70 A Fuses 221

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LPJ-70SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

LPJ-70SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.126 in (28.6 mm)

J

600 V

Indicator

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

TCF70

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

-40 °C (-40 °F)

Tin

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

2.992 in (76 mm)

0.984 in (25 mm)

e3

Indicator

3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm)

1.26 in (32 mm)

CSA; UL

80 °C (176 °F)

Time Delay

SP/LPJ-70SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

e4

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

AJT70

Mersen S A

Electric Fuse

Inline/Holder

700 V

400 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 400 VDC: 100000 A

1.063 in (27 mm)

Indicator

1.142 x 2.638 in (29 x 67 mm)

4.606 in (117 mm)

Time Delay

MEV100A70-4Y

Mersen S A

Electric Fuse

Inline/Holder

1 KV

70 A

Tab/Blade

100 kA

40 ms

Bulk

1 in (25.4 mm)

2.874 in (73 mm)

IATF 16949; UL

MEV100A70-4

Mersen S A

Electric Fuse

Inline/Holder

1 KV

70 A

Tab/Blade

100 kA

40 ms

Bulk

1 in (25.4 mm)

2.874 in (73 mm)

IATF 16949; UL

153.0020.5702

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

ECNR70

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

70 A

Tab/Blade

200 kA

Bulk

1.06 in (26.924 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

0TLS070.TXLR

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

153.5631.5701

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

22000

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

L70QS070.V

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

70 A

Tab/Blade

359 J

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 700 VDC: 50000 A

Box

1 in (25.4 mm)

2.875 in (73.03 mm)

CUL; UL

125 °C (257 °F)

Very Fast

0498070.SXT

Littelfuse

Electric Fuse

70 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Lag

JLLN070

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 0.843 in (20.6 x 21.4 mm)

2.157 in (54.8 mm)

CE; CSA; CUL; UL

Fast

JLLN070.V

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

0.811 in (20.6 mm)

300 V

2.157 in (54.8 mm)

CE; CSA; CUL; UL

Fast

LLSRK070ID

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

Indicator

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

SPFJ070.X

Littelfuse

Electric Fuse

Inline/Holder

1 KV

70 A

Tab/Blade

5.213 kJ

20 kA

8 m

Rated Breaking Capacity at 1000 VDC: 20000 A

Bulk

1.5 in (38.1 mm)

Midget

3.012 in (76.5 mm)

CE; IEC; UL

FLSR070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

200 kA

FLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

SHEV070.ZXBD

Littelfuse

Electric Fuse

Inline/Holder

450 V

70 A

Tab/Blade

-40 °C (-40 °F)

10 kA

50 ms

0.787 in (20 mm)

450 V

1.642 in (41.7 mm)

125 °C (257 °F)

Time Delay

LA70QS70-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

70 A

Tab/Blade

1.8 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

0TLS070.TXL

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

0293070.H

Littelfuse

Electric Fuse

70 A

-40 °C (-40 °F)

Silver

0.906 in (23 mm)

0.646 in (16.4 mm)

e4

32 V

0.906 x 0.646 x 1.205 in (23 x 16.4 x 30.6 mm)

1.205 in (30.6 mm)

125 °C (257 °F)

4998070.M-1M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

70 A

Tab/Blade

10.9 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

153.0010.5702

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

CBO070

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

10 kA

0.812 in (20.62 mm)

0.812 x 1.625 in (20.62 x 41.28 mm)

1.623 in (41.23 mm)

Fast

RLN070

Littelfuse

Electric Fuse

Inline/Holder

250 V

70 A

Tab/Blade

10 kA

1.063 in (27 mm)

5.874 in (149.2 mm)

CE; CSA; UL

0498070.MX1M6-CN

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

24 kJ

-40 °C (-40 °F)

2 kA

Bulk

0.63 in (16 mm)

0.472 in (12 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

Time Delay

0295070.MXJ

Littelfuse

Electric Fuse

70 A

-40 °C (-40 °F)

0.898 in (22.8 mm)

0.638 in (16.2 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

0293070.U

Littelfuse

Electric Fuse

70 A

-40 °C (-40 °F)

Silver

0.906 in (23 mm)

0.646 in (16.4 mm)

e4

32 V

0.906 x 0.646 x 1.205 in (23 x 16.4 x 30.6 mm)

1.205 in (30.6 mm)

125 °C (257 °F)

JLLS070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

0.811 in (20.6 mm)

0.811 x 1.642 in (20.6 x 41.7 mm)

1.642 in (41.7 mm)

CSA; UL

Fast

KLSR070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

KLSR

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

7.874 in (200 mm)

CSA; UL

Fast

70-2R-1BI-8.25

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

70 A

Tab/Blade

190 A

Rated Breaking Capacity=190A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

153.5631.5702

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

22 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

22000

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

LLSRK070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 7.874 in (33.3 x 200 mm)

7.874 in (200 mm)

CSA; UL

Time Delay

L50S70

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

70 A

Tab/Blade

200 kA

Rated Breaking Capacity at 450 VDC: 20000 A

1 in (25.4 mm)

1 x 2.126 in (25.4 x 54 mm)

2.126 in (54 mm)

CSA; UL

Fast

299070

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

6.9 kJ

Silver

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

UL

Slow

0294070.MXJ

Littelfuse

Electric Fuse

70 A

-40 °C (-40 °F)

0.906 in (23 mm)

0.646 in (16.4 mm)

32 V

0.906 x 0.646 x 0.996 in (23 x 16.4 x 25.3 mm)

0.996 in (25.3 mm)

125 °C (257 °F)

4998070.M-M6

Littelfuse

Electric Fuse

Inline/Holder

70 V

70 A

Tab/Blade

10.9 kJ

-40 °C (-40 °F)

2.5 kA

70 ms

0.63 in (16 mm)

0.496 in (12.6 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

156.5611.5701

Littelfuse

Electric Fuse

Inline/Holder

36 V

70 A

Tab/Blade

-40 °C (-40 °F)

375 A

1 m

Bulk

0.709 in (18 mm)

0.551 in (14 mm)

0.256 in (6.5 mm)

125 °C (257 °F)

70-2R-1IB-5.5

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

70 A

Tab/Blade

170 A

Rated Breaking Capacity=170A-80000A

3 in (76.2 mm)

Indicator

3 x 18 in (76.2 x 457.2 mm)

18 in (457.2 mm)

Medium

LCL2R

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

70 A

End Cap

170 A

LCL

Rated Breaking Capacity=170A-80000A

3 in (76.2 mm)

3 x 15.875 in (76.2 x 403.23 mm)

15.875 in (403.23 mm)

Medium

TLS-LS070

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

End Cap

Silver

Rated Breaking Capacity at 170 VDC: 100000

0.562 in (14.27 mm)

e4

0.562 x 0.944 in (14.27 x 23.98 mm)

0.944 in (23.98 mm)

UL

TLS070LS

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

Silver

100 kA

0.563 in (14.3 mm)

e4

0.563 x 0.88 in (14.3 x 22.35 mm)

0.88 in (22.35 mm)

CE; UL

0TLS070.TXLB

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

100 kA

Bulk

0.563 in (14.3 mm)

170 V

0.563 x 0.877 in (14.3 x 22.27 mm)

0.877 in (22.28 mm)

CUL; IEC; TUV; UL

L17T70

Littelfuse

Electric Fuse

Inline/Holder

170 V

70 A

Tab/Blade

Rated Breaking Capacity at 170 VDC: 100000 A

1 in (25.4 mm)

1 x 1.157 in (25.4 x 29.4 mm)

1.157 in (29.4 mm)

CSA; UL

Very Fast

LGD070

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

70 A

End Cap

200 kA

LGD

Rated Breaking Capacity at 300 VDC: 20000 A

Time Delay

LA30QS70-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

70 A

Tab/Blade

1.6 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.22 in (31 mm)

1.22 x 1.63 in (31 x 41.4 mm)

1.63 in (41.4 mm)

UL

Very Fast

70-2R-1C-5.5X

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

70 A

End Cap

170 A

15 s

3 in (76.2 mm)

Striker

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

40 °C (104 °F)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.