Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
J |
600 V |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
1.126 in (28.6 mm) |
J |
600 V |
Indicator |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
e3 |
Indicator |
3.01 x 1 x 1.26 in (76.45 x 25.4 x 32 mm) |
1.26 in (32 mm) |
CSA; UL |
80 °C (176 °F) |
Time Delay |
||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
Silver |
300 kA |
Rated Breaking Capacity at 300 VDC: 100000 A |
1.126 in (28.6 mm) |
e4 |
1.126 x 2.626 in (28.6 x 66.7 mm) |
2.626 in (66.7 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
700 V |
400 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 400 VDC: 100000 A |
1.063 in (27 mm) |
Indicator |
1.142 x 2.638 in (29 x 67 mm) |
4.606 in (117 mm) |
Time Delay |
|||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
70 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
1 KV |
70 A |
Tab/Blade |
100 kA |
40 ms |
Bulk |
1 in (25.4 mm) |
2.874 in (73 mm) |
IATF 16949; UL |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
70 A |
Tab/Blade |
200 kA |
Bulk |
1.06 in (26.924 mm) |
5.88 in (149.352 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
22000 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
70 A |
Tab/Blade |
359 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 700 VDC: 50000 A |
Box |
1 in (25.4 mm) |
2.875 in (73.03 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
70 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
0.811 in (20.6 mm) |
0.811 x 0.843 in (20.6 x 21.4 mm) |
2.157 in (54.8 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
0.811 in (20.6 mm) |
300 V |
2.157 in (54.8 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
Indicator |
1.311 x 7.874 in (33.3 x 200 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
70 A |
Tab/Blade |
5.213 kJ |
20 kA |
8 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
200 kA |
FLSR |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
450 V |
70 A |
Tab/Blade |
-40 °C (-40 °F) |
10 kA |
50 ms |
0.787 in (20 mm) |
450 V |
1.642 in (41.7 mm) |
125 °C (257 °F) |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
70 A |
Tab/Blade |
1.8 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
1 in (25.4 mm) |
1 x 2.874 in (25.4 x 73 mm) |
2.874 in (73 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
70 A |
-40 °C (-40 °F) |
Silver |
0.906 in (23 mm) |
0.646 in (16.4 mm) |
e4 |
32 V |
0.906 x 0.646 x 1.205 in (23 x 16.4 x 30.6 mm) |
1.205 in (30.6 mm) |
125 °C (257 °F) |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
70 A |
Tab/Blade |
10.9 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
0.63 in (16 mm) |
0.472 in (12 mm) |
32 V |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
10 kA |
0.812 in (20.62 mm) |
0.812 x 1.625 in (20.62 x 41.28 mm) |
1.623 in (41.23 mm) |
Fast |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
70 A |
Tab/Blade |
10 kA |
1.063 in (27 mm) |
5.874 in (149.2 mm) |
CE; CSA; UL |
||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
24 kJ |
-40 °C (-40 °F) |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
70 A |
-40 °C (-40 °F) |
0.898 in (22.8 mm) |
0.638 in (16.2 mm) |
32 V |
0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm) |
0.846 in (21.5 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
70 A |
-40 °C (-40 °F) |
Silver |
0.906 in (23 mm) |
0.646 in (16.4 mm) |
e4 |
32 V |
0.906 x 0.646 x 1.205 in (23 x 16.4 x 30.6 mm) |
1.205 in (30.6 mm) |
125 °C (257 °F) |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
0.811 x 1.642 in (20.6 x 41.7 mm) |
1.642 in (41.7 mm) |
CSA; UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
200 kA |
KLSR |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
7.874 in (200 mm) |
CSA; UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
8.25 KV |
70 A |
Tab/Blade |
190 A |
Rated Breaking Capacity=190A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 18 in (76.2 x 457.2 mm) |
18 in (457.2 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
22000 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.311 in (33.3 mm) |
1.311 x 7.874 in (33.3 x 200 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 450 VDC: 20000 A |
1 in (25.4 mm) |
1 x 2.126 in (25.4 x 54 mm) |
2.126 in (54 mm) |
CSA; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
6.9 kJ |
Silver |
1 kA |
Rated Breaking Capacity at 32 VDC: 1000 A |
1.15 in (29.21 mm) |
0.348 in (8.85 mm) |
e4 |
1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm) |
0.85 in (21.59 mm) |
UL |
Slow |
||||||||||||||
|
Littelfuse |
Electric Fuse |
70 A |
-40 °C (-40 °F) |
0.906 in (23 mm) |
0.646 in (16.4 mm) |
32 V |
0.906 x 0.646 x 0.996 in (23 x 16.4 x 25.3 mm) |
0.996 in (25.3 mm) |
125 °C (257 °F) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
70 A |
Tab/Blade |
10.9 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
36 V |
70 A |
Tab/Blade |
-40 °C (-40 °F) |
375 A |
1 m |
Bulk |
0.709 in (18 mm) |
0.551 in (14 mm) |
0.256 in (6.5 mm) |
125 °C (257 °F) |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
70 A |
Tab/Blade |
170 A |
Rated Breaking Capacity=170A-80000A |
3 in (76.2 mm) |
Indicator |
3 x 18 in (76.2 x 457.2 mm) |
18 in (457.2 mm) |
Medium |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
70 A |
End Cap |
170 A |
LCL |
Rated Breaking Capacity=170A-80000A |
3 in (76.2 mm) |
3 x 15.875 in (76.2 x 403.23 mm) |
15.875 in (403.23 mm) |
Medium |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
End Cap |
Silver |
Rated Breaking Capacity at 170 VDC: 100000 |
0.562 in (14.27 mm) |
e4 |
0.562 x 0.944 in (14.27 x 23.98 mm) |
0.944 in (23.98 mm) |
UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
Silver |
100 kA |
0.563 in (14.3 mm) |
e4 |
0.563 x 0.88 in (14.3 x 22.35 mm) |
0.88 in (22.35 mm) |
CE; UL |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
170 V |
0.563 x 0.877 in (14.3 x 22.27 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
Rated Breaking Capacity at 170 VDC: 100000 A |
1 in (25.4 mm) |
1 x 1.157 in (25.4 x 29.4 mm) |
1.157 in (29.4 mm) |
CSA; UL |
Very Fast |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
70 A |
End Cap |
200 kA |
LGD |
Rated Breaking Capacity at 300 VDC: 20000 A |
Time Delay |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
300 V |
70 A |
Tab/Blade |
1.6 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.22 in (31 mm) |
1.22 x 1.63 in (31 x 41.4 mm) |
1.63 in (41.4 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
70 A |
End Cap |
170 A |
15 s |
3 in (76.2 mm) |
Striker |
3 x 17.875 in (76.2 x 454.03 mm) |
17.875 in (454.03 mm) |
40 °C (104 °F) |
Medium |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.