7.5 A Fuses 168

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

CCMR07.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7.5 A

End Cap

983 J

200 kA

Rated Breaking Capacity at 500 VDC: 20000 A

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

048107.5HXLM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

KLDR07.5TXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7.5 A

End Cap

321.8 J

Nickel

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

0.406 in (10.3 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

1681750100

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

49 J

-40 °C (-40 °F)

1 kA

Bulk

0.465 in (11.8 mm)

0.15 in (3.8 mm)

20 ms

0.339 in (8.6 mm)

DIN

85 °C (185 °F)

Very Fast

032707.5ZXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

47 J

-40 °C (-40 °F)

Silver

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e4

Micro

0.311 in (7.9 mm)

125 °C (257 °F)

AGC7.5

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

7.5 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

032707.5YX2T

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

47 J

-40 °C (-40 °F)

Tin

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

e3

32 V

Micro

0.602 in (15.3 mm)

125 °C (257 °F)

FLNR7.5ID

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

7.5 A

End Cap

200 kA

0.563 in (14.3 mm)

Indicator

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CSA; UL

Time Delay

KLDR07.5

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

7.5 A

End Cap

321.8 J

200 kA

12 s

Rated Breaking Capacity at 300 VDC: 20000 A

0.406 in (10.3 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

MIN7.5

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

68 J

-40 °C (-40 °F)

1 kA

30 ms

Box

0.429 in (10.9 mm)

0.15 in (3.8 mm)

0.346 in (8.8 mm)

UL

125 °C (257 °F)

SFE7.5

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

7.5 A

End Cap

0.25 in (6.35 mm)

32 V

0.875 in (22.225 mm)

044607.5

Littelfuse

Electric Fuse

Surface Mount

350 V

125 V

7.5 A

Gull Wing

68 J

-40 °C (-40 °F)

Tin

100 A

Rated Breaking Capacity at 125 VDC: 50 A

Tape And Reel

0.43 in (10.92 mm)

0.345 in (8.76 mm)

e3

0.43 x 0.345 x 0.15 in (10.92 x 8.76 x 3.81 mm)

0.15 in (3.81 mm)

CSA; PSE; UL

125 °C (257 °F)

Fast

AGA7.5

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

7.5 A

End Cap

0.25 in (6.35 mm)

32 V

1AG

0.625 in (15.875 mm)

048107.5VXLM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

300 A

5 m

0.839 in (21.3 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

0309612H

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

7.5 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

0.875 in (22.22 mm)

Normal

048107.5HM

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

166.7000.475.2

Littelfuse

Electric Fuse

7.5 A

Tab/Blade

Matte Tin

1 kA

44.5

0.748 in (19 mm)

0.197 in (5 mm)

Supplemental

e3

80 V

ATO

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

CSA; UL

Time Lag

048107.5VMP

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

121 J

-55 °C (-67 °F)

300 A

5 m

0.701 in (17.8 mm)

0.228 in (5.8 mm)

125 V

Alarm; Indicator

0.772 in (19.6 mm)

CSA; UL

125 °C (257 °F)

Fast

048107.5

Littelfuse

Electric Fuse

Inline/Holder

125 V

125 V

7.5 A

End Cap

42.8 J

-55 °C (-67 °F)

Tin/Lead

300 A

481

Rated Breaking Capacity at 125 VDC: 300 A

Box

e0

Alarm

CSA; UL

125 °C (257 °F)

089107.5U

Littelfuse

Electric Fuse

Inline/Holder

58 V

7.5 A

Tab/Blade

53 J

-40 °C (-40 °F)

1 kA

30 ms

Bulk

0.429 in (10.9 mm)

0.15 in (3.8 mm)

58 V

Mini

0.299 in (7.6 mm)

ISO

125 °C (257 °F)

028707.5PXS

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

-40 °C (-40 °F)

Tin

1 kA

80 ms

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

CSA; UL

125 °C (257 °F)

142.6185.475.2

Littelfuse

Electric Fuse

Inline/Holder

58 V

7.5 A

Tab/Blade

60 J

Tin

Rated Breaking Capacity at 58 VDC: 1000 A

0.748 in (19 mm)

0.197 in (5 mm)

e3

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

125.6785.4757

Littelfuse

Electric Fuse

Inline/Holder

125 V

7.5 A

Tab/Blade

60 J

Silver

Rated Breaking Capacity at 125 VDC: 1000 A

0.469 in (11.9 mm)

0.15 in (3.8 mm)

e4

0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm)

0.339 in (8.6 mm)

UL

025707.5L

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

-40 °C (-40 °F)

Tin

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

0.74 in (18.8 mm)

UL

105 °C (221 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.