.126 x 0.827 x 1.575 in (54 x 21 x 40 mm) |
1.575 in (40 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
Tab/Blade |
170 J |
200 kA |
Box |
2.126 in (54 mm) |
1.181 in (30 mm) |
Indicator |
2.126 x 1.181 x 2.008 in (54 x 30 x 51 mm) |
2.008 in (51 mm) |
CE; CSA; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
63 A |
Tab/Blade |
6.7 kJ |
80 kA |
Box |
0.827 in (21 mm) |
0.827 x 2.126 in (21 x 54 mm) |
2.126 in (54 mm) |
IEC |
||||||||||||||||||
Siba |
Electric Fuse |
Inline/Holder |
690 V |
63 A |
Tab/Blade |
840 J |
200 kA |
Bulk |
2.165 in (55 mm) |
0.807 in (20.5 mm) |
Indicator |
1.535 in (39 mm) |
IEC, UL, VDE |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
63 A |
End Cap |
280 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.874 in (22.2 mm) |
0.874 x 2.283 in (22.2 x 58 mm) |
2.283 in (58 mm) |
CE; IEC; UL |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
690 V |
350 V |
63 A |
Tab/Blade |
171 J |
200 kA |
Rated Breaking Capacity at 690 VDC: 200000 A |
Box |
1.89 in (48 mm) |
1.89 x 0.752 in (48 x 19.1 mm) |
0.752 in (19.1 mm) |
BS 88; CE |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
24 KV |
24 KV |
63 A |
End Cap |
3.8 kJ |
50 kA |
3 in (76.2 mm) |
3 x 17.402 in (76.2 x 442 mm) |
17.402 in (442 mm) |
DIN 43625; IEC; VDE |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
500 V |
63 A |
Tab/Blade |
16 kJ |
120 kA |
Bulk |
1.945 in (49.4 mm) |
1.163 in (29.55 mm) |
NH00 |
Indicator |
1.882 in (47.8 mm) |
IEC |
||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
400 V |
63 A |
End Cap |
12.3 kJ |
50 kA |
Bulk |
0.591 in (15 mm) |
D02 |
0.591 x 1.417 in (15 x 36 mm) |
1.417 in (36 mm) |
DIN 49515; IEC60269 |
Time Delay |
|||||||||||||||||
|
Phoenix Contact |
Electric Fuse |
Inline/Holder |
400 V |
250 V |
63 A |
End Cap |
-60 °C (-76 °F) |
0.591 in (15 mm) |
400 V |
1.417 in (36 mm) |
85 °C (185 °F) |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
48 V |
63 A |
Tab/Blade |
2.5 kA |
1.535 in (39 mm) |
1.195 in (30.35 mm) |
48 V |
1.535 x 0.683 in (39 x 17.35 mm) |
0.683 in (17.35 mm) |
UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
63 A |
Tab/Blade |
1.5 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
63 A |
Tab/Blade |
210 mJ |
100 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 2.854 in (40 x 40 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
63 A |
End Cap |
80 kA |
DZ |
Rated Breaking Capacity at 500 VDC: 80000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 1.969 in (27 x 50 mm) |
1.969 in (50 mm) |
DIN; IEC; VDE |
Time Lag |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
63 A |
Threaded |
273 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
690 V |
700 V |
63 A |
End Cap |
1.85 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
0.866 in (22 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
CSA; UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
380 V |
250 V |
63 A |
End Cap |
50 kA |
D0Z1 |
Rated Breaking Capacity at 250 VDC: 50000 A |
0.591 in (15 mm) |
Indicator |
0.591 x 1.417 in (15 x 36 mm) |
1.417 in (36 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
63 A |
Threaded |
273 J |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
63 A |
Threaded |
176 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
48 V |
63 A |
Tab/Blade |
2.5 kA |
1.535 in (39 mm) |
1.195 in (30.35 mm) |
1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm) |
0.683 in (17.35 mm) |
UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
63 A |
Tab/Blade |
176 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
63 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.1 in (53.34 mm) |
1.181 in (30 mm) |
Indicator |
2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm) |
2.76 in (70.11 mm) |
VDE |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
63 A |
Tab/Blade |
-40 °C (-40 °F) |
378 A |
200 ms |
Bulk |
3.228 in (82 mm) |
0.787 in (20 mm) |
0.024 in (0.6 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
63 A |
Tab/Blade |
1.5 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
500 V |
63 A |
Pin Wire |
7 kJ |
-55 °C (-67 °F) |
Tin |
2 kA |
2 m |
Pre Arcing Time: Open within 120 s at 200% Rated Current |
Tray |
0.482 in (12.25 mm) |
e3 |
500 V |
0.394 x 1.26 in (10 x 32 mm) |
1.315 in (33.4 mm) |
CSA; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
690 V |
63 A |
End Cap |
80 kA |
0.866 in (22 mm) |
500 V |
0.866 x 2.283 in (22 x 58 mm) |
0.866 x 2.283 in (22 x 58 mm) |
2.283 in (58 mm) |
IEC |
Time Lag |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
63 A |
Tab/Blade |
176 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
63 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.02 in (51.3 mm) |
0.787 in (20 mm) |
Indicator |
2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm) |
2.126 in (54 mm) |
VDE |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
End Cap |
200 mJ |
200 kA |
Indicator |
UL |
Very Fast |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
63 A |
End Cap |
80 kA |
DZ |
Rated Breaking Capacity at 500 VDC: 80000 A |
1.063 in (27 mm) |
Indicator |
1.063 x 1.969 in (27 x 50 mm) |
1.969 in (50 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
63 A |
Tab/Blade |
1.5 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
GPV |
1.5 KV |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
440 V |
63 A |
Tab/Blade |
120 kA |
Rated Breaking Capacity at 440 VDC: 25000 A |
2.02 in (51.3 mm) |
0.787 in (20 mm) |
Indicator |
2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm) |
2.126 in (54 mm) |
VDE |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
63 A |
Tab/Blade |
200 mJ |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
63 A |
Tab/Blade |
-40 °C (-40 °F) |
378 A |
200 ms |
Bulk |
3.228 in (82 mm) |
0.787 in (20 mm) |
0.024 in (0.6 mm) |
125 °C (257 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
63 A |
Tab/Blade |
-40 °C (-40 °F) |
378 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
63 A |
Tab/Blade |
1.5 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.008 in (51 mm) |
NH |
2.008 in (51 mm) |
UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
63 A |
Tab/Blade |
-40 °C (-40 °F) |
378 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.